VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION
<br /> SEE SI-IEET 5 �OR .� , 3
<br /> GO�/ERED PATIO OPTIO� �� - - - - � � ���`� �cr � �
<br /> FOUNDATION NOTES:. ; � � 4�� , ,� a -�, �r-; �;;;,����
<br /> � � �, i � � 6
<br /> � �, �
<br /> � 6�_g�� i '-�2 i � a�_��� L ��-�z . .. �F.
<br /> 1. CONICRETE TO 8E 5 8ACK F�1S00 P81 �28 O�AY8 , , � '.
<br /> 4" GO lG. SLAB Oi�l � � �`�t1;r�• �"}_!!� ^.t J �+,�r�il�� 1
<br /> fr ��G�����TO���1���� I -F 4�� GRA�IEL �ILL 01 ,�:t,::� :�` I
<br /> START JOIST L� YOUT HERE �or���T eP.rz�+� ��T �'•_ t���= �,..�1. P��t�P+ �;
<br /> SLOP I/4"/�T. `_""`
<br /> ,�_:�:�.
<br /> BETTER ,PATIO � � �noe���r x�Pa�a►ix va�rrs � .w�- �
<br /> �*4 S B STEEL •°"""
<br /> 3. TO REST ON 1500 P.S.F. � �8' �.G. MAX. '
<br /> : � �
<br /> � � 1=4° � � � � � � , � ' " i i PI-4° � � a~,� `�,
<br /> — — — — — — _ — — — — - —
<br /> 4. MNd. OF$'lEEL TO 8E: - - � }---'k— . . � �
<br /> 4.1. �'CLEAR� BOTT011A OF FOOTIN(38 = - _ -
<br /> � � - - -a— L-- - - —� - � -�— - -� � - - - - - � � �
<br /> 42 1 �;�i1R�OIITSDE OF WALlB �v � , � � I � �, � �'� `� "'
<br /> 4� /4w�� �V�W� GARAI�E DOOR \ I �6�1��� - � � � � � � � � � � I i �` � • �
<br /> _ �
<br /> 5. ALL WM�Nr �ONTACT W/COIrCRE1E TO 8E ,'��.� I I i I I � I I I I I � � i I I I I I I I I I '" I � o
<br /> �� � �
<br /> 6. PROMDE 80l.� �1/EJt SUPPO�T'� .,�: � , � . i � 2�12 H�#2(� 16�O.C� THI$ SIE¢TIOM ON�Y � I � �X12 ,HF#� @ '�9.2 .C.�THI� SEC�TIO ON�LY � � � O
<br /> �. IN$TAI.L F�.�O� �1�INONE AI.L FORM8� Z -_-_=�=-=i--=-:-__- -
<br /> � ,,. __r===_:_._.u_v__
<br /> SD � _=-�����i- FI COMP.GFANU.AR I � I I I
<br /> w'� - - CF��4V1JL �P CE m
<br /> Q �������� 4' 8' 4' �F UOErNL BF104Y �` I � ' - r\
<br /> v� �� F�T�B�� �� 1e' � � 6�VaPOR e�w R EN I I I I I I I I I =� �
<br /> � I I I I I I I I I � I I I I I I I I I I I I I � � .
<br /> MNd. 8EL0'W�3R�DE U.N.O. DETAIL AT GARAGE DOOR = v
<br /> AL.L N OO�VVN8P"011T8 8F�1►LL�Y N�TO A ��'`''�' I� I I I I I I I I I � I I I
<br /> �. N _� -I(V �6 0 �-'-O° 4�_��� 3� 6�� �_6�� 7'-O" ��i �
<br /> 4"TI�CII� . EROF ��� sH�a� uo--r�: _ �� ��
<br /> T� F��AT��I N�AN SEE SHEET LI FOR SHEAR WALL - -� � �
<br /> LOGATIONS, SHEAR WALL -� �0
<br /> M���t z�ca�snr�e�o.c. NAILING SGHEDULE, � DETAILS. N � 8"W LL - -
<br /> ��. $F�.�.�����r wAT� 18' G � � � � � � � � � � � � �� t� � �
<br /> � � I I I I I I I I 4x10 D 4xi�D D x1 �� I 4x10 D�
<br /> 2x4 P.T.PLATE �
<br /> ��Q���IN���A�F�� HOLDOV�IN SGH�DUL� I I I I I I I I I � �tGJ � r�TG1 f I �FfG� �FTGJ L FTG2 �FTG1 - �
<br /> 4"CONC.SLAB � � �
<br /> NfARK i-IOLDOWN/ �ASTENERS TO � A,
<br /> . , . . , _ � � -� — �- - - -� - -1 � � � � - - � 0
<br /> RADE �_ ' � ST�'/�cP (2) STUDS MIN. U.N.O. � I � m = `V � �
<br /> i��. �`'_--=""�'`"=--'�'-_' I�G'I : 4x10 DF� I G2 I4x1�DFfif�2 I �'Z I 4x10�Ffif�2���r I 4�10 DF� I � I 4x10 DF� � 10 D ��T ,� m �
<br /> ANCHOR 60LT INFORMATION:_ � ��ul • c 4 FILLOMP GRANULAR --r-� STi-ID14/14 �.� «8�,«o,-��a � � � � � � � � � � � _ � � �
<br /> io J . :
<br /> � -� � � �� � �
<br /> a•DIA TIGHTLJNE � � ` �D T-Z MST48
<br /> �- - - -� �- - - -� �- — � - - J I I I r
<br /> ����y� � �/► ROOF DFiAIN REgqwF00nNG gCHEaA.E C�4)-I 6 d I I I I � � I I I I ' � I I I I I I I I I 0
<br /> 1• �������Ir�iIV\G ���N 4� � 4� 8AME AS DETAL BELOW I � � � �
<br /> T�p�T� �� T-� MSTA�F� (zF>>-IOd � , o., ._o��� I �, o�� I � �._��� � -7�_Q�� � �'-o" I I I �'-�"I I �Z, �� a
<br /> 1.1. !"j�YYb A.B. ���L��P� T-4 MSTG48B� (�8)-I Od � HEAD OUT R �li`-\,� -- ,-_ -----}--- -� _
<br /> 1.2. EN�ED MIN 7", NOT MOiZE TFiMI 8'APART FOR $GARAGE WALL DETAI L _ _, To' Er ''�__,%� � ;� `'` � FU�tN' � �
<br /> � �'a� SEE SHEET L-I FOR SHEAR WALL SGHEDULE Q (1� �-`---1"� ' ' WH�' ' ' I
<br /> OR 4 AP'/1RT FOR TVMO 8T�ORY _� _
<br /> , — �
<br /> ' � I I I I I I I I I �
<br /> � I i . --- `��---T---�
<br /> 1.3. (Z� �. PECEMIN. � � — - - ::Qi-2° — �. - - - - - - - � I i I I I I I I I �
<br /> 1��� (1)BOLT LOGITED NOT MOi�E TWW 12"OR�$ I—'� � (S)P A'!"�SDS � _I
<br /> TWW 7 B�LT D FROM EJ1iCM EI�PECE �� � , -- --- '� �
<br /> FOR1W�$TORY , U.N.O. 8" MIN. #4 VERT. HOOKBAR �
<br /> �.5. USE a UiARE PL,ATE W/18i�R8 AT GRADE a _ @ 48" O.C., CENTERED IN WALL - - OPT. 2'-8"DOOR ��
<br /> E�CH 60LT -1 I 1=1 I f=1 I I .�... - LOC., SPRF�4D o
<br /> �r� ANCHOR BOLTS � I , I I I I I I I I � —
<br /> � ���_i�— #4 HORZ. CONT., 12" MAX. I � gi I I I I I I I
<br /> FOUNDATION VENTILATION. '�=1 I I � . BELOW TOP OF WALL c� � �
<br /> ' • 'i-l�< ` FOR H>8' (2)#4'S IN TOP 12" � _ _ � � �
<br /> � o . -ICV � �-- � cV
<br /> :4 a..� � � MIN.36"X36�CONC � 6�W�L ]\ �� —I — I — I\
<br /> • �w��sT���o�rs w�oe.z j � . - —
<br /> w
<br /> • s 72 8QlJiAiiE N� °�,
<br /> LANDING(�OPTIONAL N 1 2 F T G i ��_��,� �
<br /> DOOR -1N GARAG E � �- o � �
<br /> • �oc3� so. Fr.* �,�oo=�.�sc��. * �.z�o�s�� _ � -
<br /> • 5�3.8 8 8 Q. I N./T Z s 8.Z 5 V E N T 8 R E Q I I I I i� a CRAWL GRADE IN�� '
<br /> ° I I I �-F' V �Y�nw�•�. f
<br /> • ����� �r� Fa�QAT���� � d — — (V � _ _ �Ol�3"t�OMW11q000R � 18'Pi x 18'DEEP
<br /> N CONC.FOOTING
<br /> �I I 1=1 I 1=1 I 1=1 I 1= � /
<br /> • 00 NOT PL/1�CE FOIJMQATION VENT8 IJNOER 80LlD I I 1=1 I I—I I I,' � � �
<br /> B�E�RING 111=111=111=11 =
<br /> • •FOlJ1�AT10N VENT8 SFl�l�ll 8E PLJ1Cm NRTHNd�OF `I I I I I I I I I I I I I I I I I 1- H W �, 6'-�" �� I I o •I -1 e"W� I 8, z„ �
<br /> 8 �.�Q� �(�������I,-I I ���' �6" - - �T G'4 _J -�' 16'FTG ,I� �� C Y
<br /> �,.I I I- 4'-8' 20" � � - _ Q�,
<br /> _ � 4" GONG. SLAB ON
<br /> � �
<br /> '� 8'�0 24� I I ((� ��1 4�� GRA�/EL �ILL ON
<br /> CRAWL SPACE• �� � I I = � X� SO��P�GT�E�RTH
<br /> -�N � � #
<br /> � ` $ ` � n � (v L-I (�V°' � 18�O.G MAX.
