Laserfiche WebLink
GENERAL NOTES <br /> TH(S ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE <br /> ELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL <br /> CONTRACTOR'S DESIGN SHALL BE APPROVED BY THE OWNER AND SHALL <br /> CONFORM TO THE APPLICABLE ELECTRIC CODE REGARDLESS QF WHATIS � <br /> SMOWN ON THIS DRAWING. � <br /> METER CENTER LOCATIONS SHALL BE C�ORDINATED WITH TNE ARCHITECT. �' <br /> HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTNER CONTROLS SHALL � � � � � � � �.. � ; <br /> MOUNTED NOT LESS THAN 36 INCHES ABOVE FLOOR. ELECTRICAL AND � ' <br /> COMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN, OF 15 �� � � � ��� � '����'� � �� '� <br /> INCHES ABOVE FLOOR. �''� �� � <br /> OUTLETS, SWITCHES, TELEPHONE AND TV, ETC. BOXES IN PARTY WALLS OF <br /> �► Cen#t��1 �1��, �u��e 21Q <br /> , ; <br /> ONE UNIT SHALL BE IN DIFFERENT STUD SPACES THAN THOSE IN ���i�C�t�n;t�i t�tl�t���+�fi��a'' �8C�3� ° � <br /> TNE ADJACENT UNIT. NO TWO ADJACENT UNlTS SHALL HAVE SUCH BOXES � ;��'����'�'�����:� �'����������, <br /> IN THE SAME STUD SPACE. BOXES SHALL BE SEPARATED HORIZONTALLY ` :�����i+�vV ��C�Xq�����'����t►�( '; <br /> BY 24". <br /> <.< ,: � <br /> 1NDIVIDUAL E�ECTRICAL OUTLET BOXES SHALL BE OF STEEL OR OTHER DRYER VENT <br /> APPROVED MATERIAL AND SHALL NOT BE GREATER THAN 16 SQUARE FROM ABOVE 5052 <br /> INCHES IN AREA. REGISTERED <br /> T � ARCHITECT <br /> THE WATER HEATERS SHAL.L BE STRAPPED PER IRC P2801.7 AT A POINT I � <br /> WITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF (TS VERTICAL DIMENSION. � _._ <br /> THE LOWER STRAP SHALL BE NOT LESS THAN 4" ABOVE ANY CONTRQLS. BATH � <br /> � ` i__ , I ROBERT E. WEIBLE <br /> WATER HEATERS SHALL BE PROVIDED WITH A PRESSUREfTEMPERATURE � �� � , � �,��� � , VENT j STATE OF WASHINGTON <br /> RELIEF VALVE THAT iS CONNECTED TO A DRAIN LINE. THE DRAIN L(NE TEL 1000W ELEC � � 1000W ELEC_________ \��1� � � TO PNOTOCELL <br /> SHALL BE DIRECTED TOWARD THE GROUND AND TERMCNATE AT A PdlNT NO CEILING HEATER I i '----�------- CEILING HEATER ----'---- -' .���--r i <br /> LESS TNAN 6" AND NO MORE THAN 24" ABQVE THE GROUND. � ( _ � _ _ , 1 ��` SMURF � WH � <br /> I , - ^ 11 � � i TUBE � � �' <br /> SMOKE DETECTORS SHALL BE EQUIPPED WITH A BATTERY BACK-UP SHALL � TV & OUTLET � I � � ' -� <br /> EMIT A SIGNAL WHEN BATTERIES ARE LOW, SHALL BE PERMANENTLY HARD I ( 72" OFF FLOOR � �� i FIREPLACE i I \�. i/ � <br /> WIRED AND WITHOUT A DISCONNECTING SWITCH OTMER TNAN THOSE � � Livin �. ; `� I � /' ` '^ <br /> REQUlRED FOR OVERCURRENT PROTECTION, AND SHALL SOUND AN ALARM CEILING � I g � � I ( <br /> g � � � <br /> AUdIBLE IN ALL SLEEPING AREAS OF THE DWELLING IN WHICH THEY ARE � FAN � , , � � ! TV , , � � / � <br /> � � � <br /> LOCATED. BedCOOCY�I 2 \� � j j � ( I ` %/ I <br /> I i \ � <br /> ENER�Y NOTES � �� +4 � � � , �,�, � ; , � � a <br /> SEE ENERGY NOTES ON SHEET A1 & D5. � STACK � _ _ � ' ' ` � PREWIRE LOW �` � , � <br /> THERMQSTAT � � - ; W.H. �AN ( � VQLTAGE WIRE � <br /> � j � 1 W/D I � VTR � � � I FOR GARAGE � CEILING � � <br /> WATER HEATER SHALL BE FUELED BY GAS AND HAVE A MWiMUM EF OF SD � � I � DOOR OPENER i � <br /> 0.82. T , , ! , , � & ELEC. EYES / � <br /> � � / ' s <br /> HOT AND COLD WATER HEATER PiPES IN UNCONDITIONED SPACES SHALL BE � ` I � � <br /> INSULATED WITH R-3 INSULATION WHICH HAS A FLAME SPREAD OF 25 OR � � � � � � \ � � � � � � / "¢ <br /> LESS. ; � � � � - I ----.-_-...-....--------.-.-.--------- I � <br /> � I i � � <br /> � <br /> � <br /> , � TR , , � � .. �.. � � � � �' % Garage , � <br /> � <br /> ' I Bat � , � ��___� ,�_�_�_----����_�� , ; f � <br /> VENTILATI4N NOTES I ! � m ,� � i I � ` , I , , ; <br /> � � ' � i M <br /> VENTILATION: SEE N�TES ON COVER SHEET. � ° ,�� � � ` � j � � N <br /> � U � � I / f � <br /> � <br /> i W � i i � / ,' M i i � y i � � � <br /> ALL EXHAUST DUCTS SHALL BE RiGID METAL, AND SHALL BE FITTED WITH A , � w � � ( " .,_. <br /> TIGHT FITTING BACKDRAFT DAMPER CAPABLE OF CLOSING WHEN THE FAN IS I ' � � � � � I � T <br /> NOT fN US�. � � � � Qinin � � ; � � � ,'� �. I ----_ � o <br /> � � Q <br /> DUCTS IN UNHEATED SPACES INCLUDING ATT(CS SHALL BE INSULATED TO A ' I . ' ' 1 � � i � �� � � Z � <br /> I <br /> MINIMUM OF R-8. I , ' \�\� PANEL � ---- , <br /> TOP FLOOR EXHAUST FANS SHALL VENT THRQUGH ATTIC. � � - -'" �. S� � w I �. � <br /> �. \ � 4'-4,� \ �w r � � _ w . <br /> �F vTR <br /> \ W= � � -a <br /> DRYER EXHAUST DUCT SHALL BE 4" RIGiD METAL WITH A 4" OPENING ON �\ � a � P °' �° <br /> THE EXHAUST HOQQ. THE DRYERS DUCTS SNALL BE GALVANIZED STEEL OR M. Bath � T� / ��`' �z � � I ___ ` � � <br /> „ � „ BELOW � ' �� ' ' � , � N <br /> ALUMINUM, MINIMUM 0.016 TNICK. THE DRYERS SHALL BE GENERAL � �+48 - � � I ( �? � <br /> ELECTRIC. DRYERS SHAL� BE INSTALLED ACCORDiNG TO MANUFACTURER'S �GFI +4$' \ �` � <br /> � � � j � o � <br /> �� INSTALLATION IN�STRUCTIONS ON SITE. � �F�� T��� ��� � � � � T ��� � � � �.�� �' ' <br /> i I T. I <br /> WINDOW OUTDOOR AIR INLETS SHALL PROVIDE THE EQU(VALENT OF 4 SQ. ' � � �-- --- --- ' ' � ` � � <br /> � ' ` { I <br /> IN. OF NET FREE AREA. I TEL � j i ' �+4 6" � I , / I � <br /> TOP � / � � �, � j � i � Z � <br /> � �HALF l � � � � �� I � j � � <br /> ' ` Master ,` � � � � ; W � � `I ; ; � Q J o N <br /> � � � � � �+46' � W Q � � I TEeH � , a Q � <br /> � � Bedroom � � I ` ' � � W= CHIME � i PORT , r o <br /> � i � � �� ENDAN oZ � � J <br /> � � �J � � a <br /> , i ,. , , R� � � �W � <br /> I i <br /> i / � CEILING FAN i � �F I , " NOOk � pen � � �Ilt.