My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8908 9TH AVE SE 2018-06-08
>
Address Records
>
9TH AVE SE
>
8908
>
8908 9TH AVE SE 2018-06-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/8/2018 3:19:06 PM
Creation date
6/8/2018 3:19:03 PM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE SE
Street Number
8908
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ 66'-2 — / LEGEND <br /> / - 26'-10' :7-912` 6'-5' 5-9' t1.-5' _ ._ �. NEW STUD WALL <br /> / / <br /> rc <br /> i 18._3. 2-10' S'-9' 10` 5'-2g 6'-2y 4'_10' 9° 4-2' 1'-t0"5 - I•_I 5'-1U 4'-6° V///I EXISTING WALL TO REMAIN <br /> DEMOLISHED WALLS o <br /> / / •/ / /y )' y y / �' / / / / __. _...._ a o <br /> U <br /> ---- ROOF OUTLINE - o <br /> D3 `S SMOKE DETECTOR <br /> \ \ \ //////////////////////////I //////// - \ \ --.7~) INDICATES REFERENCE TO KEYNOTES SEE KEYNOTES ON THIS SHEET <br /> _\ / FOR BALANCE OF INFORMATION <br /> © CARBON MONOXIDE DETECTOR\ATH BATTERY BACKUP. <br /> EXHAUST FAN(INTERMITTENT) <br /> A$ SEE DOOR AND WINDOW SCHEDULE ON SHEET AT]FOR DETAILED INFO D <br /> • YEN DESIGN INC <br /> GENERAL NOTES WWW.YENDES.00M <br /> \ / GARAGE \ \ 1622 NE 179TH ST. <br /> <' //////// A. SEE SHEET Ali FOR COMMON CODE REQUIREMENTS. SHORELINE WA.96165 <br /> WV / - _� CARBON MONOXIDE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE PHONE(206)432-1111 <br /> ;WELLING AND PLACED IN PROXIMITY TO SLEEPING AREAS. <br /> / APPROVAL STAMP <br /> � <br /> / - \ - SMOKE DETECTORS SHALL BE INSTALLED ON ALL LEVELS OF THE DWEWNG AND <br /> / ' <br /> / , 12 WITHIN EACH SLEEPING AREA.DIRECT WIRING REQUIRE. <br /> 35 T EF, %' \ <br /> D. MANUFACTURER.WINDOW <br /> &DOOR ROUGH OPENING SIZES 77TH WON'&DOOR <br /> • 50CFM / <br /> / E. CONT ACTOR TO VFY ALL DIMENSIONS ON SITE PRIOR TO CONSTRUCTOR. <br /> r / <br /> \ - . F WH / / ��1►►aa "' F. CONTRACTOR TO DETERMINE&VERIFY ALL WASTE DIVERSION REQUIREMENTS <br /> / / / D2 I / 0 0 0 PER THE LOCAL JURISDICTION.CONTRACTOR MAY BE REQUIRED TO REQUEST <br /> \ '\ ® � —a \ \ •0��.!/////�►���%// %//_//�//.�5,�. / • \ \ LED REPORTS FROM RECEIVING FACILITIES. <br /> /////////f/ %/ �IIN�t•� <br /> / ELI..F.° / v AL.AC WITHOUT PLACEMENT DIMENSIONS WILL BE'"OFF WALL OR ON CENTER,4 <br /> N� `- J— ✓ �r.`r� - - % ( • % AS APPROPRIATE. <br /> At„ <br /> - <br /> o <br /> e , III �' 3C D • :711' .\( //' <br /> y <br /> t — 5 MASTER BED _/ <br /> / • t <br /> 0 i " . CD <br /> MASTS4. 61 ac —/ PLAN KEYNOTES <br /> / FAMILY ROOM / BATH U / 1. NON-BEARING WALLS TO BE REMOVED <br /> I- -1 I / <br /> /`-- i� I I i I 2. (N)BARN DOOR TO BE INSTALLED IN FRONT OF(E)R D <br /> / I -F 7 —� a— 4 C / <br /> -\ ^�___ I%_ ' • I 28 a- I" / BRICK CHIMNEY TO BE REMOVED,WALL TO BE ItiFILLEC WITH 2X W <br /> • EF - 8 : / STUDS TO MATCH(E)EX 20 <br /> o O EF �����''`�L -_ nJ,-.. r-}......_. .._.? ......../ BATT INSULATION BETWEEN ESOTNI;wAFOOTING SF�CHIM EY TO1 z <br /> :� --_OH 110CFM KITCHEN \ - "` i III I .^ \-_i / REMAIN.IF NECESSARY,POUR CONCRETE WALL MATCHING _I W <br /> v THICKNESS OF( STEM WALL TO HEIGHT OFill SILL. Lt: 0 <br /> % i 3 • j 4. (N ELECTRIC FIREPACE TO BE INSTALLED PERE MANUFACTURED <br /> / I 3�,. ;. -V-e•.._��IrJ__� -4!,41,,,L)).SD I I y c w o <br /> £I <br /> O O O ,3SPECIFICATIONS. `4i <br /> "' / I O O O REFR I ,�� j 1 \ /�.:I .q r ' Ir W LU ft N w ib <br /> I zE /�►48 CL / <br /> \ / "i- �� z is-15', :..:.~ :-::�/ 5 TRIMMER+ e1 STUD M EA.END.a a <br /> - \ (N)4. UOQ`(TO BE INSTALLED?ROME 9x8 HFf2 HDR W.(1) _ >- w Q <br /> / CL 30 €a60" / () w Q C <br /> / PANTRY U 30" /` o z I- 1' <br /> / cc <br /> �//n 30 - �4 48 ' 50CFM 6. (:)60^FRENCH DOOR TO BE INSTALLED IN(E)R.O.PROVIDE �. Y + rn <br /> / v 1 f �� / 4x8 HFg2 HDR W.(i)TRIMMER+(1)STUD EA EVD. (� w o w <br /> / \' , 2'-- i OATH SH \ j / ¢ N - ro w <br /> / SD BED 1 f • �J�=J / - (4)WINDOW TO MIRROR APPEARANCE OF ADJACENT FRENCH <br /> 3'S° <br /> / -. �� } �`y BED 2 / DOOR.PROV1DE(4 X 6)HF#2 HDR W.(1)TRIMMER+(1) <br /> / jQ 5 i ! 3 % STUD EA.END. Z Z <br /> / (� J <br /> / I I BAT • NIC 48 / j / T I EF) j 8 22"X 30"ATTIC ACCESS a <br /> N / I EF. / 42 ' / I I BATH SOCFM / <br /> 28" It; 3E° / � 0 <br /> -` // /50rFM ////////., ,/'/H-4-0 �/�/ O <br /> © 1-/// ////// ® ////// - \ ) O0) o <br /> a a <br /> 0 <br /> a <br /> ' <br /> G-6' 3-10 5'-1i" '7 10° 3'8' "10 4'-2" d'-8' 3' IC" <br /> 4.2" <br /> / / / / / /-/- / / / / ,r T / / / / <br /> 68'-4" i.-21^ 1.-2c . <br /> / <br /> 2 / <br /> . DRAWN BY - F.L. <br /> DESIGNER A.M.S. <br /> REV <br /> PROPOSED MAIN FLOOR PLANJOB NO. 17-016 <br /> D 1 2 4' $ JOB T J.:"....ry! <br /> 22x34:SCALE 1/4"=1'-0" - ' SCALE SEE SHEET11x17:SCALE 1/8"=1'-0" SHEET OFa <br /> A2.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.