Laserfiche WebLink
VE�I�'Y LL INIENSI�NS �I�� T� C�NST� �CTI�N � <br /> �5,� . <br /> i'-io i/2" ` � <br /> ������ - � �. <br /> " ,' � a��� r r <br /> ���� ��� � �� �� I 2x TOP PLATE � . � �r�r�li� . �1�✓��Y9,iJ�YAs.'D� . <br /> HEADER • • HEADER� 3�INO.G. B.!^L ��� �P ��i�O�3�j�P�GTO� � c�, �:a-� <br /> � .°��I� I � EXTEND TO . . . . . ��„�.�4�-=s.,y� <br /> END I^L4LL5 . , . . � ;.:��'""` ' <br /> C�EN�RAL NOT�S:. I �, <br /> SEE PLANS TO DETERMINE'rHE DIFFERENT DESIGNATORS FOR SHEAR WALL MATERIALS, (�) 2x 5TUD5 <br /> NAILING,ANGHOR BOLTS,AND HOLDOWNS. LOGA'fE HOLDOWNS AS GLOSE AS POSSIBLE TO THE END <br /> OF THE DESI6NATED V^IALL. e <br /> ALL HOLDOWNS,ANGHOR BOLTS,WASHERS, 8 NAILS IN GONTAGT WITH P.T.NK70D TO BE •I I' � <br /> HOT DIPPED GAL�/ANIZED. <br /> PI = ONE SIDE PLYWOOD 'I I' � � <br /> P2 = TWO SIDES PLYWOOD 'I I' GONNEGT PLYWOOD � � <br /> W./8d NP.ILS � 3" O.C.. � � <br /> �/I6" NAIL SPAGIN6 TOP b BTM. A35 BLK6. SILL OPTIONAL BASE HEM FIR�2 �I • S�IEADERSDS, PLATES <br /> MARK P�ATE SIMP50N MASAP PLA7E VALUE • �� <br /> PLYWD. Ep�g FIELD P�ATES ANGHORS REQ'D. ANGfiOT2 SOLTS ANGHORS NAILIN6 (#/�._F) •I I• M1; • <br /> APA RATED SHTG. F�� � <br /> �8" MIN.24/O EXP. I <br /> PI-6" bd 6" 12" 6" 18"O.G. 2x4 5/8" � 48" � 48" 3 ENDS (2J Ibd � 10" 240 � �Y� <br /> PI-4" 8d 4" 12" 4" I6" O.G. 2x4 5/8" � 32" � 30" d ENDS (2) 16d � l" 349 �I � STHD14 WOOD � � <br /> TO GONGizETE p� <br /> PI-3" ** 8d 3" 12" 3" 14"O.G. 3x4 5/b" � 24" � 24" � ENDS (2) 16d �5" 450 � � GONNEGTORS OR W <br /> I• EGlUAL <br /> PI-2" *• 8d 2" 12" 2" 12" O.G. 3x4 3/4" � 24" � 18" 3 ENDS (2) Ibd � 5" 585 C3) #4 VERTIGALS I•II II. � <br /> I - 3x PLATE OR 2-2X <br /> P2-6" ** 8d 6" 12" 6" 10" O.G. 3x4 5/S° � 24" WA (2) Ibd �5" 480 �4 HotzlZ. � I'� • NAIL SHEATF-tING <br /> 12" o.c. TO EAGH PLATE \ <br /> P2-4" ** 8d 4" 12" 4" 8" O.G. 3x4 3/4" � 20" w/� (3I Ibd �5" �00 �i4���i x io��f+.s. C ' <br /> P2--3" ** 8d 3" 12" 3" 8"O.G. 3x4 3/4" � 16" IN/A �4) Ibd � 5" 900 D"V 3'X3^xV4" _ <br /> - GONG. PLATE WASHER - <br /> P2-2"*• 8d 2" 12" 2" 8" O.G: 3x4 3/4" � 12" NiA (4) 16d � 4" II�O Sy.�LL - 0 <br /> � � <br /> *'NOTE: WALLS WITi-I UNIT SHEAR OF 350�/ft.OR 6REATER SHALL HAVE FRAMIN6 �� o� • <br /> MEMBERS(STUDS 3 PLATES) ABUTTIN6 PANELS NOT LE55 THAN 3X MEMBERS �` � � <br /> PER IBG 2012,TABLE 2306.3.1. 