• <br /> • <br /> • <br /> • <br /> GENERAL NOTES - PRESCRIBED INSULATION R-VALUES WINDOW AND DOOR SCHEDULE <br /> N CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING CAVITIES IMMEDIATELY ADJOINING EXTERIOR PORTIONS OF THE HOUSE SHALL BE INSULATED ACTUAL SIZE(INCHES) GLAZING • <br /> THE WORK. TO MEET THE FOLLOWING REQUIREMENTS UNLESS OTHERWISE NOTED IN THE PLANS. TAG TYPE* U-VALUE NOTES <br /> WORK SHALL COMPLY WITH THE FOLLOWING.CODES: EXISTING WALLS SHALL REMAIN IN CURRENT CONDITION UNLESS ALTERED. WIDTH(W) HEIGHT(H) SILL HEIGHT AREA(S.F.) - • k <br /> 2015 INTERNATIONAL RESIDENTIAL CODE EXTERIOR DOORS zz • <br /> 2015 WASHINGTON ENERGY CODE - ROOF R-49 BATT INSULATION <br /> OTHER CODES APPLICABLE BY JURISDICTION. ABOVE GRADE WALLS R-21 BATT INSULATION NEW a o <br /> FLOOR R-30 BAT INSULATION D1 SOLID- 42 80 NA NA 23.3 • .w <br /> AIR SEALING: w N <br /> ALL PLUMBING,ELECTRICAL,AND HVAC PENETRATIONS IN FLOOR,WALLS,AND CEILINGS NOTE: 2X4 EXTERIOR ABOVE GRADE WALLS MAX BE FULLY INSULATED WITH R 15 BATT D2 FRENCH 60 80 NA NA 33.3• ° N <br /> ARE CAULKED AND SEALED. • LNSULATION. EXISTING - • <br /> w <br /> 2. WHERE PENETRATIONS NEED A FIRESTOP;DISCWSS WITH BUILDING OFFICIAL. oo <br /> . 3. ELECTRICAL OUTLET AND LICHT SWITCH BOXES ON EXTERIOR WALLS MOST BE SEALED OTHER REQUIREMENTS: D3 SOLID 32 - 80 NA NA 17.8 <br /> AT THE BACK OF THE RECEPTACLE OR SEALED WITH FACEPLATE GASKETS. a. GUARDRAILS: MIN.36"HT.MAX.4"SPACING BETWEEN INTERMEDIATE MEMBERS(42" - D4 SOLID 108 84 NA NA 63.0 <br /> 4. SEAL RIM JOIST BETWEEN HEATED FLOORS OR USE PRODUCT LIKE"TYVEK"ON MIN.HT.FOR R-2 EXTERIOR). ¢ <br /> EXTERIOR. b. FLOORINGS: BOTIOV MIN.12'BELOW GRACE,TOP OF FCUNCATION WALL MIN.6"ABOVE D5 SOLID 108 84 NA NA 63.0 . <br /> -5. VAPOR BARRIER SHALL BE EITHER FACE STAPLED BATTS,4 MIL.VISQUEEN OR AN GRADE. • <br /> APPROVED VAPOR BARRIER PAINT. c. CONCRETE SLABS ON GRADE: 3-1/2"MI'-.THICKNESS. <br /> d. PIER BLOCKS: MIN 12"X 2 SIZE;RESTING ON CONCRETE PAD WIN.12"BELOW WINDOWS • <br /> aGRADE. NEW • <br /> EGRESS WINDOWS: REQUIRED FOR 1 'WINDOW/BEDROOM OR SLEEPING AREA(BELOW 4Th FLOOR) FOUNDATION WALLS: PROVIDE ONE(I)#4 REBAP TOP AND BOTTOM!AND AT ALL • <br /> AND1 WIN XH/BASEMENT. W1 FIX 60 • 80 Qi 0.30 33.3 SOT FLUSH W/ F.F <br /> VINDOWS/DOOR OPENINGS.LIMIT 4'MAX.BACKFILL. <br /> a MIN.NET CLEAR AREA=5.7 SO.FT (MIN.3'0"x 4'6"IF DOUBLE HUNG OR 4'0"x f. FOUNDATION ANCHOR BOLTS MIN.'