EXIST. PAD MTD. _ 1 EXISTING_METER/MAIN O EXISTING_PANELBOARD
<br /> UTIL. TRANSFORMER --- — — '� —
<br /> „ ,_.,.0 PUD yA-12302 �� © 3
<br /> -. ° t,� t LLUJ UTIL XFMR © SERVICE POLE
<br /> �` SEE SHEET NOTE 1; I I O 1
<br /> SHEET E1.01 1
<br /> . DISCONNECT AND
<br /> ra.,,> REMOVE EXISTING100A/2P 60A 2P
<br /> 1 I /1
<br /> ., _<4 :.. 1, ao'„'rt� __ FEEDER - I / 6
<br /> xcc,,,,,';','-'-''',:-4:717;• •` .�,�a+ssb. .>. EXISTING
<br /> /
<br /> ..„. a;.-�.'`�a :” . k .sc.» z~ 3s ,'�+', A • 4 '. '4' "MARINA VILLAGE, r 11 /
<br /> e ' s • .. �' # `:' _ g - 7� 't •r, V* ,4 I WOODFlRE, I E E
<br /> Ay. r' . RI A ' j,�- r. [fi' 3
<br /> I ANTHONY'S"
<br /> ,- Pil .• ' MONUMENT 11 LOADCENTER_NEMA 3R
<br /> `.5 7 � i� �' .xis�i� A�.„� � _. - . _ 1'`-"z 4 `# ARC � � .. ._,k SIGN I - -\ - - -
<br /> $ ='+.,. "'Alt- iu' „,,,4--. < '_' ) 100A/2P MAIN
<br /> ..,t e 1s ...e - SERVICE PEDESTAL NEMA 3R
<br /> ,y ,r• ' - ".v _ SEE GENERAL NOTE 108; I 100A BUS, 120/240V, 70, 60HZ
<br /> !"' Js .—� © SHEET E1.01
<br /> O ".S • _ .s -- - I /Fl SPACES. IN.
<br /> Wit*,+ a:m. /
<br /> p 8 POLE /
<br /> _.- `.,,i-44"7 . -,, �. . 50A/2P MAIN I M
<br /> FIELD I I60A 2
<br /> EL VERIFY
<br /> I�... _ „a- - "sem"'" A I 100A BUS, 120/240V, 10, 60HZ I - - - - j
<br /> 4
<br /> _ " u= _ I I II 11 O ( 60.3 ) /
<br /> 4- 1 POLE ) // //!�
<br /> SPACES, MIN. /HELDVERIFY )20A/t / , . r////i /
<br /> EXISTING WAREHOUSE BUILDING EXISTING PANELBOARD EXISTING RESTROOM BUILDING — — — �fiz 60A/2P DISCONNECT AND
<br /> 0
<br /> O TIMECLOCK % ) REMOVE EXISTING
<br /> N.T.S. O N.T.S. O N.T.S.
<br /> SEXIST. O EXIST. RESTROOM FEEDER O
<br /> WAREHOUSE EXIST. SEWER SERVICE
<br /> 10 TO BE DEMOLISHED LIFT STATION DISCONNECT
<br /> •I EXISTING SUBMtIFJt 10 EXISTING UTILITY 0
<br /> ..ua'%R .._
<br /> (EMON—DEMON) TRANSFORMER - - —
<br /> 1 , I 10 SINGLE—LINE WIRING DIAGRAM — RESTROOM
<br /> i a 31{ NNYw 3}�5C'$ S x
<br /> J1 © SUB METER
<br /> t = [ S ' "`" - I I I I(DCN-DEMON)I
<br /> 4 a« Asa I y, I- _•, EXISTING ELECT. A
<br /> ° "&v ''^. .. •. I f ▪ ::.Six .♦. EQUIPMENT 4 M J XXA/2P I II
<br /> _ 'r,'x.l, Sze"'^.. ..:�""..,. '- I ®J
<br /> .- kms I _ _ ® —�— L COPPER FEEDER SCHEDULE
<br /> 1. '�wr"-- ▪ - FEEDER CONDUITS ® CONDUCTORS PER SET REMARKS
<br /> 3 &� ''.4.'',=';.",' ��a � 'e e'` k _ t p
<br /> .1 ',7`..,-
<br /> r."
<br /> TAG MET SETS RNC PHASE/NEUTRAL GROUND 05
<br /> �'"'a 4 } 3` I EXISTING XXA -
<br /> .`�kt � " _ f: I WEYERHAEUSER I ( 125.3 ) 125" 1 200' 3#1° #6
<br /> • t - 4 I BUILDING ( 11°.3 ) t.zs^ z.00" 3#z #6
<br /> -.. A ( 100.3 ) 1.25" 1 2.00" 33:22#2 #8 -
<br /> /
<br /> ( 90.3 ) 1 00" 1 1.50" 3#4 #8
<br /> EXISTING WEYERHAEUSER BLDG EXISTING WEYERHAEUSER BLDG EXISTING WEYERHAEUSER BLDG 10 — - - - ( 80.3 ) 1.00" 1 1.50" 3#4 #8
<br /> cp
<br /> O © © SINGLE—LINE WIRING DIAGRAM ( '0.3 ) '.°°" 5°" 3if4 #6
<br /> EXISTING UTILITY METERS SUBMETER BASEMENT ELECTRICAL EQUIPMENT WEYERHAEUSER BLDG ( 50.3 0.�5" 1 1.50" 3#8 #10
<br /> Ea N.T.S. N.T.S. N.T.S.
