Laserfiche WebLink
� � � <br /> � � -4--2x6 TREATED TIMBER <br /> E� <br /> EXISTING CONCRETE BUILDING—�- � �t�.;7.. . ,�,,,, EXISTING CONCRETE WALL <br /> WALL TO BE PROTECTED � 2X4 TREATED TIMBER <br /> 6 ;�..�, ` <br /> - 5'-0" CAULK BETWEEN DECK AND CONCRETE <br /> SS #10 SCREWS, TYP <br /> z <br /> � 4X4 GUARD POST � <br /> @ 4'-0" O.C. <br /> N <br /> I ( <br /> D <br /> I ( -—-—- --------------—-�, <br /> 5/8"� GALVANIZED � _ � ANCHOR <br /> S TE E L E P 0 X Y � ----------�___---__.__,,: <br /> ;' <br /> � I ANCHORS <br /> ;.� 2X8 TREATED TIMBER DECKING W/WASHERS, @ � <br /> II @ 45°, ATTACH WITH (2) MAX 2'-0" O.C. � <br /> STAINLESS STEEL #10 SCREWS u�,�u�,u��«m.� 2X4 TREATED TIMBER ATTACH TO <br /> A T E A C H J 01 N T S TR I N G E R ��,rn�:�,:.�,,,.�;,:7,. � ,_ __---------------------�-. <br /> EVERY POST WITH (2) STAINLESS \; � ANCHOR <br /> ( I - ' <br /> 4X8 TREATED STEEL #10 SCREWS, TYP. ------- -------___ <br /> TIMBER JOIST 4" MIN. � <br /> I �_ <br /> � \ <br /> I ---------- �� ��l }� 7 STRINGER z <br /> I GALVANIZED JOIST HANGER, SIMPSON STRONG TIE � <br /> -- - - - / HGUS48 OR EQUAL INSTALLED AS SHOWN, TYP. - <br /> � N <br /> STAGGER ANCHOR BOLTS, MAX 2'-0" SPACING <br /> 4x8 TREATED � � TREATED TIMBER DECKING BETWEEN STAGGERED BOLTS, TYP. <br /> TIMBER RIM JOIST —�/�- GALVANIZED STEEL HOLD-DOWN ANCHOR, <br /> SIMPSON STRONG TIE HD3B OR EQUAL 7 DETAIL <br /> 4X8 TREATED 4X8 TREATED TIMBER LEDGER, FULL 2" MIN. LEDGER ATTACHMENT <br /> TIMBER STRINGERS LENGTH ATTACHED TO EXISTING TO CONCRETE WALL <br /> BUILDING WITH EPDXY ANCHORS <br /> E X f S TI N G 6 x 12 LE D G E R, ___________.____._____.________.____ ��i <br /> 0 3 6 <br /> PROTECT IN-PLACE SHIM WITH GALVANIZED PLATE --- --- - ----- °� ° � <br /> � <br /> BETWEEN TOP OF WALL AND WALKWAY 2-1 /2" MIN. � SCALE IN INCHES <br /> TO PROVIDE LEVEL SURFACE, NAIL <br /> SHIMS WITH MIN (4) 16d GALVANIZED - ---- ---- - -- - <br /> NAILS TO EXISTING TIMBER LAGGING <br /> �� � GUARD POST <br /> --♦—EXISTING TIMBER 2 MIN. STRINGER ALIGN GUARD POST AT I ''�� <br /> EXISTING 16x16—�► LAGGING WALL 4x8 TREATED STRINGER LOCATIONS ' ; RIM JOIST <br /> TIMBER WALER PROTECT-IN-PLACE TIMBER RIM JOIST M I N. (2) 5/8"� G A L V A N I Z E D S T E E L <br /> PROTECT IN-PLACE THROUGH-BOLTS AND WASHERS, TYP. � <br /> � <br /> 6 DETAIL <br /> - GUARD POST TO I ' �� � <br /> RIM JOIST � <br /> ; I <br /> 5 DETAIL o 6 � 2 ! ; ' <br /> � i <br /> 9 10 WALKWAY �; ' � <br /> SCALE IN INCHES � <br /> O REPLA 1 EMENT 2 Q- , -- , _.