My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
>
Address Records
>
EVERGREEN WAY
>
4921
>
TROPICAL TAN
>
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2018 8:23:42 AM
Creation date
5/15/2018 8:23:38 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4921
Tenant Name
TROPICAL TAN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� -____ _.__ ___- -_ �_. --� Guide Specification for Page:11 <br /> �� <br /> York Sunline <br /> ELECTRICAL REQUIREMENTS <br /> All unit power wiring shall enter unit cabinet at a single <br /> factory provided location and be capable of side or <br /> bottom entry,to minimize roof penetrations and avoid <br /> unit field modifications. Separate side and bottom <br /> openings shall be provided for the control wiring. <br /> STANDARD LIMITED WARRANTIES <br /> • Compressor 5 Years <br /> • Heat Exchanger 10 Years <br /> • Electric Heat Element 5 Years <br /> • Other Parts 1 Year <br /> OPTIONAL OUTDOOR AIR <br /> • Economizer—Outdoor and return air dampers that <br /> are interlocked and positioned by a fully-modulating, <br /> spring return damper actuator. The maximum leakage <br /> rate for the outdoor air intake dampers shall not <br /> exceed 2%when dampers are fully closed and <br /> operating against a pressure differential of 0.5 IWG. <br /> A unit-mounted potentiometer shall be provided to <br /> adjust the outdoor and return air damper assembly to <br /> take in CFM of outdoor air to meet the minimum <br /> ventilation requirement of the conditioned space <br /> during normal operation. During economizer <br /> operation, a mixed-air temperature control shall <br /> modulate the outdoor and return air damper <br /> assembly to prevent the supply air temperature from <br /> dropping below 55°F.The outdoor intake opening <br /> shall be covered with a rain hood that matches the <br /> exterior of the unit. Water eliminator/filters shall be <br /> provided. Simultaneous economizer/compressor <br /> operation is also possible. Dampers shall fully close <br /> on power loss. <br /> ADDITIONAL FACTORY INSTALLED OPTIONS <br /> • BAS Controls <br /> FIELD INSTALLED OPTIONS <br /> • Barometric Relief Damper—This damper accessory <br /> can be used to relieve internal building air pressure <br /> on units with an economizer without power exhaust. <br /> This accessory includes a rain hood, a bird screen <br /> and a fully assembled damper. With bottom duct <br /> connections, the damper should be mounted over the <br /> opening in the return air panel.With horizontal <br /> ductwork,the accessory should be mounted on the <br /> return air duct. <br /> Unitary Sales Tool v1.5.9.0 Information is subject to change without notice.Check local codes. Printed 03/30Y2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.