Laserfiche WebLink
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: EVERETT 76 Date 4/3/17 <br /> Calculation C addition O Addition For Building Department Use <br /> stand alone +existing <br /> Area NOTE <br /> ('1Spaces where<50%of (")Spaces where a 50%of O <br /> uminaires are replaced \--luminaires are replaced <br /> LPA (tandard additional Efficiency Package Option O <br /> Calculation 0406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"OTE' <br /> Location(plan#, L'e""19 Gross Interior Allowed Watts Allowed <br /> room#) Space Type HeightNOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> A431/101 Sales area 780 1.270 991 <br /> A431/102 Restroom:all other 51 0.780 40 <br /> A431/103 Storage room 170 0.500 85 <br /> Total Area 1001 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> rtakenta <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE Allowed Watts 1116 <br /> Proposed Lighting Wattage NOTE' <br /> Location(plan#, Number of vvaust Watts <br /> room#) Fixture Description NOTE 4.5.6 Fixtures Fixture NOTE 7 ,�.4 (€,: " ^vi Proposed <br /> A431/101 LITHONIA/2GTL4 LP840(15 Existing+1 New) 16 35 xk 560 <br /> A431/102 LITHONIA/85BEMW 30K(1 New) 1 12 z 12 <br /> A431/103 STACO 90445(2 Existing) 2 9 18 <br /> r z <br /> yi 2 <br /> C c <br /> i <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 590 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g.T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4,1,note exception number and leave Waits/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts4ineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross Interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br />