My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2409 W MUKILTEO BLVD 2018-06-07
>
Address Records
>
W MUKILTEO BLVD
>
2409
>
2409 W MUKILTEO BLVD 2018-06-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2018 4:02:47 PM
Creation date
6/7/2018 4:02:43 PM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
2409
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EPDXY HOEDOWN SCHEDULE.: _� <br /> SHEARWALL SCHEDULE (CDX) <br /> 'FOR EPDXY INSTALLATIONS INTO EXISTING CONCRETE ,a <br /> ANCHOR EMBEDMENT MIN. EDGE SILL PLATE&CONN.@ BOTFOM/TOP PLATE Q4 <br /> MARK SHEATHING EDGE NAILING FIELD NAILING I N 6 <br /> MODEL FASTENERS TO POST FND CONN. <br /> BOLT LENGTH DISTANCE <br /> HDU2-SDS2.5' 0 ATR (6)Y4"x'24"SDS SCREWS 7 4" : 1/4" 1 /8"CDXONE FACE8d 6"O C 8d 12"O C �"O A.B.@ 48"O/C W/ LTP4`@ 20"0/C W/2x <br /> a @ L @. / 2x SILL PLATE BOTTOM PLATE <br /> HDU4-SDS2.5 i"0 ATR (1 0)Y"X 2 4"SDS SCREWS 74" 13/4" A 5 " w " <br /> 2\' %"CDX ONE FACE 8d @:4"0/C 8d @ 12"0/C /8 0 A.B.@ 36 O/C W/ LTP4 @ 14 0/C W/2x <br /> / <br /> N <br /> 2x SILL PLATE BOTTOM PLATE <br /> HDU8-SDS2.5 i"0 AIR (20)Y"x 2 4"SDS SCREWS 13i" 134. ..;;77. <br /> SHEARWALL NOTES O _i <br /> --. - HOLDOWN NOTES _°" '4''.` _. 1.ALL STUDS, BLOCKING,'TOP AND BOTTOM:PLATES SHALL BE HEM-FIR-NO.2 UNLESS NOTED OTHERWISE ON PLANS: ALL N '? ^ v <br /> 1.ALL-THREAD BOLTS SHALL CONFORM TO ASTM A307. SHEATHING EDGES MUST BE BACKED WITH 2x OR WIDER FRAMING(SEE NOTE#3). Q' W "7 "`a <br /> C <br /> 2.MINIMUM CONCRETE COMPRESSIVE STRENGTH fc= 2500 PSI. MINIMUM WALL THICKNESS IS 8". 2.:SHEATHING MAYBE INSTALLED:EITHER HORIZONTALLY OR VERTICALLY. .ALL SHEARWALL SHEATHING MUST EXTEND TO �_ "- -� <br /> THE OUTISDE_EDGE OF ALL HOLDOWN POSTS AND CORNERS,AND TO.THE INSIDE EDGE OF FRAMING AROUND' �. 6 <br /> a 2 <br /> 3.ALL HOLDOWNS REQUIRE A(2)2x POST UNLESS NOTED OTHERWISE. WHERE HOLDOWNS ARE OPENINGS: (23 0., <br /> INSTALLED INTO THE WIDE FACE OF THE STUD,STUDS MUST BE STITCH NAILED-TOG_ ETHER w/16d SINKERS <br /> STAGGERED @ 4"o/c. 3. WHERE SHEATHING NAILING IS SHEARWALL.#3 AND GREATER, ALL' FRAMING MEMBERS RECEIVING EDGE NAILING FROM --:8 d <br /> ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3-INCH'NOMINAL MEMBER. ADDITIONALLY,WHERE SHEARWALLS L r LU ,cg <br /> 4.MINIMUM EDGE DISTANCE IS FOR FORMED CONCRETE EXPOSED TO WEATHER OR SOIL. FOR CONCRETE ARE SHEATHED ON BOTH FACES,ALL STUDS AND PLATES RECEIVING EDGE NAILING FROM BOTH FACES MUST BE A SINGLE } i;; <br /> CAST AGAINST SOIL PROVIDE 3"CLEAR TO ANCHOR BOLT. 3-INCH NOMINAL MEMBER OR PANEL JOINTS MUST BE STAGGERED. IN EACH OF THESE CASES 3x STUDS ARE REQUIRED U Z <br /> UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLANS BY THE ENGINEER. FOR SHEARWALLS#3 AND#4,A 2x SILL PLATE L O <br /> MAY BE USED IF TWO TIMES THE NUMBER.OF ANCHOR BOLTS REQUIRED BY THE SHEARWALL SCHEDULE ARE USED AND ARE <br /> 5. NAILS/SCREWS TO HOLDOWN POST SHALL BE PER MANUFACTURER'S SPECIFICATIONS. c-.1/.5' °- <br /> EVENLY SPACED(SEE 2003 IBC SECTION 2305.3.10)- <br /> 6.WHEN FIELD CONDITION BECOME LESS THAN MINIMUM SHOWN,CONTACT ENGINEER PRIOR TO <br /> PROCEEDING. 