BUILDING CODE <br /> 2012 INTERNATIONAL BUILDING CODE : GENERAL A , t <br /> 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO <br /> FLOOR LOAD THE CONTRACT DRAWINGS. II I I m� h <br /> DEAD LOAD : 12 psf y 4 <br /> LIVE LOAD: 40 Psi 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR � c f N 8 <br /> ROOF LOAD- SHALL BE RESPONSIBLE FOR THE SAFETY Of THE BUILDING. <br /> THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, (-D- 0 <br /> DEAD LOAD:15 psf BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, �� �-;� <br /> FLAT ROOF SNOW LOAD: 25 psf STATE AND:LOCAL SAFETY ORDINANCES. ANY DEVIATION --�J <br /> SNOW EXPOSURE FACTOR(Ce): 1.1 MUST BE APPROVED PRIOR TO ERECTION. <br /> B 4.) <br /> SNOW LOAD IMPORTANCE FACTOR(Is): 1.00 <br /> THERMAL FACTOR(Ct):1.1 3.:ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA " <br /> STANDARDS. ANY DEVIATION MUST BE APPROVED BY OSHA .O c <br /> WIND DESIGN DATA PRIOR To ERECTION. O <br /> 1.BASIC WIND SPEED:-:110..MPH <br /> 2.WIND IMPORTANCE FACTOR(Iw): 1.0 4.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL . Q ^v <br /> BUILDING CATEGORY: II CONSTRUCTION PROCEDURES INCLUDING LAGGING, Q ne 3? o <br /> 3:WIND EXPOSURE: B SHORING AND PROTECTION OF ADJACENT PROPERTY, - C N d <br /> 4.Kzt= 1 INTERNAL PRESSURE COEFFICIENT: NA STRUCTURES,STREETS AND UTILITIES IN ACCORDANCE WITH C © _ no W a - <br /> 6.APPLICABLE WIND PRESSURE FOR ALL NATIONAL,STATE AND LOCAL SAFETY ORDINANCES. �. 0 L t/1 V Q a <br /> COMPONENTS AND CLADDING: NA Q 1:1) <br /> O 3 0 <br /> 1 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR E _ c 2 M <br /> COORDINATING THE WORK OF ALL TRADES AND SHALL m <br /> SESIMIC DESIGN DATA 1, p N ,� <br /> T.SEISMIC IMPORTANCE FACTOR: 1.0 CHECK ALL DIMENSIONS.ALL DISCREPANCIES SHALL BE 1 .It •:•::.,p , , -. fi L. . <br /> SEISMIC USE GROUP: I CALLED TO THE ATTENTION OF THE ENGINEER AND BE _ :` IL'_ lL -, IL:, .}t� W <br /> o RESOLVED BEFORE PROCEEDING WITH THE WORK. • _ ': .f•-.': : . " D Z <br /> 2.SPECTRAL RESPONSE ACCELERATION(Ss). 120.9/o G • : <br /> 3.SITE CLASS:D(ASSUMED) :l. :.'<. .., ;.._ i <br /> 82.0%G6.SHOP DRAWINGS FOR PREFABRICATED TRUSSES AND `' '� <br /> 4.SPECTRAL RESPONSE COEFFICIENTS(SDS). 'i ;', •• , • � �: '' � 4 `' ''` (j � <br /> MANUFACTURED FLOOR JOISTS SHALL BE SUBMITTED TO THE '•. ' • •" . <br /> S.SEISMIC DESIGN CATEGORY: D �� '" " ` "`� " •� '� -� '' "' ` ��` <br /> 6.BASIC SEISMIC-FORCE-RESISTING SYSTEM:SHEARWALLS ENGINEER FOR REVIEW PRIOR TO FABRICATION. <br /> 7. DESIGN BASE SHEAR:SEE CALCULATIONS DOUBLE TOP PLATE W/EDGE NAILING(STAGGER) `: G HOLDOWN PER SCHEDULE AND PLAN <br /> 8.SEISMIC RESPONSE COEFFICIENT(Cs):.088 7. