FOUNDATIONS GENERAL 5DP <br /> I.THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE I. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE <br /> INTERNATIONAL BUILDING CODE TABLE 1804.2. FOUNDATION WORK SHALL BE CONTRACT DRAWINGS. <br /> PERFORMED IN ACCORDANCE WITH CHAPTER 18 OF THIS CODE. <br /> 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL <br /> 2.THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE <br /> ALLOW. SOIL BEARING 1 500 PSF CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING, AND <br /> r. <br /> SOIL FRICTION .35 GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL to <br /> EQUIV. FLUID PRESSURES SAFETY ORDINANCES. ANY DEVIATION MUST BE APPROVED IN ��, <br /> ACTIVE PRESSURE' 35 PCF WRITING PRIOR TO ERECTION. m o- <br /> PASSIVE PRESSURE 250 PCF O N <br /> 3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA 30" m' \\`_A 0 ,. (-13. A.LL FOOTINGS SHALL BE FOUNDED AT LEAST 18"BELOW THE UNDISTURBED STANDARDS. ANY DEVIATION MUST SE APPROVED BY OSHA PRIOR REBAR \ 0 �`GROUND SURFACE OR TO FROST DEPTH. ALL FOOTINGS SHALL BE FOUNDED TO ERECTION. LENGTH ;,;t„� a_ON COMPACTED FILL OR UNDISTURBED NATURAL GRADE UNLESS OTHERWISE p,.!,..,.,;; ONE ##4 REBAR c ,<m:' / IN SHEAR CONE <br /> O M <br /> NOTED. 4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALLN 2-a NCONSTRUCTION PROCEDURES. (12” MIN. REBAR v ,3 Q <br /> 4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST OF LENGTH) 0 ` m <br /> THE EXCAVATED MATERIAL AND/OR IMPORTED BORROW AND SHALL BE FREE 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING 1/2" MIN. Fa <br /> OF ORGANIC MATTER,TRASH, LUMBER. OR OTHER DEBRIS. ALL WALLS SHALL THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. FROM CORNER �= m <br /> BE ADEQUATELY BRACED PRIOR TO BACKFILLING. FILL AND BACKFILL SHALL BE ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE o <br /> DEPOSITED IN LAYERS NOT TO EXCEED 8 INCHES THICK, PROPERLY MOISTENED ENGINEER AND BE RESOLVED PRIOR TO PROCEEDING WITH THE ' ' +-� <br /> TO APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY ROLLED OR WORK. O TH(� I N S TA I I A TI C�N <br /> COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER AND EXTENT AS <br /> TO PRODUCE A RELATIVE COMPACTION OF 90%OF MAXIMUM POSSIBLE G. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF <br /> DENSITY AS DETERMINED BY ASTM D 1557. HAND TAMPERS SHALL WEIGH AT. CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY <br /> LEAST 50 POUNDS EACH AND SHALL HAVE A FACE AREA NOT IN EXCESS OF INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, <br /> ' G4 SQUARE INCHES. HAND TAMPERS MAY BE OPERATED EITHER MANUALLY SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO ___ <br /> OR MECHANICALLY AND SHALL BE USED WHERE LARGER POWER DRIVEN REVIEW BY THE ENGINEER. --- <br /> COMPACTION EQUIPMENT CANNOT BE USED. STRUCTURAL FILL OVER 12" DEEP --- <br /> SHALL COMPLY WITH A GEOTECHNICAL REPORT. 7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL --- <br /> OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED OUT. TRUSS PER PLA --- <br /> ROOF TRUSS 8d © 6" 0/C INTO BLOCKIN • <br /> S. