My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10611 EVERGREEN WAY KLEIN HONDA 2022-10-27
>
Address Records
>
EVERGREEN WAY
>
10611
>
KLEIN HONDA
>
10611 EVERGREEN WAY KLEIN HONDA 2022-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2022 9:43:13 AM
Creation date
5/15/2018 10:51:20 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10611
Tenant Name
KLEIN HONDA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vertical Fenestratioi .'arget Area-Adjustment Ca( alations <br /> All projects utilizing the street level retail glazing exception and those sharing window allowance with street level projects must submit the Maximum <br /> Target Vertical Fenestration Calculation. <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is <br /> • <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration(exclude SLG) NW=Net above grade wall(excludes fenestration and doors.) <br /> SG=Exempt Single Glazing Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG Wall=Above-grade wall(exclude SLW) DR=Opaque doors <br /> SLW=Street level gross wall below ceiling SLG=Area of window in Street level qualified wall <br /> height and 20'per C402.3.1 SLT=Window area transferred to Street Level Retail wall from other areas <br /> Proposed Areas <br /> Vertical Fenestration(non-exempt)-> VF= 2662.0 <br /> Vertical Fenestration(exempt)-> SG= 61.. <br /> Opaque-> NW= 4520.0 DR= <br /> Street Level Retail->SLT= n/a <br /> Maximum Target Vertical Fenestration Calculation <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen.Area <br /> 7182.0 X 40.0% _ 100 = 2872.8 <br /> i <br /> Window area <br /> Base Target Vert. transferred to Street Maximum Target Gross Exterior AG Maximum Target <br /> Fen.Area Level Retail(SLT) Vert. Fen.Area Wall Vert.Fen% <br /> 2872.8 _ = 2872.8 ± 7182.0 = 40.0% <br /> Vertical Fenestration Component 'erformance Target Area Adjustment Calculation <br /> I otal vertical Delta Vertical Excess vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 2662.0 - 2872.8 = -210.8 II greater = <br /> -----1- -210.8 / Multiplier applied to all <br /> Total Vertical Excess Vertical / Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration IG/ Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> 2662.0 - = 2662.0 - 2662.0 = 1.00 calculate Target Vertical <br /> • Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> 4520.0 + = 4520.0 . 4520.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Tar et Areas UA calculateTarget Above- <br /> g Grade Wall Area <br /> Commercial <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame X = <br /> Metal frame,fixed 2822.0 X 1.00 = 2822.0 <br /> Metal frame,operable X = <br /> Metal frame,entrance door X <br /> Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame 4520.0 X 1.00 = 4520.0 target areas on ENV-UA <br /> Metal Building 3588.0 X 1.00 = 3588.0 <br /> Wood I Other frame X = <br /> = <br /> Mass X <br /> Mass Transfer Deck X = <br /> Group R Wood/Other frame X _ <br /> Sum of Proposed 10930.0 Sum of Target 10930.0 Sum of target above-grade <br /> wall and vertical <br /> fenestration areas are <br /> Target Areas -SHGC x A calculated to equal the <br /> sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 1917.0 X 1.00 = 1917.0 <br /> 0.25PF<0.5 X = <br /> PF>_0.5 X = SHGC target areas in <br /> North Vertical Fenestration shaded boxes are applied <br /> to target areas on ENV- <br /> PF<0.2 745.0 X 1.00 = 745.0 SHGC <br /> 0.25PF<0.5 X = <br /> PF 0.5 X = <br />
The URL can be used to link to this page
Your browser does not support the video tag.