Laserfiche WebLink
� . <br /> 2813 Rockefeller Ave. Everett,WA 98201• ph:425.317.8017 •fax:425.317.8489 <br /> City of Everett <br /> Public Services Department <br /> 3200 Cedar Street <br /> Everett,WA 98201 <br /> 11.15.2016 �;��' ����� �,� ,�;� ' <br /> .' r� � � <br /> Re: PLAN CHECK NUMBER: C1609-027 �"S\ ��� � 5 2n�, <br /> PROJECT NAME: Sawiris Residence �; <br /> PROJECT ADDRESS: 2107 Grand Ave. .�•,;� �� E\I�RETT <br /> Building Division <br /> 1. The proposed Bedroom does not meet the minimum area for habitable space per IRC section <br /> R304. <br /> �;t�sponse: Bedroorn sGuare Footag� has r�een revi5eci on prop�scci tloor plan to be 70 sq. tt. on <br /> ��.����� pl�n note 3 in sheet A-2.1 per IRC section R304. <br /> 2. Specify the U-Value for all new fenestration on the construction drawings (you have chosen to use <br /> option 1a for your energy credits, notations need to reflect those values on the plans). <br /> F:"�, . ��. J�1.'�:L ��-�.� SiiO'.,.� l i, l, ,-�J. ; I�� � I� f'�_ .. I_ i�;'SU_ ��. �' ._ _ �I , . �" 'E' <br /> a� �� -� r� Information. Additionally, Added U values on the window schedule sheet A-2.1 for the new <br /> V� window (U=.28) to reflect the val�ies per WSEC Table 406.2, option 1a. <br /> 3. Specify the pitch of the roof at the proposed laundry room addition. 3-tab composition roofing <br /> requires a minimum pitch of two units vertical in 12 units horizontal per section R905.2.2 IRC,the <br /> plans show%z unit vertical in 12 units horizontal. <br /> ��_`,n � �15z�: � r_��i � �f �1, ,�� � ir�� � I,� ��� ii � ' y�_ �� ���� il��- , .� l"�i�� �, <br /> (VIF) of the existing roof over the dining room. Changes made to proposed roof plan on sheet A- <br /> 2.2 to reflect thi5. <br /> 4. Provide R-10 rigid insulation at all headers in bearing exterior walls per Table R402.1.1 of the <br /> WSEC. Show on plans. <br /> „ . � ' �fl=:�: I _ rr,l.li,'�Iri;�i �,. �CilC�il� ���,ir. �1 �, `� - � ! c _ � . L� � Li iii_� � Ir_i. <br /> i���+s��il ii_ion ��t ���II I,r�ad�rs in ,�.�a�ing e�L:=rior walls per�1�StC Table F=;-02."i _! , <br /> 5. Section AA and Section CC on sheet A-3.2 show similar construction in the Dining Room and the <br /> Laundry Room, while Wall Section 1 on Sheet A-3.3 shows something completely different in the <br /> Laundry Room.The section drawing at the laundry room shows the roof of the addition supported <br /> by the existing partial height exterior wall at the house. Please clarify the actual construction at <br /> this location. Provide ledger detail if applicable (section and elevation of ledger) showing all <br /> connectors. <br /> RE�sponse: Both s;�cCions sho���,� ihe correct cor�struction at this location. The wall seciion 7_ or� <br /> sheet A-3.3 should be showing the south wall of the proposed laundry room addition. Notes have <br /> been added to sheet A-2.1, A-2.2, and A-3.1 to reflect this change of location. Detail 3: Wall <br /> section at Roof on sheet A-3.3 has been amended to clarify ledger condition at east wall of <br /> laundry room addition as shown on the sections. <br /> 1 � Page <br />