Laserfiche WebLink
WALL, FLOOR, CEILING TYPE SCHEDULES DOOR SCHEDULE <br /> DOOR LOCATION SIZE (WXH) TYPE OPPERATION MATERIAL QTY AREA(SF) U-VALUE SHGC HARDWARE REMARKS NOTES � � � <br /> _ __� 'I 2X41NTERIOR WALL, TYPICAL O1 MAIN ENTRY 3'-0"X 7'-0" EXTERIOR SWING WOOD/GLASS 1 21 SF - - EXISTING EXISTING DOOR 7,9,10 <br /> �-~-~ , <br /> �. <br /> �-.,'-� <br /> l��r------��- _ 5/8" GWB 2� BACK DOOR 3'-0"X 7'-0" EXTERIOR SWING STEEL 1 21 SF - - EXISTING EXISTING DOOR 7,9 � <br /> _ ~f _�J-` (WATER RESISTIVE BOARD � WET LOCATIONS) � <br /> " -� ~ 3O WOMENS BATH 3'-0"X 7'-0" INTERIOR SWING WOOD 1 21 SF - - T.B.D. EXISTING DOOR 1,2,3,4,6,7 Pierce Design <br /> yr� "' ____ - -- - 2X WOOD STUD FRAMfNG, Zxa u.N.o. 2300 W Commodore Wa <br /> Y <br /> - _ __ - --- (VERIFY WITH PLANS) 4� MENS BATH 3'-0"X 7'-0" INTERIOR SWING WOOD 1 21 SF - - T.B.D. EXISTING DOOR 1,2,3,4,6,7 Suite 201 <br /> ACOUSTICAL BATT tNSULATION,AS REQUIRED PER Seattte, WA 98199 <br /> PLAN O PREP AREA 3'-2"X 7'-0" INTERIOR SWING WOOD 1 21 SF - - T.B.D. I NEW DOOR 1,2,3,4,6,7 . <br /> 5/8" GVVB - <br /> ���� <br /> (WATER RESISTIVE BOARD cLD WET LOCATIONS) DOOR SCHEDULE NOTES: <br /> 1 <br /> Project Contact <br /> 1. ALL DOOR LEAVES TO BE 1-3/4°THICK UNLESS OTHERWISE NOTED Wesley Pierce <br /> 2. FEILD VERIFY ROUGH OPENINGS PRIOR TO ORDERING DOORS wes @wespierce.COCTt <br /> 3. SHOP DRAWINGS TO BE REVIEWED AND APPROVED PRIOR TO PRODUCTION <br /> 4. HARDWARE TO BE SELECTED BY OWNER Tel: (206) 792-9396 <br /> 5. SELF CLOSING <br /> ,�.,,--= 2 2X6 INTERIOR WALL, TYPICAL 6, pR��iq�v� p�K <br /> 7. ADA COMPLIANT- OPERABLE PARTS SHALL BE OPERABLE W/ONE HAND, NOT REQUIRE TIGHT GRASPING, <br /> �� PINCHfNG OR TWISTING OF THE WRIST(NO KNOBS) FORCE REQ'D TOACTIVATE, 5 LBS MAX. 15"-48" HT RANGE. <br /> 8. LVWf'�tLJ Q <br /> -'` /^ 5/8" GWB 9. DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS <br /> _�.,_`- __:.----�`` (WATER RESISTIVE BOARD LOCATIONS) 10. SAFETY GLAZING <br /> ��-----��� _--- --- 2X6 WOOD STUD FRAMING, 2X4 U.N.O. <br /> =�, �..--�~"" _ __-- --- (VERIFY WITH PLANS) <br /> _- - -- ACOUSTICAL BATT fNSULATION,AS REQUIRED PER VERTICAL FENESTRATION SCHEDULE <br /> PLAN <br /> PROJECT ADDRESS <br /> WINDOW LOCATION MANUFACTURER MODEL NO. TYPE SIZE (WXH) QTY AREA(SF) U-VALUE SHGC NFRC-CPD REMARKS NOTES 2927 Wetmore Avenue <br /> 5/8" GWB <br /> Everett, WA 98201 <br /> (WATER RESISTIVE BOARD c� WET LOCATIONS) 1 WEST ELEVATION EXISTING NR FIXED +/- 4'-6"X 2'-2" 1 +1- 6.7 SF - - _ <br /> 2 ENTRY FOYER EXISTING NA FIXED/AWNING +/- 4'-6"X 7'-0" 1 +/- 31.5 SF - - _ g <br /> � <br /> 3 WEST ELEVATION EXISTING NA FIXED +/- 4'-6"X 2'-2" 1 +l-6.7 SF - _ _ x��r <br /> ..._------- '�Y 3 2X_ INTERIOR WALL 4 WEST ELEVATION EXISTING NA FIXED/AWNING +/-4'-6"X T-0" 1 +/- 31.5 SF <br /> �--�-r""��„ �''��: - - - <br /> �.� .�-- <br /> � -._ �' �.