BUILDING CODE G. PROVIDE 3"x3"x0.229"WASHERS AT ALL ANCHOR DOLTS. <br /> 2009 INTERNATIONAL BUILDING CODE CONCRETE D <br /> 7. BOLT HOLES SHALL SE NOMINAL DIAMETER OF DOLT PLUS <br /> P <br /> ROOF LOAD I#16" UNLESS NOTED OTHERWISE. LAG BOLT PILOT HOLES <br /> DEAD LOAD: 10 psf SHALL BE PRE-DRILLED TO 60%OF THE NOMINAL DIAMETER OF I . ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD <br /> FLAT ROOF SNOW LOAD: 25 psf THE LAG DOLT UNLESS NOTED OTHERWISE. ROCK TYPE(1 50 PCF)AGGREGATES SHALL CONFORM TO ASTM C33 WITH <br /> SNOW EXPOSURE FACTOR(Ce): 1.I PROVEN SHRINKAGE CHARACTERISTICS OF LESS THAN 0.05%. <br /> SNOW LOAD IMPORTANCE FACTOR(Is): I.0 8. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION <br /> THERMAL FACTOR(Ct): I.1 WITH 5#8" MINIMUM DIAMETER BOLTS SPACED AT A MAXIMUM 2. CONCRETE COMPRESSIVE STRENGTHS AT 28 DAYS (fc)SHALL BE: N <br /> OF 48"ON CENTER. BOLTS MUST BE EMBEDDED.A MINIMUM CONTINUOUS FOOTINGS: 2500 PSI 4; <br /> OF 7" INTO CONCRETE OR MASONRY. SEE PLANS AND DETAILS SLAB ON GRADE: 2500 PSI <br /> WIND DESIGN DATA PAD FOOTINGS: 2500 PSI 0 . <br /> I <br /> I. BASIC WIND SPEED: 85 MPH FOR SPECIFIC REQUIREMENTS WHERE APPLICABLE. O s <br /> 2. WIND IMPORTANCE FACTOR(Iw): I.0 EXTERIOR WALLS: 3000 PSI 0 m N <br /> BUILDING CATEGORY: II <br /> 9. RIM JOIST IS TO BE I I#4" LSL MINIMUM. " ALL CONCRETE EXPOSED TO WEATHER MUST HAVE AN fc >= 3000 PSI. >M N <br /> c mo <br /> 3. WIND EXPOSURE: B 3. ALL CONCRETE WITH A DESIGNATED COMPRESSIVE STRENGTH EXCEEDING 4T,•,t)2 <br /> 4. Kzt = 1.38 10. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITION ;c' m <br /> 5. INTERNAL PRESSURE COEFFICIENT: NA WALLS AND SOLID BLOCKING UNDER PERPENDICULAR 2500 PSI SHALL REQUIRE SPECIAL INSPECTION BY AN INSPECTOR APPROVED BY N 3 0 <br /> 6. APPLICABLE WIND PRESSURE FOR PARTITION WALLS. THE BUILDING DEPARTMENT AND THE ENGINEER. EXCEPTION: WHERE 3000 PSI 121 8 ti aL <br /> CONCRETE IS USED FOR WEATHERING PURPOSES, NO INPSECTION IS REQUIRED. wN v "r <br /> COMPONENTS AND CLADDING: NA I I I. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES L <br /> 2 <br /> SESIMIC DESIGN DATA TO THESE DETAILS 4. CEMENT SHALL CONFORM TO ASTM C 150,TYPE I, CSA NORMAL. U z <br /> D 0 <br /> I. SEISMIC IMPORTANCE FACTOR: 1.0 5. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. N i <br /> SEISMIC USE GROUP: I REINFORCING STEEL <br /> 2. SPECTRAL RESPONSE ACCELERATION(Sc): I 23.5%G G. PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 301. <br /> 3. SITE CLASS: D(ASSUMED) <br /> 4. SPECTRAL RESPONSE COEFFICIENTS(SDS): 82.3%G 1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A6 15 GRADE CO 7. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF <br /> 5. SEISMIC DESIGN CATEGORY: D (fy = GO KSI) FOR BAR SIZES NO. 5 $LARGER, GRADE 40(fy = 40 KSI) FIVE (5) DAYS AFTER PLACEMENT. ALTERNATE METHODS WILL BE APPROVED IF <br /> G. BASIC SEISMIC-FORCE-RESISTING SYSTEM: SHEARWALLS FOR NO. 3 AND NO. 4 BARS. SATISFACTORY PERFORMANCE CAN BE ASSURED. _ <br /> 7. DESIGN BASE SHEAR:SEE CALCULATIONS --- <br /> 8. SEISMIC RESPONSE COEFFICIENT(Cs): 0.089 2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE PLANS. 5. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL CASES.ALL --- <br /> 9. RESPONSE MODIFICATION FACTOR(R): 6.5 WHERE LAP OR SPLICE LOCATIONS ARE NOT SPECIFICALLY INDICATED CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND ALL LAITANCE ` <br /> 10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE ON THE CONSTRUCTION DOCUMENTS, LAPS AND/OR SPLICES SHALL BE SHALL BE REMOVED. ALL VERTICAL JOINTS SHALL BE THOROUGHLY WETTED AND '- <br /> 42 BAR DIA AND BE WELL STAGGERED. <br /> PROCEDURE SLUSHED WITH A COAT OF NEAT CEMENT IMMEDIATELY BEFORE PLACING NEW <br /> 3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 AND AI85 CONCRETE. <br /> FRAMING LUMBER AND SHALL SE 6X6 W2.9/W2.9 UNLESS OTHERWISE NOTED. LAP <br /> 1. FRAMING LUMBER SHALL BE HEM-FIR NO. 2. GRADES ARE REINFORCEMENT 6"MINIMUM. 