My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
>
Address Records
>
EVERGREEN WAY
>
4921
>
TROPICAL TAN
>
4921 EVERGREEN WAY TROPICAL TAN 2018-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2018 8:23:42 AM
Creation date
5/15/2018 8:23:38 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4921
Tenant Name
TROPICAL TAN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> �� �_�,�� <br /> 530.18-TG1Y(295) <br /> � O <br /> ��� SINGLE PACKAGE <br /> e,� AIR-COOLED <br /> � '�� AIR CONDITIONERS <br /> • � D3CE 036,048,060&D10E 072 <br /> D6CG 036, 048, 060&D1CG 072 <br /> �� •• 3,4 AND 5 NOMINAL TONS(10 SEER) <br /> • �� <br /> AND 6 NOMINAL TONS(9 EER) <br /> a <br /> ��'� �� � � SUNLINE 2000TM <br /> �•" DCG MODEL <br /> SHOWN <br /> DESCRIPTION <br /> YORK Sunline 2000 units are convertible single package air duct covers from the outside of the unit and discard them. If a <br /> conditioners with a common cabinet and a common roof curb bottom supply / bottom retum is desired, you simply remove <br /> for the 3, 4, 5 and 6 ton sizes. The units were designed for the two knockout panels from the base of the unit and discard <br /> residential, light commercial and commercial applications. them. No panei cutting or swapping is required! Convertible <br /> They can easily be installed on a roof curb, siab, roof�ack or airFlow design allows maximum field flexibility and minimum <br /> frame. inventory. Economizers may be used on either bottom and side <br /> All units are self-contained and assembled on rigid full duct applications with no modifications required. <br /> perimeter base rails with fork lift slots on three sides and holes <br /> for overhead rigging. Every unit is completely piped, wired, FACTORY-INSTALLED OPTIONS - Economizers can be <br /> charged and tested at the factory to provide for a quick and installed at the factory.The economizers are shipped installed <br /> easy field installation. and wired.Only the rain hood needs to be field assembled and <br /> The units are available in coolin onl , and coolin with as �nstalled. Field labor dollars can be saved by having the <br /> 9 Y 9 9 components arrive already installed. <br /> heat. Electric heaters are available as field-installed <br /> accessories. Adjustable belt drive blowers are available on most models <br /> from the factory for complete airtlow flexibility. <br /> The cabinet is constructed of galvanized steel, painted with <br /> long lasting, durable, and aesthetically pleasing power paint. FIELD-INSTALLED ACCESSORIES - Accessories were <br /> Paint finish meets 750 hour salt spray tests per ASTM-B117 designed for quick and easy installation.The motorized damper <br /> standards. and economizers simply slide in, and electrical connections are <br /> made by modular plugs. Electric heaters mount easily, and <br /> All models include a 5-year limited warranty on compressors knockouts are provided in the internal partitions to connect the <br /> and electric heating elements, a 10-year limited warranty on elements to the control box single point kit. <br /> gas-fired heat exchangers and a 1-year limited warranty on all <br /> replacement parts. The 14"high roof curb is shipped knocked down.An insulated <br /> deck is not required because the bottom of the unit is insulated. <br /> FEATURES �oW ambient controls are available to provide stable unit <br /> COMMON FOOTPRINT/COMMON CABINET - All model operation at outdoor temperatures down to 0°F. <br /> sizes and configurations share a common cabinet and a Propane, high altitude and low NOx kits are also available to <br /> common roof curb.The installer has the flexibility ofsetting one cover all gas heating applications. <br /> curb and placing the proper tonnage unit on that curb after the <br /> internal load has been determined. He can even decide �N�DE RANGE OF INDOOR AIRFLOWS -All 3, 4 and 5-ton <br /> between gas or electric heat after the curb has been set. models operate over a wide range of design conditions with a <br /> 3-speed direct-drive fan motor.The 6-ton unit has a single speed <br /> HIGH EFFICIENCY-All units have a high cooling efficiency, direct-drive fan motor.Belt-drive blowers are also available on all <br /> and gas/electric models have a minimum AFUE of 80%.All 3,4 and 5-ton models and on 6 ton,3-phase models. <br /> efficiencies exceed legislated minimum levels and provide low <br /> operating costs. FULL PERIMETER BASE RAILS-The permanently attached <br /> base rails provide a solid foundation for the entire unit and <br /> CONVERTIBLE AIRFLOW DESIGN-Both the side and bottom protect the unit during shipment. The rails provide fork lift <br /> duct openings are covered when they leave the factory.If a side access from 3 sides, and rigging holes are also provided so <br /> supply/side return is desired, you simply remove the finro side that an overhead crane can be used to place fhe units on a roof. <br /> Cont'd. <br />
The URL can be used to link to this page
Your browser does not support the video tag.