<br /> 1. 18"INMN.CRAWL 8PACE/R319.1 � 4 (2) #4 HORZ. CONT. _ _ �
<br /> 2 R�30 �ISULA '
<br /> � � FOOTING WIDTH (V1n � GONT. �OOTING
<br /> OPT. 2'�"DOOR b r � O.I-I, DOOR
<br /> �• �•���AT� � P R E S C R I PT I V E F N D. WAL L �CHOR BRO S � _ — _ -�D��o� SLAB` J = _, ,,r,, � �
<br /> 1/2" = 1�,�� � �►J —
<br /> GENERAL NOTES:. P,-�,'' �' P��s��
<br /> GARAG E �� �x Sn�Ds �2 2x Sn 5
<br /> E PLATES
<br /> Q PLATES
<br /> �. �L ���8� FR����i��A� � 5'-G" I F�'-��� ��_���
<br /> �N�J1iZWALl.B MUBT BE MISPECrED BEFOi�E 3�� �OPE���OOOR � �� z4'-o" � I�'-o" �
<br /> QQ�� r- STUD WALL og� q-o -o
<br /> , „
<br /> 2 PR�VDE 80L�BEARINQ�60TH END$OF ALL -i� ��� G
<br /> 8E/1RII�IG TF►IISSEB TO T1� � m3�
<br /> �� I � \ � (� v II'-6" v
<br /> 3. UPOER FLOOR INSPECTIONS REQUIRE�PRIOR TO FINISHED GRADE ' m � FLOOR JOIST N — — F O U N DAT I O N P LAN 2 1/2 CAR
<br /> �N$TALLATION SI'�ATHINC3 OR � �,-rTr� � PER PLAN �
<br /> , ��,������, � � . n _ �
<br /> 801L MVSTBE � '' ''%!%�%' - #4 HORIZ. CONT., 12 MAX g�yyqLL � SCi�E. 1/4 � � �
<br /> enac-Fw�oEVFxY. BELOW TOP OF WALL �
<br /> NO MORE TNAN 4 Ff. ; . .
<br /> DIFFERENCE IN SOIL �i � 12 FTG I FTG4 I
<br /> HEIGHTATANYI7ME a ' � �
<br /> a �������������,.
<br /> %i.//.�i,.//
<br /> � � � FOOTING SCHEDULE
<br /> o ` � � �-�
<br /> ? "' �#4 VERT. HOOKBAR �36" O.C. � � � �
<br /> p CENTERED WITHIN WALL r �OO.H. DOOR�G FTG1 2 -0 SQ. x 8 DEEP W/ (2) #4 IEACH WAY
<br /> o ` °` — — — — — — — — — — — — FTG2 2'-6" SQ. x 8" DEEP W,/ (3) #4 IEACH WAY
<br /> BI.OGONG(TYRCJ1l) � EDGE O� SLAB
<br /> �;•UL GRADE T8G PLYWOOD. GLUE � — — — — - — — — — — — — — — — — FTG3 3'-0" SQ. x 10" DEEP W/ (4) #4 EACH WAY
<br /> AND NAIL W/Sd 6"O.C.AT EDGES$ � �
<br /> SOLID BLOCKING. 10'FIELD IN FIELD �a \ \ / /
<br /> - - - - ,o,���,,,, FOOTING FOOTING � � � � FTG4 3'-6" SQ. x 10" DEEP W/ (6) #4 EACH WAY
<br /> u�suu►�P�su�o� DEPTH WIDTH --
<br /> - - - -- -- - - - (SEE�OUNDAT�Y e � � � � e 'P I�C�u
<br /> BM/POST CONNECTION � g�p�p�µ i� o� �.a aQ' �O��Z 2�O �4 P ATES��S 'C�J �X 9'�5
<br /> 2X4 OR 2X6 TIES �
<br /> (2}�lSd'S TO BM 8 POST � Z --- - PT 4%B'POBT W/1�00 FII.T ' I' '- " '- I' ` 11 3 LATES
<br /> EA.SIDE � � PAD ON CONC.F0071NG ��FOOTING -O 8 � � � � �� -� � -o , ALL COLUMNS SHALL BE 4 x 4 DF#1
<br /> 8 MIL BLAC.fC V18QUEFN m • �v��e•nev.c�o� M I N. (3 #4 FOR wironi �� � � �
<br /> � �"�0��� 20" & 24" �OOTING �o'-o"
<br /> �
<br /> � ,�. � ,a.�,�.��.�,�
<br /> FOUNDATION EXTENSION n �
<br /> � PROVIDE POSITIVECONNETION F O U N DAT I O N P LAN 3 CAR
<br /> FOOTING DETAIL `��M��� X TO SU ITABLE BEARI NG
<br /> �E�•.,�� Sx v2� _ ��-o� SCALE; 1/4" = 1'-0
<br /> S�ATTLE PACIFIC HOMES, INC. COPYRIGHT OC 2006
<br />
|