� � V <br /> � �� �. BOX � I M O � � Tv I ` �. � M .'' � j � � U <br /> . , � � I ; , � � 7500W ELEC � L m � <br /> �_ � <br /> � � � / TV I I � I Kitchen �..�.., _ ,..� CEILING HEATER \ � r 3 Q <br /> ELECTRICAL LEGEND , TOP f � � � �+46� � �� , , , � , I � � ' <br /> HALF 1000W ELEC i � W <br /> I � � � � <br /> CEILING HEATER i �-}- I � <br /> I � <br /> � DUPLEX RECEPTACLE �UTLET DIRECTIONAL CEILING � � 46" DW � � W <br /> MOUNTED LIGHT (�.��.�.. I I <br /> � DUPLEX RECEPTACLE OUTLET �----------- � <br /> -----� <br /> SPLlT WIRED (SWiTCH TQP NALF) � CEILING MOUNTED LIGHT � <br /> M� DUPLEX RECEPTACLE 011TLET � I <br /> MIGROWAVE � RECESSED CEILING LIGHT; "' - <br /> IC RATED - SEE 12/D1 <br /> � SINGLE RECEPTACL� OUTLET . � <br /> � <br /> 208v (R: RANGE, D: DRYER) -�- WALL MOUNTED LIGHT <br /> Q JUNCTION BOX <br /> �1�+ _ <br /> � � DOUBLE TUBE FLUORESCENT <br /> TECH PORT CEILING MOUNTED LIGHT � <br /> � <br /> TEL.� TELEPHONE JACK � CEILING MOUNTEQ TRACK LIGHT � <br /> � � <br /> T� TELEVISfON JACK F� �- HEAT LAMP, EXHAUST FAN . UPPER LEVEL . MIDDLE LEVEL . LOWER LEVEL � _ <br /> � SINGLE POLE SWITCH FIX�TU�RE TIo250W LAMP, 50� CFM Un�t E1A ELECTRICAL PLAN Un�t E1A ELECTRICAL PLAN UI"Ilt E1A ELECTRICAL PLAN � � <br /> �3 THREE WAY SWITCH MIN., 3 SONES, 4" ROUND DUCT. 1�4"=1'-0" 1�4"=1'-0" 1�4'Y=1'-0" � � <br /> SEE 15/D1 �' � <br /> DIM.� DIMMER SW[TCH ��a:�����.�� BEARING WALL - SEE NOTES � <br /> THIS SHEET REGARDING BOXES W � � U <br /> �r TIMER SWITCH AND FIRE-RATED WALLS ♦A � � .�,.r <br /> � RECESSED CEILING EXHAUST FAN � METER CENTER "♦ � t � <br /> 50 CFM MIN, 3 SONES MAX, N <br /> 4" ROUND DUCT. SEE 15/D1 o ELECTRICAL PANEL ELECTRICAL PLA�S FOR UNITS � � j � <br /> MICROWAVE OVEN/RANGE HOOD eo ELECTRIC BASEBOARD E1B E1C E1D 8�E1F IDENTICAL TO UNIT E1A � � <br /> � � L L <br /> (-�-� COMBfNATION, �OQ CFM, 3 SONES HEATER �.; <br /> V � � � <br /> SMOOTH DUCT. �T THERMOSTAT O ; Z <br /> � RECESSED HEAT LAMP - � SMOKE DETECTOR W <br /> "t" NUTONE 9410H, 250W LAMP WITH BATTERY BACKUP <br /> W = <br /> CEILING FIXTURE. SEE 12/D1 �F�► � <br /> � CARBON MQNOXIDE •�' � <br /> � PNOTOCELL SAFETY SENSOR ALARM/SMOKE DETECTOR � � <br /> � <br /> ❑ TECH PANEL � AUDIBLE SPR(NKLER � <br /> SFA F'LOW ALARM � 0' <br /> � RECESSED CEILING WHOLE WINDOW WITH OUTDOOR � <br /> �F HOUSE EXHAUST FAN �- AIR INLET <br /> 80 CFM MIN., 120 CFM MAX., <br /> 1.5 SONES, 6" ROUND DUCT � <br /> �PB PUSH BUTTON <br /> � .__„ <br /> VTR VENT TNROUGH ROOF <br /> � 1ob No.: 13-47 <br /> w <br /> z <br /> Sheet No.: <br /> � � �� <br /> Sheet Order: Q B U F R E S D I � <br /> _ <br />