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF ® <br /> 9. RESPONSE MODIFICATION FACTOR(R): 6.5 CONSTRUCTION. WHERE CONDITIONS ARE NOT (HDQ8-SDS3 SHOWN) <br /> 10.ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE SPECIFICALLY.INDICATED BUT ARE OF SIMILAR CHARACTER TO ©SHEARWALL EDGE NAILING AT ALL.PANEL EDGES. H COORDINATE ALL STUD AND PLATE SIZES <br /> DETAILS SHOWN,SIMILAR DETAILS OF CONSTRUCTION SHALL BLOCKING AT ALL PANEL EDGES WHERE APPLICABLE. 0 w/SHEARWALL SCHEDULE REQUIREMENTS <br /> FRAMING LUMBER: BE USED SUBJECT TO REVIEW BY THE ENGINEER. <br /> 1. FRAMING LUMBER SHALL BE HEM-FIR NO. 2: GRADES ARE.TYPICAL UNLESS OTHERWISE ©.EDGE NAILING TO HOLDOWN POST(FULL HEIGHT) <br /> 8.ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL STAGGER INTO DOUBLE STUDS J EDGE NAILING TO POSTS,TRIM STUDS, <br /> NOTED ON PLANS. LUMBER TO BE GRADE MARKED PER WCLIB SPECIFICATIONS. O EDL M <br /> OCCUR IN ADDITION TO ANY OTHER SPECIFIC D_ETAIL CALLED QD STUDS @ 16"ON CENTER AND KING STUDS <br /> 2.STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD OR OSB,EXPOSURE 1 SHEATHING: OUT. Q PRESSURE TREATED SILL PLATE WITH EDGE NAILING O BEARING STUD FOR HEADER LJ.J E0-1 O <br /> CONFORMING TO EITHER COMMERCIAL STANDARDS P51-83,APA PRP-108,OR VOLUNTARY AND ANCHOR BOLTS PER SHEARWALL SCHEDULE. Q 00 <br /> 9 COORDINATE WITH MECHANICAL,PLUMBING,AND <br /> PRODUCT STANDARD PSE-92. PROVIDE A MINIMUM'OF 3/e"EDGE DISTANCE ON.ALL NAILS AND ©RIMJOIST TO BE 132"MIN THICKNESS AT W <br /> ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF ALL TOP PLATE SPLICE NAILING`TO BE(8) 1 <br /> Y".EXPANSION JOINT BETWEEN ALL PANEL EDGES.MINIMUM SHEATHING REQUIREMENTS ARE 0 bd SINKERS(MIN). ALL SHEARWALLS 0 H <br /> AS FOLLOWS: OPENINGS REQUIRED FOR DUCTS,PIPES,PIPE SLEEVES, LAP 48"MINIMUM.`CENTER SPLICE ON STUD. d J Q <br /> ELECTRICAL CONDUITS,AND OTHER ITEMS TO BE EMBEDDED <br /> ROOF SHEATHING TO BE 15/32"INT-APA RATED PLYWOOD OR 46 OSB WITH EXTERIOR INONCRETE OR OTHERWISE INCORPORATED IN STRUCTURAL <br /> GLUE,P.I.24/0. NAIL WITH' 10d NAILS AT 6"ON CENTER AT PANEL EDGES AND 12" W '� <br /> ON CENTER AT INTERMEDIATE MEMBERS: WORK STD.. SHEARWALL ELEVATION W/ RIM <br /> 10.PROVIDE OPENINGS AND SUPPORTS,AS REQUIRED PER SCALE: "=1'-0' Z, <br /> Yto <br /> SUB FLOORING TO BE%4"TONGUE AND GROOVE C-D INT-APA RATED PLYWOOD OR STANDARD DETAILS FOR HEATERS,MECHANICAL EQUIPMENT, <br /> OSB WITH EXTERIOR GLUE,P.1.48/24. GLUE AND NAIL WITH 10d NAILS AT 6"ON �. W <br /> VENTS,DUCTS,PIPING,ETC:'ALL SUSPENDED:MECHANICAL <br /> CENTER AT PANEL EDGES AND 12"ON CENTER AT INTERMEDIATE MEMBERS. O <br /> EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. <br /> O <br /> LJJ <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE <br /> UNLESS NOTED OTHERWISE.: USE COMMON NAILS THROUGHOUT UNLESS NOTED 11.