Laserfiche WebLink
EXIST. PAD MTD. _ 1 EXISTING_METER/MAIN O EXISTING_PANELBOARD <br /> UTIL. TRANSFORMER --- — — '� — <br /> „ ,_.,.0 PUD yA-12302 �� © 3 <br /> -. ° t,� t LLUJ UTIL XFMR © SERVICE POLE <br /> �` SEE SHEET NOTE 1; I I O 1 <br /> SHEET E1.01 1 <br /> . DISCONNECT AND <br /> ra.,,> REMOVE EXISTING100A/2P 60A 2P <br /> 1 I /1 <br /> ., _<4 :.. 1, ao'„'rt� __ FEEDER - I / 6 <br /> xcc,,,,,';','-'-''',:-4:717;• •` .�,�a+ssb. .>. EXISTING <br /> / <br /> ..„. a;.-�.'`�a :” . k .sc.» z~ 3s ,'�+', A • 4 '. '4' "MARINA VILLAGE, r 11 / <br /> e ' s • .. �' # `:' _ g - 7� 't •r, V* ,4 I WOODFlRE, I E E <br /> Ay. r' . RI A ' j,�- r. [fi' 3 <br /> I ANTHONY'S" <br /> ,- Pil .• ' MONUMENT 11 LOADCENTER_NEMA 3R <br /> `.5 7 � i� �' .xis�i� A�.„� � _. - . _ 1'`-"z 4 `# ARC � � .. ._,k SIGN I - -\ - - - <br /> $ ='+.,. "'Alt- iu' „,,,4--. < '_' ) 100A/2P MAIN <br /> ..,t e 1s ...e - SERVICE PEDESTAL NEMA 3R <br /> ,y ,r• ' - ".v _ SEE GENERAL NOTE 108; I 100A BUS, 120/240V, 70, 60HZ <br /> !"' Js .—� © SHEET E1.01 <br /> O ".S • _ .s -- - I /Fl SPACES. IN. <br /> Wit*,+ a:m. / <br /> p 8 POLE / <br /> _.- `.,,i-44"7 . -,, �. . 50A/2P MAIN I M <br /> FIELD I I60A 2 <br /> EL VERIFY <br /> I�... _ „a- - "sem"'" A I 100A BUS, 120/240V, 10, 60HZ I - - - - j <br /> 4 <br /> _ " u= _ I I II 11 O ( 60.3 ) / <br /> 4- 1 POLE ) // //!� <br /> SPACES, MIN. /HELDVERIFY )20A/t / , . r////i / <br /> EXISTING WAREHOUSE BUILDING EXISTING PANELBOARD EXISTING RESTROOM BUILDING — — — �fiz 60A/2P DISCONNECT AND <br /> 0 <br /> O TIMECLOCK % ) REMOVE EXISTING <br /> N.T.S. O N.T.S. O N.T.S. <br /> SEXIST. O EXIST. RESTROOM FEEDER O <br /> WAREHOUSE EXIST. SEWER SERVICE <br /> 10 TO BE DEMOLISHED LIFT STATION DISCONNECT <br /> •I EXISTING SUBMtIFJt 10 EXISTING UTILITY 0 <br /> ..ua'%R .._ <br /> (EMON—DEMON) TRANSFORMER - - — <br /> 1 , I 10 SINGLE—LINE WIRING DIAGRAM — RESTROOM <br /> i a 31{ NNYw 3}�5C'$ S x <br /> J1 © SUB METER <br /> t = [ S ' "`" - I I I I(DCN-DEMON)I <br /> 4 a« Asa I y, I- _•, EXISTING ELECT. A <br /> ° "&v ''^. .. •. I f ▪ ::.Six .♦. EQUIPMENT 4 M J XXA/2P I II <br /> _ 'r,'x.l, Sze"'^.. ..:�""..,. '- I ®J <br /> .- kms I _ _ ® —�— L COPPER FEEDER SCHEDULE <br /> 1. '�wr"-- ▪ - FEEDER CONDUITS ® CONDUCTORS PER SET REMARKS <br /> 3 &� ''.4.'',=';.",' ��a � 'e e'` k _ t p <br /> .1 ',7`..,- <br /> r." <br /> TAG MET SETS RNC PHASE/NEUTRAL GROUND 05 <br /> �'"'a 4 } 3` I EXISTING XXA - <br /> .`�kt � " _ f: I WEYERHAEUSER I ( 125.3 ) 125" 1 200' 3#1° #6 <br /> • t - 4 I BUILDING ( 11°.3 ) t.zs^ z.00" 3#z #6 <br /> -.. A ( 100.3 ) 1.25" 1 2.00" 33:22#2 #8 - <br /> / <br /> ( 90.3 ) 1 00" 1 1.50" 3#4 #8 <br /> EXISTING WEYERHAEUSER BLDG EXISTING WEYERHAEUSER BLDG EXISTING WEYERHAEUSER BLDG 10 — - - - ( 80.3 ) 1.00" 1 1.50" 3#4 #8 <br /> cp <br /> O © © SINGLE—LINE WIRING DIAGRAM ( '0.3 ) '.°°" 5°" 3if4 #6 <br /> EXISTING UTILITY METERS SUBMETER BASEMENT ELECTRICAL EQUIPMENT WEYERHAEUSER BLDG ( 50.3 0.