./2"x 1O",6 F.ON CENTER MAX.WITH TWO(2) EXISTING _ YEN DESIGN INC <br /> 36"WINDOW IF SLIDER).5.0 SO.FT.IF SILL HEIGHT IS WITHIN 44"OF GRADE(ABOVE BOLTS PER PIECE OF PLATE AND AT LEAST ONE(1)BOLT WITH 12"AT END OF EACH <br /> OR BELOW). • PIECE(REQUIRE, FOR NEW CONSTRUCTION). W3 DH 32 46 34 0.30 1Q.2 WWW.YENDES.COM - <br /> a. MIN.NET CLEAR OPENING WIDTH=20"; MIN.NET CLEAR OPENING HEIGHT=24" ' g. ALL STRUCTURAL SOFTWOOD PLYWOOD,PARTICLE BOARD,WAFER BOARD,AND OSB W4 SH 70 46 34 0.30 22.4 EGRESS 1622 NE 179TH ST. <br /> MAX SILL HEIGHT=44" BOARD ARE STAMPED WITH EXPOSURE'1'OR'EXTERIOR'. W5 SH 46 58 - 22 0.30 18.5 EGRESS SHORELINE,WA,98155 ' <br /> REQUIRED GLAZING FOR HABITABLE ROOMS: A. WATER HEATER STORAGE TANK LABELED AS MEETING 1987 NAT'L APPLIANCE ENERGY <br /> CONSERVATION ACT..AORTAE STANDARD 0A-1980 INSULATION TO R-16 OR R-10 PAD - W6 SH 46 58 22 0.3Q 18.5 PHONE(206)432-1111 <br /> a. MIN.GLAZED EXTERIOR OPENING AREA=8%OF FLOOR AREA. IF LOCATED OVER.UNINSULATED SLAB <br /> b. GLAZED OPENINGS NOT REQUIRED WHERE PERMANENTLY INSTALLED ARTIFICIAL LIGHT ISI. INSULATE HOT AND COLD LATER PIPES TO R-3 IN UNHEATED AREAS MOO 84 58 22 0.30 33.8. EGRESS - APPROVAL STAMP <br /> PROVIDED. SHOWFJY.REGULATOR TO LIMIT HOT WATER DISCHARGE TO 2.5 GPM - W8 SH 46 58 22 0.30 18.5 <br /> C. OK IF OPENINGS ARE BELOW DECK&ROOFED PORCHES w/MIN.CEIUNG HEIGHT OF 7 k. WOOD STOVES AND FIREPLACES HAVE TIGHT FITTING DOORS,OUTSIDE COMBUSTION AIR <br /> FT.(LONG SIDE 65%OPEN). DUCTED TO FIREBOX WITH ACCESSIBLE DAMPER,MIN 6 SQ IN FREE VENT AREA.TIGHT . W9 OX 46 39 41 0.30 12.5 <br /> FITTING FLUE DAMPERS REVD. W10 OX 58 46 34 0.30 18.5 <br /> MECHANICAL/VENTILATION: REQUIRED FOR HABITABLE ROOMS OF ADDITIONS AND ALTERATIONS I. ALL GAS AND CIL COMBUSTION APPLIANCES HAVE A DIRECT VENT OR FORCED DRAFT <br /> MORE THAN 500 S0.FT OR THAT INCLUDE A KITCHEN,BATHROOM AND OTHER AREAS WHERE VENTING. - W11 SH . 46 46 '50 0.30 . 14.7 <br /> COOKING ODOR OR EXCESS WATER VAPOR WILL BE PRODUCED. m. RECESSED LIGHTS ARE I.C.RATED,DOUBLE WALL CAN LIGHTS OR WITHIN SEALED WPM W12 SH 48 46 34 0,30 15.3 <br /> a. MIN.50 CFM FOR BATHROOM AND LAUNDRY; MIN.ROD CFM FOR KITCHEN. BOX-IN. - <br /> b. MIN.AIR INTAKE OPENINGS=4 SQ.IN.PER ROOM. - Total 43,6 <br /> _. WHOLE HOUSE FAN MUST OPERATE AS SPECIFIED IN IRC IA1507.3 <br /> • <br /> SMOKE ALARMS: REQUIRED INSIDE AND OUTSIDE OF SLEEPING AREAS AND ON ALL FLOORS WINDOW&DOOR SCHEDULE NOTES <br /> DIRECT WIRING IS REQUIRED FOR SMOKE DETECTORS. _ 1. 