Laserfiche WebLink
Project Title: <br />pocock racing shells <br />Date <br />3/25/2017 <br />Calculation <br />NOTE 8 <br />Area <br />O <br />O Spaces where < 50%of O <br />luminaires are replaced <br />Addition- O Addition <br />stand alone + existing <br />Spaces where a 5Qolo of O <br />luminaires are replaced - <br />For Building Department <br />Use <br />LPA <br />Calculation <br />Type <br />0 Standard O Additional Efficiency Package Option O <br />C406.3 Reduced interior lighting Power <br />To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. <br />Refer to C406.3 for additional requirements. <br />Maximum Allowed <br />Lighting Wattage <br />NOTE' <br />Building Area <br />Location (plan #, <br />room #, or ALL) <br />Area Description <br />Gross Interior <br />Area in fiz <br />Allowed <br />watts per ft? <br />Watts Allowed <br />(wattslfe x area) <br />Warehouse <br />boattmould storage <br />8000 <br />0.40 <br />3200 <br />Warehouse <br />parts storage <br />2762 <br />0.40 <br />1105 <br />Total <br />10762 <br />Proposed Li&htjR& Watts e <br />Building Area <br />Location (plan #, <br />room #) <br />Fixture Description rroTe z, 3, 4, 5 <br />Number of <br />Fixtures <br />a per <br />Fixture NOTE a <br />Watts Proposed <br />Warehouse <br />boat/mould storage <br />6 lamp T8 high bay fluorescent <br />15 <br />_ 192 <br />2880 <br />Warehouse <br />parts storage <br />2 lamp T8 fluorescent strip with wire guard <br />24 <br />64 <br />1280 <br />('mmnlianre by Ruihiincr Area NOTE7 <br />Building Area <br />Warnings <br />Total owed <br />Watts <br />Total ProposedInterior <br />Watts <br />Lighting <br />PowerAilowance <br />Warehouse <br />4305 <br />4160 <br />COMPLIES <br />Note 1- List all unique building areas per Table C405.4.2(1) that occur in the Totaisl 4305 4160 <br />project scope. Select building area category from drop down menu. <br />Note 2 - Proposed fixtures must be listed in the building area in which they occur. List all proposed lighting fixtures including exempt <br />lighting equipment and existing -to -remain fixtures. <br />Note 3 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the Fixture, and ballast type (if included). <br />For track lighting, list the length of the track (in feet) In addition to the fixture, lamp, and ballast information. <br />Note 4 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave WattslFixture blank. <br />Note 5 Existing -to -remain fixtures shall be included In the Proposed Lighting Wattage table In the same manner as new fixtures. Identify as <br />existing in fixture description. <br />Note 6 - For proposed WattslFixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For <br />luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage <br />lighting, enter the wattage of the transformer. For line voltage tracklbusway systems, enter the larger of the attached luminaire, wattage or <br />50 watts4ineai fart, or enter the wattage limit of permanent current limiting device. <br />Note 7 - Proposed Wattage for each Building Area type shalt not exceed the Allowed Wattage for that Building Area type. Trading wattage <br />