� <br /> � <br /> SCALE IN FEET �4X4 TREATED TIMBER POST GALVANIZED STEEL ANGLE, SIMPSON <br /> ���� <br /> GALVANIZED STEEL STRONG TIE ML26Z OR EQUAL <br /> EXISTING GROUND SURFACE � o�° ! GALVANIZED POST BASE SIMPSON HOLD-DOWN ANCHOR <br /> � <br /> c� � � ! STRONG TIE PB44 OR EQUAL <br /> ; � ' ° �----- -------------------- <br /> 12H• 1� ' <br /> . <br /> , ---------------------- <br /> - - - - - - _ - - � - � ' �_ � _ � - _ _ _ - _ _ _ - - <br /> � . <br /> �=� <br /> z --- ------------- ----- <br /> � <br /> QUIKRETE CONCRETE MIX OR EQUAL, N STRINGER <br /> � <br /> FOLLOW MANUFACTURER'S <br /> RECOMMENDATION FOR INSTALLATION <br /> GENERAL NOTES ; : ` - : <br /> �J(> >U�.�OuL��,�O � � �� �OC.�U`,<�C.��i��. >> <br /> : v�b�� u�� ��� ,'�o�� ��;:�< � 4 MiN. �RavE� 8 DETAIL <br /> 1 . ALL CONNECTIONS, BOLTS, NAILS, AND HARDWARE SHALL BE HOT DIPPED GALVANIZED STEEL, -'`���,?�-��;����;<���?-;����;-��,n,-�-�� � 9 10 GUARD POST <br /> ����� �.� � :_ _L_ <br /> _�_ .� _ <br /> UNLESS NOTED OTHERWISE. TO RIM JOIST <br /> 2. ALL SAWN LUMBER SHALL BE MINIMUM #1 WEST COAST DOUGLAS-FIR. ALL SAWN LUMBER <br /> SHALL BE INCISED AND PRESSURE-TREATED WITH ACZA TO 0.6 PCF IN ACCORDANCE WITH 18"b 0 3 6 <br /> AWPA STANDARD U1 , USE CATEGORY 4C. ALL CUTTING, DRILLING AND OTHER FABRICATION �O DETAIL SCA�E IN INCHES <br /> SHALL BE PERFORMED, UNLESS OTHERWISE APPROVED, PRIOR TO PRESSURE TREATING. ANY <br /> FIELD DRILLING OR OTHER DAMAGE TO THE PRESSURE TREATMENT SHALL BE FIELD REPAIRED 9 10 POST SUPPORT <br /> USING TWO HEAVY COATS OF COPPER NAPTHENATE IN ACCORDANCE WITH AWPA M4. <br /> 3. CONTRACTOR SHALL USE MANUFACTURER'S RECOMMENDED SCREWS AND NAILS FOR ALL 0 6 12 <br /> CONNECTORS UNLESS NOTED OTHERWISE. <br /> SCALE IN INCHES <br /> 6 �II "" PROJECT ENGINEER: SCALE: ^ DWG. N0. <br /> � COAST SZ HARBOR A. PORT rORT 4F EVERETT <br /> � ENGINEERING ER AS NOTED � O <br /> O� A Division of Hatch Mott MacDonald �E P�LI <br /> v 110 JAMES ST, STE 101 EDMONDS, WA 98020 �� WAS `as DESIGNED BY: DATE: <br /> PH 425-778-2542 • FAX 425-778-6883 hw�� ,. � ��' A. P 0 R TE R 6/2 7/16 S O U T H T E R M I N A L B U L K H EA D C I P N 0. <br /> �� � RENOVATION SITE A <br /> VERETT DRAWN BY: CHECKED BY: ( 1 1 -0-031 -02 <br /> �, T. MORRISON S. PHILLIPS � � PROJECT N0. <br /> . <br /> P.O. BOX 538 �, 34b56 ,9 <br /> EVERETT, WA982o6 ����5�����" APPROVED BY: WALKWAY QETAIL MT-ST-2016-04 <br /> (425)259-3164 N0. DATE BY REVISION N0. DATE BY REVISION oN'�' JOHN K. � � SHEET N0. <br /> - 10 OF 10 <br />