My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
615 80TH ST SW 2022-01-03
>
Address Records
>
80TH ST SW
>
615
>
615 80TH ST SW 2022-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 3:30:11 PM
Creation date
6/28/2018 10:26:31 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
615
Notes
GEOTECHNICAL REPORT INCLUDED
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: pocock racing shells <br />Date 3/25/2017 <br />Exterior Lighting <br />Zone Table C405.5.2(1) <br />Specified by jurisdiction. <br />O Zone 1 ® Zone 2 O Zone 3 Ozone 4 <br />Zone selection required to enable LTG-EXT form <br />For Building Department Use <br />Calculation Area <br />0 p Addition - O Addition <br />stand alone + existing <br />o Alteration with < 50% ext. O Alteration with a 50% ext. <br />wattage replaced wattage replaced <br />Building Grounds <br />Applies to luminaires > <br />100 Watts <br />❑ Efficacy > 80 lumens/watt ❑ Exemptio <br />❑ Controlled by motion sensor <br />Tradable Maximum Allowed Lighting Wattage NOTE' Base Site Allowance: <br />600 <br />Tradable Surfaces <br />Surface Description <br />Area ( ), perimeter (If) <br />or # of items <br />AlloweO Watts <br />per fe or per If <br />Allowed Watts <br />x fe (or x If) <br />Other Entry Door <br />42 <br />20W/LF door <br />840 <br />Total Allowed Tradable + Site Allowance Watts: <br />1440 <br />Tradable Proposed Lighting Wattage "oTE s <br />Tradable Surface <br />Fixture Description NOTE 3, 4 <br />Number of <br />Fixtures <br />Wafts per <br />Fixture NOTE 5 <br />Watts <br />Proposed <br />Other Entry Door <br />LED waiipack, dark sky rated <br />5 <br />72 <br />360 <br />Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts: <br />n"- n1— 6" Ann.. n14. n)f..,..n..w.. An,. Agin ciin flllnu,flnnC nn+ nnnAAA in Mn1,0 <br />360 <br />tradable watts comply can be applied to individual non -tradable categories. <br />Non -Tradable Maximum Allowed Lighting Wattage "oTE' Site Allowance Remaining: <br />600 <br />Non -Tradable Surfaces <br />Surface Description <br />Area. (ft), perimeter (If) <br />or # of items <br />Allowed Watts <br />per fe or per If <br />Allowed Watts <br />x ft2 (or x If) <br />Non -Tradable Proposed Lighting Wattage "ore z <br />Non -Tradable Surface <br />Fixture Description NOTE 3,4 <br />Number of <br />Fixtures <br />Watts per <br />Fixture NOTE 5 <br />Watts <br />Proposed <br />Non -tradable proposed watts may not exceed allowed watts for any individual Non Tradable Watts Exceeding LPA: 0 <br />surface unless the total excess watts for all non -tradable surfaces are less than the Remaining Site Allowance: 600 <br />remaining site allowance. <br />Exterior Lighting COMPLIES WITH MAX. ALLOWANCE <br />Note 1- List all unique exterior sufaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop <br />down menu. <br />Note 2 - List all proposed lighting fixtures including existing -to -remain fixtures. <br />Note 3 - For proposed Fixture Description, indicate fixture type, lamp We, number of lamps in the fixture, and ballast type (if applicable). <br />Note 4 = Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage tables in the same manner <br />as new fixtures. Identify as existing in fixture description. <br />Note 5 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For <br />luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low <br />voltage lighting, enter the wattage of the transformer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.