3X FRAMIN6 WILL BE NOTED ON PLAN. � <br /> . GONT. FOOTING � <br /> I. USE PO��ER-DRIVEN STEEL S1UD5 AND NAILS BY HILTY OR RRMSET WHERE APPLIGABLE. � <br /> 2. PLYN100D MAY BE INSTALLED EI if1ER HORIZONTALLY OR VERTIGALLY. � <br /> 3. SOLID BLOGK WITH JOIST UNDER INTERIOR SHEAR WALLS. ELE�/.4TION �/IEl^1 <br /> SH�AR WALL NOT�S �P,RAGE�� GP.RP.GE <br /> DOOR � <br /> �/I6"OSS OR PLYNIOOD SHEATHIN6-USE 8d GOMMON OR 6ALVANIZED NAILS. BLOGK ALL PANEL <br /> EDGES. LONG DIMENSIONS OF PLYWOOD MAY BE INSTALLED�/ERTIGAI..LY.NAIL� 12" O.G.TO ALL <br /> INTERMEDIATE 5TUD5. N�HERE 3" NAIL SPAGING IS SPEGIFIED AT PANEL EDGES,U5E I-I/2" bd = <br /> SHORT NAILS OR BX STUDS WITH 8d GOMMON NAILS. �OR 2" NAIL SPAGIN6,USE 3X STUDS � <br /> AND STA66ER PANELS. WHERE PLYWOOD IS 2 SIDES OF 1NALL, JOINTS TO FALL ON �� <br /> SEPARftTE STUDS ON EAGH SIDE. INSIDE OF <br /> FLOOR PLYWOOD -USE 8d GOMMON NAILS� 10"O.G.AT INTERMEDIATE SUPPORTS,6"O.G. C�P.RAGE �w <br /> AT ALL PANEL EDGES AND 4"O.G.AT ALL SHEAR WALLS,UNLE55 OTHERWISE SHOWN ON PLANS. 1�L.4N �/IEYJ OP �i�,� <br /> FLOOR.lOI5T5-JOIST PARRALLEL TO FLOOR OPENINGS AA�D EXTERIOR WALLS SHALL BE GONG}ZETE 5"T"EM WALL �i � <br /> GRO55 BLOGKED AT 48"O.G.� ED6E5 W/{4) IOd NAILS FOR THE FIRST HAY. �� <br /> 3" x 3" x V4" SQUARE WASHERS AT ALL ANGHOR BOLTS. `� <br /> /� ^I ^ � � <br /> 7/I6"OSB OR PLYWOOD SHEATHIN6 -STAPLE SGHEDULE �V RTl'1L- �RP'1M� � <br /> ALL04^dABLE SHEAR�/ALUES WITFV HEM FIR�f2 STUDS � <br /> _ I RG R602.I0.6.2 <br /> 2" 16 6A.STAPLES� IS GA.STAPLES� 14 6A.STAPLES� L-I � � <br /> 3" O.G.-280 �/Pt. 4"O.G.-280#/ft. 4" O.G.-303�/ft. NO SGALE <br /> 2" O.G.-360#/ft. 2-I/2"O.C..- 430a/ft. 3"O.G.-3G0#/ft. <br /> 4" O.G. AND IOd NAILS 2" O.G. -504�/ft. <br /> � 6"O.G.-620�/ft. <br /> FIELD SPAGING: 12" O.G.NAILS 6 STAPLES. <br /> HOLDOWNS- INSTALL SIMP50N HOLDON�NS OR EG2UI�/ALENT AT THE END OF SHEAR WALLS <br /> WH€N SHOWN ON DRAWIN65. TO ATTAGH USE 2X OR 3X HF #2 GONSTRUGTION 6RADE5 AS <br /> SHEAR iNALL BOINJDARY ELEMENTS. HOLDOWNS ARE ONLY REG2UIRED WViERE SHOWN ON PLANS. <br /> 1`611507.3 4i�hole-housc mech�nic�l ventil�tion system. <br /> � Whole�house mechanical ventil�3tion systems shall be designed <br /> ��I� ���� '����� in accordance with Sections 1�I1�07.3.1 tlirough l�Ili07.3.7. <br /> I0'9�907.3.3 �ystem desi;n. Each dwzlling unit or guestroom <br /> � shall be equipped with a ventil��tion system complying with � <br /> �GLI M�T� ZON� 5 �ND M�f�l N� 4� Section M1507.3.4,NI1507.3.