<br /> • ( 40.3 ) 0.75" 1 1.00" 3 08 #10
<br /> o ( 30.3 ) 0.75" 1 1.00" 3#10 #10
<br /> SHEET NOTES: ( 20.3 ) 0.75" 1 1.00' 3#12 #12
<br /> g, D NOT USED. O ( 15.3 ) 0.75" 1 1.00" 3#12 #12
<br /> 8 APPROXIMATE LOCATION OF EXISTING UNDERGROUND
<br /> 3 SERVICE CONDUIT,FIELD LOCATE. GENERAL NOTES(SCHEDULE).
<br /> I O DISCONNECT AND REMOVE EXISTING RESTROOM ELECTRICAL A.CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED
<br /> II SERVICE.REMOVE UNDERGROUND CONDUIT AND WIRE AS O LIGHTING TIMECLOCK:24 HR/365 DAY ASTRONOMIC ON COPPER CONDUCTORS W TH THHN TORI INSULATION.
<br /> B.PROVIDE NOTED SIZE GROUND CONDUCTOR N EACH CONDUIT OF
<br /> In NECESSARY TO ALLOW FOR NEW CONSTRUCTION. MECHANICAL TIMECLOCK WITH CONTACTS AS NECESSARY. FEEDERS CONSISTING O,MULTIPLE SETS^F CONDUCTORS.
<br /> °u_ TORK OR EQUAL. C.NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT.
<br /> RELABEL EXISTING BOA RESTROOM CIRCUIT BREAKER AS D.NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75^C
<br /> d 3 "SPARE".INSTALL NEW 20A,120V CIRCUIT BREAKER TO FEED 10 EXISTING WEYERHAEUSER BUILDING ELECTRICAL EQUIPMENT: TEREEDERONs.
<br /> E.ON FEEDERS SHOWN WITH A".6"SUFFIX,PROVIDE SIX PHASE
<br /> o NEW RECEPTACLE FOR RELOCATED WIRELESS ANTENNA. SEE GENERAL NOTE 10;SHEET E1.01 CONDUCTORS AND ONE GROUND WIRE IN CODE SIZED CONDUIT
<br /> NOT USED. INCLUDE 80%DERATING FACTOR ON PHASE CONDUCTOR SIZE.
<br /> 0 4
<br /> SCHEDULE REMARKS.
<br /> m OEXISTING 100A,240V,10 METER/TrINTO BE REUSED TO FEED 10 NOT USED
<br /> RELOCATED RESTROOM AND EXISTING SEWER LIFT STATION. ©NOT USED
<br /> 6 REMOVE AND REPLACE EXISTING 100A,120/240V,10 FEEDER n 30 REFER TO MCC AND PANEL SCHEDULES FOR FEEDER SIZES TO
<br /> °' EQUIPMENT NOTED WITH THIS TAG.
<br /> E WITH NEW 100A,1201240V,10 FEEDER TO NEW LOADCENTER..
<br /> t. ®"MET'=EMT,CRC(RIGID),RAC,OR PVC COATED GRC TYPE CONDUITS.
<br /> 3 0 RELOCATED EXISTING WIRELESS ANTENNA EQUIPMENT SEE RNC^=Pvc 40,PVC 80 DR FIBGERGLASS TYPE CONDUITS ROUTED
<br /> o SHEET NOTE 7;SHEET E1.01. UNDERGROUND.REFER TO SIZING ON DRAWINGS IF"RNC"CONDUITS
<br /> oARE ROUTED ABOVEGROUND.CONDUIT SIZES NOTED ON SINGLE-LINE
<br /> a DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER.
<br /> d OS PROVIDE GROUND WIRE NOTED ABOVE IN ALL FEEDERS AND BRANCH
<br /> o CIRCUITS.
<br /> 0
<br /> C.
<br /> 0
<br /> i
<br /> m
<br /> 6 IF THIS DRAWING IS NOT
<br /> 22"x34" SCALE ACCORDINGLY.
<br /> 0
<br /> 0
<br /> PROJECT ENGINEER: SCALE
<br /> p III ® III PND ENGINEERS,INC.IS NOT RESPONSIBLE FOR SAFETY I, E. DAVID AS NOTED PORT OF EVERETT DWG. N0.
<br /> oi PROGRAMS,METHODS OR PROCEDURES OF OPERATION,OR THE r
<br /> E1'02
<br /> �, CONSTRUCTION OF THE DESIGN SHOWN ON THESE DRAWINGS. DESICNEOBY: DATE3 Port of ENGINEERS,INC WHERE SPECIFICATIONS ARE GENERAL OR NOT CALLED OUT, j EJD/JRCJANUARY 2016 WATERFRONT PLACE CENTRALCIP N0.f a° I�I' � HRRBOR POWER THE SPECIFICATIONS SHALL CONFORM i0 STANDARDS Of N 3-8-003-02
<br /> EN 6 I N WS, INCEVERETT 1'36 Fowth Asenue S,SwmA INDUSTRY.DRAWINGS ARE FOR USE ON THIS PROJECT ONLY � / / DRAWN BY: CHECKED BY. WEYERHAEUSER BUILDING RELOCATION
<br /> a P.O.BOX sae Seattle,Washangon 98134 , /"\2/25/16 EJD ISSUED FOR BID AND AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN ' J. CAMPBELL EJD PROJECT
<br /> T PhAER,wn sazofi APPROVAL FROM PND. DRAWINGS ARE ALSO NOT TO BE USED ,2.1! ELECTRICAL DETAILS NO. — -2016-01
<br /> = ass zzv-�16a P:206-G24-138' CONSTRUCTION 1 APPROVE
<br /> ( ) IN ANY MANNER THAT WOULD CONSTITUTE ADETRIMENT
<br /> —
<br /> www.pndengineets.com DIRECTLY OR;NDIRECTLY TO PND.
<br /> w OPE PROJECT NUMBER: 2015-001 NO. DATE By REVISION a ' SHEET NO. 21 OF 21