4. SHEARWALL NAILING CRITERIA IS BASED ON TABLE 2306.4.1 OF THE INTERNATIONAL BUILDING CODE(fOR CDX)OR <br /> REPORT NER-124(FOR OSB): VALUES ARE BASED ON HEM-FIR NO.2 FRAMING WITH COMMON NAILS. <br /> 7.ALL HOLDOWN BOLTS MUST BE RE-TIGHTENED JUST PRIOR TO ENCLOSING SECOND SIDE OF WALL. <br /> 5.HOEDOWNS AND OTHER CONNECTIONS MAY BE REQUIRED AT THE ENDS OF MANY SHEARWALLS. SIZES AND <br /> 8.HOLDOWNS MAY BE ATTACHED TO EXISTING CONCRETE USING SIMPSON'SET-XP HIGH STRENGTH LOCATIONS OF THESE CONNECTORS ARE INDICATED ON THE PLANS. REFER TO THE APPROPRIATE DETAILS AND/OR <br /> EPDXY. SIZE AND EMBED`PER CHART. ICBG REPORT NO. ER-5279. DRILL ANCHOR BOLT HOLES '/a"LARGER HOLDOWN SCHEDULE FOR ADDITIONAL INFORMATION REGARDING ANCHOR BOLTS, EMBEDMENT LENGTH,ETC. WHERE <br /> THAN ANCHOR BOLT.DIAMETER. (2)2x's ARE USED AS A HOLDOWN POST,SHEARWALL EDGE NAILING MUST BE STAGGERED INTO EACH MEMBER OF.THE Q <br /> POST. <br /> ce) <br /> 6.ANC1-10RCOLTS MUST BE EMBEDDED A MINIMUM OF 7"INTO CONCRETE OR GROUTED CMU,AND SHALL BE PLACED TO cNi <br /> W m . <br /> PROVIDE A MINIMUM OF 2"' COVER. PROVIDE 3°COVER FOR CONCRETE CAST AGAINST SOIL <br /> 0 00 <br /> HOLDOWN SCHEDULE 7.ALL MACHINE BOLTS SHALL BE ASTM A307 OR BETTER. HILTI KWIK BOLTS/SIMPSON TITEN`HO BOLTS OF THE SAME 0 w <br /> DIAMETER AS SHOWN IN THE SHEARWALL SCHEDULE MAY BE SUBSTITUTED FOR ANCHOR BOLTS INTO EXISTING CONCRETE: C I Q <br /> *FOR HOLDOWNS INSTALLED IN NEW FOUNDATIONS BOLTS SHALL BE EMBEDDED A MINIMUM OF 5'INTO EXISTING CONCRETE. <br /> ANCHOR THRU'BOLTS OR EMBEDMENT/ MINIMUM <br /> MODEL BOLT NAILS/SCREWS : STRAP LENGTH EDGE DIST. le de <br /> 8.ALL NAILS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD EXCEPT FOR BC ORITE TREATED WOOD) (j) <br /> MUST BE HOT DIPPED GALVANIZED OR STAINLESS STEEL TO RESIST CORROSION. . j <br /> CS14 N/A (30)-10d COMMON IN 34"+ CLEAR SPAN CENTER ON NA NA LJJ <br /> SINGLE STUD RIM JOIST <br /> 9.WHERE 10d NAILS ARE SPACED AT 3"ON CENTER OR LESS,NAILS MUST BE STAGGERED. <br /> i <br /> -N <br /> 0% > <br /> 10.OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR CDX SPECIFIED IN SHEARWALL SCHEDULE. Q`W <br /> HOLDOWN NOTES �h <br /> CV <br /> 1.ALL-THREAD BOLTS SHALL CONFORM TO ASTM A307. <br /> 2.MINIMUM CONCRETE COMPRESSIVE STRENGTH fc:= 2500 PSI. MINIMUM WALL THICKNESS IS 8". <br /> 3..ALL HOLDOWNS REQUIRE A(2)2x POST UNLESS NOTED OTHERWISE: WHERE HOLDOWNS ARE INSTALLED INTO THE . , , <br /> WIDE FACE OF THE STUD STUDS MUST BE STITCH NAILED TOGETHER w/16d SINKERS STAGGERED 4"o/c. HOLDOWN POST. SEES' . <br /> @ HOEDOWN SCHEDULE OR PLAN <br /> FOR DOUBLE SIDED SHEARWALLS,THE ,:r ,„,i-s'. A,_ o <br /> SHEATHING ON EACH FACE MUST EXTEND /1 w t ; J/,._, : <br /> 4.MINIMUM EDGE DISTANCE IS FOR FORMED CONCRETE EXPOSED TO WEATHER OR SOIL. FOR CONCRETE CAST : FOR MINIMUM REQUIREMENTS y 5 <br /> AGAINST SOIL PROVIDE 3"CLEAR TO ANCHOR BOLT: <br /> CONTINUOUS BETWEEN HOLDOWN POSTS AS , ''',-"P',. <br /> rh <br /> LENGTH OF SHOWN.:. 14sa <br /> 5.NAILS/SCREWS TO HOEDOWN POST SHALL BE PER MANUFACTURERS SPECIFICATIONS. SHEARWALL : <br /> 6.WHEN FIELD CONDITION BECOME LESS THAN MINIMUM SHOWN,CONTACT ENGINEER PRIOR TO PROCEEDING_ _ Y 5''2D16 1 <br /> ��11� I I LATERAL ONLY <br /> 7.ALL HOLDOWN BOLTS MUST BE RE-TIGHTENED JUST PRIOR TO ENCLOSING SECOND SIDE OF WALL. '.V.( )��I HI� <br /> IIIIIIM OPENING PER PLAN <br /> LOCATION OF HOEDOWN <br /> Drawn Br FF <br /> TO BE INSTALLED STHD14RJ CDate•07-31ecked By: C <br /> C 5C <br /> TYPE OF HOLDOWN TO BE INSTALLED SDA JOB NO. <br /> 7592 <br /> SHEARWALL DESIGNATION-SEE SHEARWALL . <br /> SCHEDULE FOR FRAMING,NAILING AND STRUCTURAL <br /> ANCHORAGE REQUIREMENTS <br /> NOTES/DETAILS .r <br /> LATERAL MARKING LEGEND O 7 <br /> 2 <br /> iF 1.: : :1.4<Jlo <br />
The URL can be used to link to this page
Your browser does not support the video tag.