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE CN <br /> OTHERWISE. TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT <br /> KNOWLEDGE BUT WITHOUT GUARANTEE OF.ACCURACY. <br /> UNLESSSPECIFICALLY DETAILED OR WHERE ACTUAL CONDITIONS CONFLICT WITH THE <br /> 4.NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED DRAWINGS;THEY SHALL BE REPORTED TO THE ENGINEER SO TRUSS PER PLAN <br /> APPROVED IN WRITING BY THE STRUCTURAL ENGINEER THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION I / - OLr. <br /> 8d,@ 6"'"0/C INTO BLOCKING k " <br /> 5:PROVIDE PROPERLY SIZED WASHER UNDER HEADS AND NUTS OF ALL BOLTS AND LAG TO DETAILS OF CONSTRUCTION SHALL NOT BE MADE g ,0,..-..4,4 -'-'1"-..< O <br /> S U WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. H1 CLIP @ EACH TRUSS ` 7 . '` o <br /> SCREWS BEARING ON WOOD, / ; , <br /> (24"0/C MAX) <br /> 12.ARCHITECTURAL AND MECHANICAL PLANS ARE <br /> 6.PROVIDE 3"x3"x0.229"WASHERS AT ALL' ANCHOR BOLTS. it <br /> CONSIDERED_A PART OF THE STRUCTURAL DESIGN DRAWINGS );_ m -.,:&-0 ce <br /> AND ARE TO BE USED TO DEFINE DETAIL CONFIGURATIONS :)NAL, <br /> 7. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS Xs UNLESS NOTED OTHERWISE. c �' <br /> LAG BOLT PILOT HOLES SHALL BE PRE-DRILLED TO 60%OF THE NOMINAL DIAMETER OF THE INCLUDING;BUT NOT LIMITED TO RELATIVE LOCATION OF VENTILATION MAY BE REQ'D <br /> LAG BOLT UNLESS NOTED OTHERWISE, MEMBERS,ELEVATIONS, DIMENSIONS AND LOCATIONS OF ALL AT BLOCKING.VERIFY M`AY L .5 2016 <br /> OPENINGS, ETC. WALL PER PLAN-NAIL "F" <br /> METHOD W/ENGINEER:PRIOR I ATF.RALONLY <br /> 5 SHEATHING INTO EA TO CONSTRUCTION. BIRD <br /> 0 <br /> 8.ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH �8 MINIMUM DIAMETER MEMBER OF TOP PLATE B Drawn B :FF <br /> BOLTS SPACED AT A MAXIMUM OF 48"ON CENTER. BOLTS MUST BE EMBEDDED A MINIMUM LOCKING IS ACCEPTABLE: Y <br /> OF`7"INTO CONCRETE.OR MASONRY. SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS C ate:0_-3 CCC <br /> Date:07-31-15 <br /> "WHERE APPLICABLE. ROOF/SHEARWALL CONN, <br /> SDA JOB NO. <br /> 9. RIM JOIST IS TO BE 1)4 LSL MINIMUM. 7592 <br /> - 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION WALLS AND SOLID BLOCKING STRUCTURAL "-.• <br /> UNDER PERPENDICULAR PARTITION WALLS. NOTES '' <br /> ' <br /> 11.CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS. S- 1 0 :' <br />