Laserfiche WebLink
99,-5„ <br /> 5 � � PROPOSED WALKWAY EXI STING TIMBER PILES (BELOW) <br /> 9 � � �-- 4'-0" ON CENTER, TYP. <br /> EXISTING TIMBER LAGGING (BELOW) <br /> , <br /> ���� � , �: , �. . , ,� � � � � � � <br /> a r a � a � a r � d a � n a � � y ti o a � e 6 a o n n c � � n n . n � tl o � c x <br /> EXISTING DRAIN PIPE DECKING <br /> 2'-0", MAX. <br /> EXISTING BUI�DING � � <br /> CONCRETE ANCHOR 6" EA SIDE OF LEDGER JOINT, TYP. <br /> 4 EXISTING BUILDING <br /> 3 PLAN VIEW ANCHOR BOLT, TYP. - <br /> FOOTPRINT <br /> - NEW WALKWAY <br /> GALVANIZED STEEL CONNECTION AT <br /> 0 4 8 <br /> GUARDRAIL JOINT, TYP <br /> 3'-0" 2'-0" SCALE IN FEET 2'-11 " 2'-11 " <br /> GUARDRAIL PIPE EXTENSION SEE B RIM JOIST 8 <br /> 1 .9 g g � 9 10 GUARDRAIL POST, TYP <br /> -' GALV. STEEL ANGLE <br /> , , \ i' EXISTING TIMBER WALER <br /> ,; <br /> �� EXISTWG TIMBER LEDGER <br /> , � <br /> � , „ <br /> , <br /> �. � , ,, <br /> � „ � � <br /> , i _ _ <br /> �, <br /> � <br /> :_ l ... <br /> --- - ----- � <br /> - ---- ------ <br /> ----- -_ -- ---- <br /> ------ <br /> --- ----- <br /> ----- - -------- J 01 S TS TO B E <br /> � -- ----_____ <br /> ------- ----- � ________ <br /> GALV. STEEL PLATE 1 /4"X8" CONNECTED WITH <br /> W/(2) 5/8"� STEEL BOLTS GALVANIZED STEEL STRINGER <br /> � ANGLE, SIMPSON <br /> �, THROUGH EACH RIM JOIST STRONG THE ML26Z <br /> ,, OR EQUAL ALL FOUR JOIST � <br /> � �, CORNERS, TYP � <br /> � N <br /> O <br /> I <br /> � , �; :: � g / � <br /> GUARDRAIL � <br /> 9 10 EXISTING TIMBER LAGGING <br /> � � 1 <br /> , � �� <br /> , � � --�� -- -----_- <br /> ,,- --- ------- � <br /> � _--;�- -__ <br /> , <br /> ., �; <br /> _-- <br /> SHIM W/ �' 4X4 TREATED\ � � <br /> GALV. FRAMING ANGLE SIMPSON LEDGER TREATED TIMBER TIMBER POST <br /> T <br /> � <br /> STRONG IE LS90Z OR E UAL <br /> Q <br /> _ �,; <br /> � � SHIM W/ <br /> � � I I�j ��' TREATED TIMBER <br /> � <br /> „ �� <br /> (2) 5�8 4� GALV. STEEL � �! � ���� <br /> � , ._, < <: <br /> THROUGN-BOLTS AND `S' \ .__. ' ._, . GALV. FRAMING ANGLE SIMPSON <br /> WASHERS BETWEEN STRINGER ' 1 '-2" -�I EXISTING DRAIN PIPE STRONG TIE LS90Z OR EQUAL <br /> AND 4X4 POST, TYP. ' � O G�R. <br /> � � <br /> � ,' � <br /> � ��L <br /> , <br /> , � <br /> � <br /> _____ � <br /> ��, � <br /> 9 <br /> 9 10 <br /> S ,, EXISTING BUILDING <br /> 4X4 TREATED TIMBER POST ��' , �° <br /> rL <br /> , , <br /> , i�' <br /> DECKING NOT SHOWN � 4 DETAIL <br /> FOR C�ARITY - WALKWAY END GENERAL NOTES <br /> 0 1 2 1 . AT JOIST SP�ICES PROVIDE (2) GAL�ANIZED TIE <br /> 3 DETAIL PLATES SIMPSON STRONG TIE TP47 OR EQUAL. <br /> SCALE IN FEET 2. NO SPICES ARE ALLOWED FOR STRINGERS. <br /> _ WALKWAY END 3. CONTRACTOR SHALL USE MANUFACTURER'S <br /> RECOMMENDED SCREWS AND NAILS FOR ALL <br /> 0 1 2 CONNECTORS UNLESS NOTED OTHERWISE. <br /> SCALE IN FEET <br /> � COAST $Z HARBOR �I��' PROJECT ENGINEER: SCALE: PORT OF EVERETT DWG. N0. <br /> � ENGINEERING �� �L A. PORTER AS NOTED � <br /> �� A Division of Hatch Mott MacDonald �' P I1°s DESIGNED BY: DATE: <br /> Or O � 110 JAMES ST_STE 101 EDMONDS, WA 98020 � �4WASNl� A. PORTER 6 27 16 SOUTH TERMINAL BULKHEAD <br /> PH 425 778 2542 • FAX 425 778 6883 �4i � � C I P N 0. <br /> ` RENOVATION SITE A <br /> VERETT DRAWN BY: CHECKED BY: 1 -0-031 -02 <br /> T. MORRISON S. PHILLIPS � PROJECT N0. <br /> P.O. BOX 538 q �i <br /> 3+#�i56 <br /> EVERETT, WA98206 � °�'����'IS'I'��'G�;�" APPROVED BY: MT-ST-2016-04 <br /> (425)259-3164 N0. DATE BY REVISI N N . ����"�`� �OHN K. WALKWAY DETAILS 1 SHEET N0. <br /> 0 0 DATE BY REVISION <br /> 9 OF 10 <br />