My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2108 RUCKER AVE 2018-06-08
>
Address Records
>
RUCKER AVE
>
2108
>
2108 RUCKER AVE 2018-06-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2018 9:10:59 AM
Creation date
6/8/2018 9:10:40 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2108
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14. The new sewer main in the alley shall be constructed and connected to the City sewer on <br /> 21st street The side sewers shall be connected to the new 8-inch sewer main in the alley. A <br /> backwater valve must be installed on all new sewer main connections. <br /> 15. Walkways must be provided from the building entrance to the public sidewalk.. <br /> 16. The construction plans must be designed from a site survey performed by a licensed State of <br /> Washington land surveyor. <br /> 17. All exposed ground must be reseeded within 30 days of the completion of construction. If <br /> reseeding is not practical due to weather or seasonal problems, the ground must be covered <br /> with mulch as directed by the City Engineer. <br /> 18. Temporary erosion control measures for construction activity must be operational prior to • <br /> commencement of any clearing or earthwork. <br /> Steve Goforth-Fire Department Comments—425.257.8100 <br /> 1. Access -O.K. as shown on the site plan reviewed. <br /> 2. A Knox Box is required.2015 IFC 506.1 For sprinkler room/alarm access. Order Box#3270 <br /> by visiting www.everettfire.org <br /> 3. Knox fire department connection_ caps are required for all OUTSIDE FDC and standpipe <br /> connection points with lockable caps,visit www.everettfire.org for order information. <br /> 4. Fire Alarm System-An approved automatic fire detection system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval <br /> prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests,witnessed by a Fire Department Inspector, shall be performed, along <br /> with a certificate of completion,prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72,2013 Edition. <br /> Installation of fire alarm components,including basic wiring,may not commence <br /> before plans are approved by the Fire Department Plan Reviewer. Fire alarm drawings <br /> must be professionally rendered,in sufficient detail,and must be internally consistent. Riser <br /> diagrams must match installation plans and load calculations. Components must be listed <br /> and approved for use together. Changes to plans must include new drawings and calculations <br /> and must be approved by the Fire Department Plan Reviewer prior to installation. Fire alarm <br /> installation is subject to field inspection by a Fire Department Inspector. An approved set of <br /> plans and the Engineering&Public Services.Department electrical permit must be present <br /> for any installation inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering& <br /> Public Services Department. Electrical inspections and approval are required prior to calling <br /> for acceptance tests. Call (425)257-8810 for permit information. <br /> Planning Director Decision Pale 5 of 7 <br /> HC 16-001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.