�5" 1 1.50" 3#8 #10 <br /> Ea N.T.S. N.T.S. N.T.S. <br /> • ( 40.3 ) 0.75" 1 1.00" 3 08 #10 <br /> o ( 30.3 ) 0.75" 1 1.00" 3#10 #10 <br /> SHEET NOTES: ( 20.3 ) 0.75" 1 1.00' 3#12 #12 <br /> g, D NOT USED. O ( 15.3 ) 0.75" 1 1.00" 3#12 #12 <br /> 8 APPROXIMATE LOCATION OF EXISTING UNDERGROUND <br /> 3 SERVICE CONDUIT,FIELD LOCATE. GENERAL NOTES(SCHEDULE). <br /> I O DISCONNECT AND REMOVE EXISTING RESTROOM ELECTRICAL A.CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED <br /> II SERVICE.REMOVE UNDERGROUND CONDUIT AND WIRE AS O LIGHTING TIMECLOCK:24 HR/365 DAY ASTRONOMIC ON COPPER CONDUCTORS W TH THHN TORI INSULATION. <br /> B.PROVIDE NOTED SIZE GROUND CONDUCTOR N EACH CONDUIT OF <br /> In NECESSARY TO ALLOW FOR NEW CONSTRUCTION. MECHANICAL TIMECLOCK WITH CONTACTS AS NECESSARY. FEEDERS CONSISTING O,MULTIPLE SETS^F CONDUCTORS. <br /> °u_ TORK OR EQUAL. C.NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT. <br /> RELABEL EXISTING BOA RESTROOM CIRCUIT BREAKER AS D.NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75^C <br /> d 3 "SPARE".INSTALL NEW 20A,120V CIRCUIT BREAKER TO FEED 10 EXISTING WEYERHAEUSER BUILDING ELECTRICAL EQUIPMENT: TEREEDERONs. <br /> E.ON FEEDERS SHOWN WITH A".6"SUFFIX,PROVIDE SIX PHASE <br /> o NEW RECEPTACLE FOR RELOCATED WIRELESS ANTENNA. SEE GENERAL NOTE 10;SHEET E1.01 CONDUCTORS AND ONE GROUND WIRE IN CODE SIZED CONDUIT <br /> NOT USED. INCLUDE 80%DERATING FACTOR ON PHASE CONDUCTOR SIZE. <br /> 0 4 <br /> SCHEDULE REMARKS. <br /> m OEXISTING 100A,240V,10 METER/TrINTO BE REUSED TO FEED 10 NOT USED <br /> RELOCATED RESTROOM AND EXISTING SEWER LIFT STATION. ©NOT USED <br /> 6 REMOVE AND REPLACE EXISTING 100A,120/240V,10 FEEDER n 30 REFER TO MCC AND PANEL SCHEDULES FOR FEEDER SIZES TO <br /> °' EQUIPMENT NOTED WITH THIS TAG. <br /> E WITH NEW 100A,1201240V,10 FEEDER TO NEW LOADCENTER.. <br /> t. ®"MET'=EMT,CRC(RIGID),RAC,OR PVC COATED GRC TYPE CONDUITS. <br /> 3 0 RELOCATED EXISTING WIRELESS ANTENNA EQUIPMENT SEE RNC^=Pvc 40,PVC 80 DR FIBGERGLASS TYPE CONDUITS ROUTED <br /> o SHEET NOTE 7;SHEET E1.01. UNDERGROUND.REFER TO SIZING ON DRAWINGS IF"RNC"CONDUITS <br /> oARE ROUTED ABOVEGROUND.CONDUIT SIZES NOTED ON SINGLE-LINE <br /> a DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. <br /> d OS PROVIDE GROUND WIRE NOTED ABOVE IN ALL FEEDERS AND BRANCH <br /> o CIRCUITS. <br /> 0 <br /> C. <br /> 0 <br /> i <br /> m <br /> 6 IF THIS DRAWING IS NOT <br /> 22"x34" SCALE ACCORDINGLY. <br /> 0 <br /> 0 <br /> PROJECT ENGINEER: SCALE <br /> p III ® III PND ENGINEERS,INC.IS NOT RESPONSIBLE FOR SAFETY I, E. DAVID AS NOTED PORT OF EVERETT DWG. N0. <br /> oi PROGRAMS,METHODS OR PROCEDURES OF OPERATION,OR THE r <br /> E1'02 <br /> �, CONSTRUCTION OF THE DESIGN SHOWN ON THESE DRAWINGS. DESICNEOBY: DATE3 Port of ENGINEERS,INC WHERE SPECIFICATIONS ARE GENERAL OR NOT CALLED OUT, j EJD/JRCJANUARY 2016 WATERFRONT PLACE CENTRALCIP N0.f a° I�I' � HRRBOR POWER THE SPECIFICATIONS SHALL CONFORM i0 STANDARDS Of N 3-8-003-02 <br /> EN 6 I N WS, INCEVERETT 1'36 Fowth Asenue S,SwmA INDUSTRY.DRAWINGS ARE FOR USE ON THIS PROJECT ONLY � / / DRAWN BY: CHECKED BY. WEYERHAEUSER BUILDING RELOCATION <br /> a P.O.BOX sae Seattle,Washangon 98134 , /"\2/25/16 EJD ISSUED FOR BID AND AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN ' J. CAMPBELL EJD PROJECT <br /> T PhAER,wn sazofi APPROVAL FROM PND. DRAWINGS ARE ALSO NOT TO BE USED ,2.1! ELECTRICAL DETAILS NO. — -2016-01 <br /> = ass zzv-�16a P:206-G24-138' CONSTRUCTION 1 APPROVE <br /> ( ) IN ANY MANNER THAT WOULD CONSTITUTE ADETRIMENT <br /> — <br /> www.pndengineets.com DIRECTLY OR;NDIRECTLY TO PND. <br /> w OPE PROJECT NUMBER: 2015-001 NO. DATE By REVISION a ' SHEET NO. 21 OF 21 <br />