Laserfiche WebLink
I <br /> 4 t 3 <br /> .x^^29. <br /> k X <br /> f "N=K'c0.r is , /4 kYrs d: 7,- t., ^' <br /> ,y <br /> 1 11, Supports for solar modules are installed to spread the dead load across as many roof <br /> framing members as needed to ensure that no point load exceeds fifty(50)pounds. Of 0 <br /> [IRC M2302,2.1(5)] <br /> i <br /> . 12. The photovoltaic modules and supporting structure shall be constructed of <br /> noncombustible materials or fire-retardant treated wood equivalent to that required for 11 0 <br /> i the roof construction.[iRC M2302.2,1] <br /> a <br /> 13, Roof and wall penetrations shall be flashed and sealed to prevent entry of water, <br /> 1 rodents,and insects,[iRC M2302.2.2] 0 <br /> ' '" <br /> I 14. PV modules are listed and labeled with a fire classification In accordance with UI.1703. <br /> [iRC M2302.2.31 " <br /> Comments: <br /> e If you answered yes to ail of the above questions,the project qualifies for the over-the- <br /> counter permitting process. <br /> i <br /> Determine if your project qualifies for an Over-the-Counter electrical permit <br /> p. <br /> 1 Yes No N/A. <br /> 1. PV modules,inverters,and combiner boxes are Identified for use In PV sytems. , L( C] <br /> 2. The Inverters are listed and labeled in accordance with UL1741and are listed d for � � <br /> utility Interaction, [IRC M2302.4] <br /> I <br /> 3, The AC interconnection point is on the load side of service disconnect. [NEC 690,64(8)] , <br /> 4. The system meets all current NEC,City and Washington Cities Electrical Code <br /> requirements. <br /> 5. For Split-Buss modules the AC Interconnection must be one of the six service 0 0 <br /> disconnects. <br /> 6. Maximum load added to the panelboard is based on the rating of the panelboards bus/main OCPi) <br /> combination in accordance with NEC 705.12(D)(2)(3)(b),and is limited to(check combination that <br /> applies): <br /> 0225 amp bus/200 amp main OCPD-13,440 AC watts,maximum 70 amp inverter OCPD. <br /> 0225 amp bus/225 amp main OCPD- 8,640 AC watts,maximum 45 amp inverter OCPD. <br /> IN200 amp bus/200 amp main OCPD- 7,860 AC watts,maximum 40 amp inverter OCPD, <br /> 0150 amp bus/150 amp main OCPD- 5,760 AC watts,maximum 30 amp inverter OCPD. <br /> 0125 amp bus/125 amp main OCPD- 4,800 AC watts,maximum 25 amp inverter OCPD. <br /> 0125 amp bus/100 amp main OCPD- 9,600 AC watts,maximum 50 amp inverter OCPD. <br />