00=SLIDER SH=-SINGLE HUNG,DH=DOUBLE HUNG,FIX=PICTURE,C=CASEMENT <br /> CARBON MONOXIDE ALARMS REQUIRED OUTSIDE SLEEPING AREAS AND ON ALL FLOORS, 2. -IF CONTRACTOR DECADES TO REPLACE WINDOWS,THEY MUST MEET ENERGY PERFORMANCE . <br /> UNLESS WORK ONLY INVOLVES EXTERIOR SURFACES OF THE BUILDING <br /> STANDARDS HEAT TREATMENT BE NERC <br /> REQUIREMENTS AND EGRESS REQUIREMENTS. <br /> 3. ALL WINDOWS'SHALL BE NFRC CERTIFIED. • <br /> - <br /> 4. CONTRACTOR TO VERIFY EGRESS AND HEAT TREATMENT REQUIREMENTS WITH WINDOW& <br /> STAIR REQUIREMENTS: (APPLIES TO ALL R-3 STAIRS AN R-2 PRIVATE STAIRWAYS): DOOR MANUFACTURER. <br /> a. MIN.WIDTH=36" ' 5. CONTRACTOR TO VERIFY WINDOW AND DOOR DIMENSIONS PRIOR TO ORDERING WINDOWS. <br /> b. MAX.HEIGHT/RISE=7-3/4 MIN.TREAD RUN=10° ' 6. EGRESS WINDOWS SIZED FOR"MILGARD STYLE LINE"SERIES WINDOWS.CONTRACTOR TO • <br /> c. MIN.HEADROOM=6'9" ' ' VERIFY EGRESS REQUIREMENTS IF A'DIFFERENT MANUFACTURER/MODEL IS CHOSEN. <br /> A. HANDRAIL 34"-38"ABOVE TREAD NOSING(RETURN ENDS) - <br /> - e. HANDRAIL GRASP DIMENSION: MIN.1-1/4",MAX.2" <br /> • <br /> IMNDING STAIRS: <br /> 1.MIN.TREAD RUN AT NARROWEST POINT=6" • <br /> 2.MIN.TREAD RUN 12"FROM NARROWEST POINT=10" W <br /> g. SPIRAL STAIRS: U <br /> 1.MIN.CLEAR WALKING AREA WIDTH=26" .. • ' - z <br /> 2.MIN.TREAD RUN 12"FROM NARROWEST POINT =7-1/2"/MAX. J W <br /> RISER HEIGHT=9-1/2" - <br /> • Lu Q <br /> 3.MIN.HEADROOM=6'6" 0 - <br /> INSULATION: _ • wo <br /> FACED BATTS ARE LAPPED AND FACE STAPLED AT FRAMING MEMBERS. LU N u1 W <br /> 2. ALL EXTERIOR WALL CAVITIES ARE FILLED WITH UNCOMPRESSED INSULATION,INCLUDING - N °P <br /> ALL CAVITIES ISOLATED DURING FRAMING,WIRING,AND PLUMBING. 1.= U j <br /> 3. ALL RECESSED FIXTJRES IN EXTERIOR WALLS HAVE RIGID BOARD INSULATION BEHIND • w 4 ¢ _ <br /> THEM. 2 Y Z F-w • <br /> 4. UNDER-FLOOR INSULATION IS SUPPORTED BY LATH,TWINE,OR OTHER CO + CD <br /> NON-COMPRESSING MEANS. ' - Q W w o w <br /> 5. ATTIC ACCESS IS BAFFLED,WEATHER-STRIPPED AND INSULATE. ' - y " 2 W <br /> • GARAGE-DWELLING FIRE SEPARATION 02$ W <br /> J • <br /> . A. 1-3/8"SOLID-CORE WOOD,1-3/8"SOLID OR HONEYCOMB STEEL OR 20 MIN.RATED • (n 0 <br /> GARAGE/DWELLING DOOR EQUIPPED WITH A SELF-CLOSING DEUCE. W <br /> B. MIN.1/2"GYPSUM WALLBOARD AT GARAGE WALLS AND 5/8"TYPE X GYPSUM BOARD ' - Ili I- W <br /> CEIUNG SEPARATING GARAGE FROM DWELLING IF APPLICABLE. z i <br /> C. WIN.1/2"GYPSUM WALLBOARD WRAPPING POSTS,BEAMS AND WALLS SUPPORTING THE ' z U <br /> DWELLING ABOVE THE GARAGE IF APPLICABLE. ' _J CO <br /> 126a <br /> W <br /> . Z 0 <br /> . W C <br /> • O o <br /> • <br /> 0 <br /> a <br /> . z_ <br /> . DRAWN BY F.L <br /> DESIGNER A.M.S. <br /> REVIEWER A.N.Y. <br /> JOB NO. 17-016 <br /> • SCALE SEE SHEET 0-: <br /> SHEET OF4 <br /> A1 .1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.