9. POUR JOINTS SHALL BE LOCATED TO MINIMIZE EFFECTS OE SHRINKAGE AS <br /> TYPICAL UNLESS OTHERWISE NOTED ON PLANS. LUMBER TO BE WELL A5 PLACED AT POINTS OF LOW STRESS. MAXIMUM AREA OF POUR JOINTS IS <br /> GRADE MARKED PER WCLIB SPECIFICATIONS. 400 SF. LU - <br /> 4. ANCHOR DOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE LU > 0 <br /> SECURELY TIED IN PLACE BEFORE CONCRETE IS POURED. SLAB ON <br /> 2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD. 10. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR FORMED WORK 0 Q N <br /> GRADE REINFORCEMENT SHALL BE PLACED AT MID-DEPTH OF SLAB AND <br /> EXPOSURE I SHEATHING CONFORMING TO EITHER COMMERCIAL SHALL BE AS FOLLOWS: LU CO <br /> STANDARDS P5 1-83, APA PRP-108, OR VOLUNTARY PRODUCT SHALL BE HELD SECURELY IN PLACE WITH MECHANICAL DEVICES DURING EXPOSED TO EARTH OR WEATHER(#5 OR SMALLER): 11/2" OL w) <br /> PLACING OF THE CONCREETE. <br /> STANDARD PSE-92. PROVIDE A MINIMUM OF 3//' EDGE DISTANCE 'NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3"MINIMUM < 0 Q <br /> ON ALL NAILS AND/8" EXPANSION JOINT BETWEEN ALL PANEL GLUED-LAMINATED TIMBER COVERAGE 02 <br /> EDGES. MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS: <br /> ROOF SHEATHING TO BE'5/32"INT-APA RATED PLYWOOD ORI. ADHESIVE SHALL SE FOR WET USE. 1 I , PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN < W <br /> 7/6"OSB WITH EXTERIOR GLUE, P.I. 24/0. NAIL WITH 8d STRUCTURAL CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED. U 1 <br /> NAILS AT 6"ON CENTER AT PANEL EDGES AND 12"ONIll <br /> 2. LAMINATIONS SHALL BE OF DOUGLAS FIRNVESTER LARCH, <br /> CENTER AT INTERMEDIATE MEMBERS. 12. CONCRETE MIXES SHALL SE PROVIDED IN ACCORDANCE WITH ACI 318(WHEN - OL <br /> COMBINATION 24F-V4 FOR SIMPLE SPAN BEAMS AND 24F-V8 FOR 0 --. LL.7 <br /> CONTINUOUS MULTIPLE SPAN AND CANTILEVERED BEAMS, FABRICATED STRENGTH DATA FROM TRIAL BATCHES OR FIELD EXPERIENCE ARE NOT <br /> SUB FLOORING TO 5E3/4"TONGUE AND GROOVE C-D IN ACCORDANCE WITH AiTC A 190.I AND ASTM D 3737. AVAILABLE). W <br /> INT-APA RATED PLYWOOD OR OSB WITH EXTERIOR GLUE, <br /> P.I. 48/24. GLUE AND NAIL WITH I Od NAILS AT 6"ON 3. FABRICATION SHALL SE BY A LICENSED FABRICATOR;SHOP CEMENT CONTENT <br /> SACKS PER <br /> CENTER AT PANEL EDGES AND 12"ON CENTER AT DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL LDS/CUBIC YARD CUBIC YARD GOWN <br /> INTERMEDIATE MEMBERS. PRIOR TO FABRICATION. AITC CERTIFICATES OF INSPECTION ARE 0 *Ash.,CT <br /> F'e(PSI) (MINIMUM) (MINIMUM) CS of H. <br /> REQUIRED FOR ALL MEMBERS. 2500(no special ins •ection) 470 5 '�`<' • yc O <br /> 3. NAILING SHALL CONFORM TO TABLE 2304.9.1 OF THE p p 0 tr-Itei <br /> SEE NOTE A ,i,' ;af: <br /> INTERNATIONAL BUILDING CODE UNLESS NOTED OTHERWISE. USE <br /> COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. 3000 5 1 7 5'z _. - '',-' n ; <br /> 4. NO STRUCTURAL MEMBER SHALL SE CUT OR NOTCHED AIR ENTRAINMENT IS REQUIRED FOR ALL CONCRETE EXPOSED TO WEATHER. FOR 101,141. ' <br /> UNLESS SPECIFICALLY DETAILED OR APPROVED IN WRITING BY ."AGGREGATE AN ENTRAINMENT OF 6% IS REQ'D. FOR/2"AGGREGATE AN AIR 017 <br /> THE STRUCTURAL ENGINEER. ENTRAINMENT OF 7%IS REQ'D. <br /> 5. PROVIDE PROPERLY SIZED WASHERS UNDER HEADS AND NUTS MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5"OR LESS. NO Drawn By.CCC <br /> OF ALL DOLTS AND LAG SCREWS BEARING ON WOOD. MORE THAN A 1" PLUS TOLERANCE SHALL BE ALLOWED. Checked By:CCC <br /> 04-27-17 <br /> A)WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER SECTION 1704.4 OF Job No. 8056 <br /> THE I.B.C., CONCRETE SHALL HAVE A MINIMUM CEMENT CONTENT OF 5 SACKS <br /> PER CUBIC YARD OF CONCRETE. <br /> 5) ESIGN MIX(OTHER THAN A5 SPECIFIED IN THIS TABLE)SHALL BE SUBMITTED STRUCTURAL <br /> TO1HE BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST USE. NOTES <br /> 5- I .0 i' f' <br />