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO <br /> I. THE TRUSSES SHALL BE DESIGNED BY THE FABRICATOR TO FIT DIMENSIONS EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, H1 CLIP 0 EAC <br /> ' AND LOADS INDICATED ON THE PLANS AND IN THE STRUCTURAL NOTES. ALL BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL TRUSS (24" 0/C <br /> •DESIGNS SHALL BE IN ACCORDANCE WITH ALLOWABLE VALUES ASSIGNED BY CONDITIONS CONFLICT WITH THE DRAWINGS,THEY SHALL BE MA J11 _ <br /> THE BUILDING CODE. CONCENTRATED MECHANICAL ROOF LOADS SHALL BE REPORTED TO THE ENGINEER SO THE PROPER REVISIONS MAY BE U_J <br /> INCLUDED IN THE DESIGN. VERIFY WEIGHTS AND LOCATIONS WITH THE MADE. MODIFICATIONS TO CONSTRUCTION DETAILS SHALL NOT BE s / W > 0 <br /> aTHE <br /> ARCHITECT. SHOP DRAWINGS MUST BE RETAINED AT THE JOB SITE AND MADE WITHOUT PRIOR WRITTEN APPROVAL BY ENGINEER. VENTILATION MAY BE 0 < N <br /> AVAILABLE TO THE BUILDING INSPECTOR FOR REFERENCE. THE TRUSS WALL PER PLAN - REAT BLOCKING. W <br /> CALCULATION PACKAGE SHALL BE DESIGNED UNDER THE DIRECT SUPERVISION NAIL SHEATHING VERIFRIF Y METHOD W/ CZ <br /> OF A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON.THEQ <br /> INTO EA MEMBER OF ENGINEER PRIOR TO Ut 2 <br /> TRUSS ENGINEER SHALL ASSUME ALL RESPONSIBILITY FOR THE WORK OF ALL TOP PLATE CONSTRUCTION. BIRD <br /> SUBORDINATES INVOLVED IN THE PREPARATION OF THE TRUSS PLACEMENT BLOCKING IS I--. 1•--- <br /> PLANS AND THE TRUSS DESIGN DRAWINGS. ACCEPTABLE. < W _ <br /> 0 <br /> ROOF/SHEARWALL CONN. s ryw <br /> 2. SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED TO THE O — UJ <br /> ENGINEER FOR APPROVAL PRIOR TO FABRICATION. DRAWINGS AND > <br /> CALCULATIONS SHALL BE STAMPED AND SIGNED BY A REGISTERED in <br /> — lLl <br /> PROFESSIONAL ENGINEER. THE DRAWINGS SHALL SHOW ALL CRITICAL <br /> DIMENSIONS AS WELL AS THE LOADS THE TRUSSES ARE DESIGNED TO <br /> SUPPORT. THE TRUSSES ARE TO BE ERECTED AND INSTALLED IN ACCORDANCE <br /> WITH THE PLANS, APPROVED FABRICATOR DRAWINGS, AND INSTALLATION NAIL ROOF SHEATHING TO COV; <br /> SUGGESTIONS. CONTRACTOR SHALL GIVE NOTIFICATION PRIOR TO TOP CHORD w/ 8d 10 6" 0 C ti,vor`,,stiCh <br /> V � o� <br /> at <br /> ENCLOSING THE TRUSSES TO PROVIDE AN OPPORTUNITY FOR INSPECTION OF <br /> THE INSTALLATION. DESIGN AND PROVIDE BRIDGING BETWEEN THE TRUSSES, SHEARWALL PER PLAN fl'lit :' y r <br /> CONTINUOUS LATERAL BRACING AND DIAGONAL BRACING PER TRUSS PLATE I I <br /> INSTITUTE RECOMMENDATIONS. SHOP DRAWINGS MAY CONTAIN THE SILL PLATE AND ANCHOR BOLTS 2x FLAT ® GABLE SHEATHING TO MATCH c�R <br /> MANUFACTURERS ENGINEERING RESPONSIBILITY LIMITATIONS. HOWEVER,THEY PER SHEARWALL SCHEDULE. (USE IF SHEATHING IS NOT I SHEARWALL. NAIL TO ScIVALEt'¢," <br /> SHALL MAKE NO STATEMENT AS TO THE ENGINEER OF RECORD 2x6 P.T. SILL PLATE W/ %" 0 BROKEN ON TOP PLATE, • GABLE PER SCHEDULE. <br /> J-BOLTS W 48" 0/C MIN.) APR z , tU;i <br /> RESPONSIBILITIES. <br /> USE A35 © 12" 0/C <br /> II I BREAK SHEATHING ON <br /> I TOP PLATE ONLY Drawn by:CCC <br /> 6" � `I _ - �1 <br /> LATERAL BRACING IS Checked by:CCC <br /> 04-27-17 <br /> I 1I_ �' SHEARWALL PER PLAN -*--- -7-- <br /> I <br /> ' REQUIRED AT ALL GABLE <br /> 1'-6" I END TRUSSES AND IS TO Job No. 8056 <br /> III. <br /> I FROST IIFPTH 2" WIDE X 2'-0" DEEP CONT FIG <br /> BE DETAILED BY TRUSS <br /> w/ (2)# 4 ® TOP AND BOT. W/ MANUFACTURER <br /> BALANCE ® 18" 0/C — BEND SLAB STRUCTURAL <br /> 1'-O" REINF AROUND FACE AS SHOWN NOTES/DETAILS <br /> ®TYPICAL SLAB ON GRADE ®CABLE <br /> END/SHEARWALL CONNECTION .-9-4-V <br /> 5-2.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.