• Bio-Retention: It appeaft lat a selective placement of a bio-retentilhl Idcility should be feasible on the site. <br /> Please provide further justification in support of this infeasibility determination or select a different <br /> infeasibility criteria <br /> 2. The report section for Minimum Requirement#7 notes that the project is below the 10,000 SF threshold in the <br /> 2014 Ecology Manual. However,the City of Everett requires detention for all projects over 5,000Sf of effective <br /> impervious surface. Note though that this threshold is applied at the TDA level. Based on the information <br /> provided it appears that the project will be below the 5,000 SF level within each of the TDAs so flow control will <br /> not be required. Please update the language of the text to reflect this difference and the threshold <br /> determination. <br /> 3. Downstream analysis and plan. City GIS indicates that the storm drainage system in Lower Ridge Road drains <br /> east from the catch basin located near the southeast corner of the property. Please indicate the pipes <br /> connecting the catchbasins shown and the direction of flow. <br /> Erik Emerson PE <br /> City of Everett, Public Works <br /> Senior Surface Water Engineer <br /> 3200 Cedar Street <br /> Everett, WA 98201 <br /> Direct: 425-257-8995, Fax: (425)257-8882 <br /> eemerson@everettwa.gov <br />