��� �=--r �^-~�~�-- 5 WEST ELEVATION EXISTING NA FIXED +/-4'-6"X 2'-2" 1 +t-6.7 SF - - _ <br /> x. <br /> � �----."' ,. / 5/8° GVVB <br /> ��°��k� ��« �'� �~ �� (WATER RESISTIVE BOARD cLD WET LOCATIONS) 6 WEST ELEVATtON EXISTING NA FIXED/AWNING +/- 4'-6"X T-0" 1 +/- 31.5 SF <br /> � ��.; ._.--- ~ � - ----` - - - <br /> `� - -- 2X_FLAT STUD FRAMING, 2X4 U.N.O. 7 WEST ELEVATION EXISTING NA FIXED + - °_ � �� + _ W <br /> '�" � � _- -- ----- (VERIFY WITH PLANS) / 4 6"X 2-2 1 / 6.7 SF - - - <br /> _ .�;�` : __ - --� _ <br /> - - EXISTING BRICK WALL 8 WEST ELEVATION EXISTING NA FIXED/AWNING +/- 4'-6"X 7'-0" 1 +!- 31.5 SF <br /> i - - - <br /> 8 EAST ELEVATION EXISTING AWNING +/- 3'-0"X 2'-0" 1 +/-6.0 SF - - _ - <br /> �� <br /> 10 EAST ELEVATION EXISTING AWNING +/- 3'-0"X 2'-0" 1 +/-6.0 SF - - _ <br /> � <br /> TOTALS +/- 164.8 SF - - <br /> � <br /> VERTICAL FENESTRATION NC�TES: <br /> t� 2X_ INTERIOR CEILING 1. FEILD VERIFY ROUGH OPENINGS PRIOR TO ORDERING DOORS W <br /> " 2. SHOP DRAWINGS TO BE REVIEWED AND APPROVED PRIOR TO PRODUCTION <br /> _,. <br /> 4�""�� �v � 3. SAFETY GLAZING <br /> � � <br /> `�� 5/8" GWB <br /> �� (WATER RESISTIVE BOARD @ WET LOCATIONS) <br /> 2X6 WOOD STUD FRAMING � <br /> _..---.r='� ACOUSTICAL BATT INSULATION,AS REQUIRED PER FINISH SCHEDULE <br /> _-�""� PLAN <br /> �-�""�f ROC?M No. ROOM NAME FLOOR CEILING NORTH WALL EAS7 WALL SOUTH WALL WEST WALL NOTES <br /> ff�---��-� 3/4" PLYWOOD ON TOP <br /> 100 CAFE CONCRETE-1, TILE-1 WOOD-1 BRICK-1 PAINT-1, PAINT-2 BRICK-1, TILE-2 PAINT-2 8 <br /> 101 COFFEE BAR CONCRETE-1 WOOD-2 NA NA TILE-2, BRICK-1 NA 3,4,5,6,7,11 <br /> 102 PREPAREA CONCRETE-1 PAINT-1 TILE-2 TILE-2 TILE-2 TILE-2 1 <br /> 103 HALLWAY CONCRETE-1 PAINT-1 BRICK-1 PAINT-2 NA PAINT-1 <br /> ISSUE <br /> 104 ADA WOMENS BATH TILE-3 PAINT-2 PAINT-2 PAINT-2 PAINT-2 PAINT-2 2,12 December 16, 2016 <br /> 105 ADA MENS BATH TILE-3 PAINT-2 BRICK-1 PAINT-2 PAINT-2 PAINT-2 2,12 PHASE <br /> Permit Documents <br /> FINISH SCHEDULE LEGEND: FINISH SCHEDULE NOTES: <br /> CONCRETE-1 (E) CONCRETE TO REMAIN (STAINED/SEALED) 1. 6"RUBBER BASE <br /> A NT-1 PAINT ON GWB <br /> 2. 6"TILE BASE REV. DATE REMARKS , <br /> PAINT 2 PAINT ON (E) GWB 3. TILE AT BACKBAR WALL 7 2-14-2017 BLDNG CORRECTIONS <br /> WOOD-1 (E) WOOD ROOF 7RUSS AND CEILING JOISTS TO REMAIN 4. P-LAM � BACKBAR PREP COUNTER <br /> WOOD-2 (E) WOOD CEILING JOISTS `SMOOTH & EASILY CLEANABLE' S. S7AINLESS STEEL cLD ISLAND COUNTER <br /> TILE-1 CERAMIC TILE OVER SUBFLOOR 6. STONE cLD BAR TOP <br /> TILE-2 CERAMIC TILE OVER GWB TILE BACKER BOARD 7. WOOD, SEALED @ HIGH BAR COUNTER <br /> TILE-3 (E}TILE TO REMAIN 8. WOOD, SEALED cGD WALL BAR <br /> BRICK-1 (E) BRICK WALL TO REMAIN 9. PREP AREA LIGHTS TO HAVE A SHEILD <br /> 10. SHELVING PER EQUIPMENT SCHEDULE <br /> 11. CABINET, P-LAM OR WOOD <br /> 12. P-LAM WAINSCOT <br /> WI N DOW, <br /> DOOR, FINISH <br /> SCHEDULES <br /> ■ <br />