My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10611 EVERGREEN WAY KLEIN HONDA 2022-10-27
>
Address Records
>
EVERGREEN WAY
>
10611
>
KLEIN HONDA
>
10611 EVERGREEN WAY KLEIN HONDA 2022-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2022 9:43:13 AM
Creation date
5/15/2018 10:51:20 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10611
Tenant Name
KLEIN HONDA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SHGC Calculation • ENV-SHGC <br /> 2015 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3,&R4 over 3 stories and all R1 Revised Feb 2017 <br /> Project Title: Klein Honda Addition Date 10/25/2017 <br /> %• 37.1% Max.Target: 40% For SDCI Use <br /> Fenestration Area asgross above-grade wall area <br /> Skylight Area as%gross roof area Max.Target: 5% <br /> Vertical Fenestration Alternates: 50%Conditioned Floor Area in Daylight Zone <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating,or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included <br /> in this worksheet.Enter target SHGC values for this fenestration under proposed SHGC,so it <br /> is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x F SHGC x Area(A)= SHGC x A <br /> 0.32 <br /> SHGC 0.32 <br /> Skylight Totals <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> Aluminum Table C402.1.3 I 0.40 1917 767 PF<0.2 ' 0.35 1917 671.0 <br /> 0.2_<PF<0.5 0.45 <br /> PF>_0.5 0.60 <br /> • <br /> ++If projection factor(PF)credits are <br /> applied to the proposed design, Target <br /> SHGC will sum fenestration area by PF <br /> category. <br /> +lf PF credit is applied then vertical fenestration Non-North Window Totals 1917.0 766.8 1917.0 671.0 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> Aluminum Table C402.1.3 I 0.40 745 298 PF<0,2 0.53 745 394.9 <br /> 0.25PF<0.5 0.58 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design, Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals 745.0 298.0 745.0 394.9 <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 2662.0 1064.8 2662.0 1065.8 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br /> D <br />
The URL can be used to link to this page
Your browser does not support the video tag.