�,1�I1507.3.6 or NI1507.3.7. <br /> FENESTRATION SKYLIGHT GLAZED GEILING WOOD FRAMED FLOOR BELOW GRA:�E SLAB R-�/ALUE �. C0111�711i1I1C8 15 d150�7811II1tteCl t0 IJe C10ll10115tI�1teC1 tlIIOLl�i1 � <br /> U-FAG�"FO� ��-FAGTOR FENESTRATION iz-�/A.LUE 1^IALL R-�/ALUE R-VALUE YVALL 3Z-�/ALUE AND DEPTH C0111F7112IlC8 Wltll tile IIIt01112t10T181�8Ci1c�1llC21 COC�B. - <br /> t SFiGG <br /> /�� � o.so Hra R-4q R-21 �'� � io/is ra-io, 2 FEET 13�1507.3.2 Control :►nd oper:►tion. <br /> � � (R-38�lAULTED, � R-21 +TB <br /> � /���/ `-r 1 s stemotlshall be ieadily access Ule by thetoccupant. <br /> �`L��� : ` ��� y <br /> 1�I1507.3.5 Whole-house ventilation integrated with� <br /> TfaBLE 406.2 EHER.GY G•R�DITS Z. lnstructions. Operating instructions for 4vhole-house f�rced-air system. This section establishes minunum <br /> I-fOU5E5 BETI^1�EN isoo SQFT faND 5000 SQPT � ° ventilation systems shall be provided to the occupant by <br /> r-z�Qui� i.s �r-z�Di-rs prescriptive requirements fbr whole-house ventilation systems <br /> OP'TION � the installer of the.system. integrated with forced-air ventilation syst�ems. A system which <br /> o��_ov.�_ � 3. Local exhaust systems. Local exhaust systems shall be nleets all the requirements of this section shall be deenied to <br /> , , ...................______,�....,,....,..�.,,.,,.,�,.,,,,,,,�. ` � controlled by manual switches,deliumidistats,timers, satisfy the requirements fbr a whole-liouse,ventilation system. <br /> � . �g Sb EFFICIENT WATER FIEATING Sb: 1.5 or other approved means. <br /> �� IGIENT HUILDING EN�lELOPE la: MI507.3.51 Integratedwhole-house ventilation systems. <br /> � Water heatinQ system shall include one ofthe follo�rinQ: <br /> Prast�r•Iptiva aompllanae is basad on Table �2402.1.1 �ilth tha fol lorting modlflaatlons / � � 4. Contimious wholz-house ventilation systems. Inte ratedwhole-house ventilation s stems shall iovide <br /> FenasEr�tlon U .= 0.26 / Gas,propane or oil water heater with a minimum EF of0.82 Continuous whole-house ventilation systems shall g y p <br /> Floor R-3� �. ' or outdoor air at the rate calculated using Section iv11507.3.3. <br /> slab on gra�a tz-lo parimatar and �ndar antira s lab �' Solar water heatinQ supplementing a minimum standard water heater.Solarwater operate continttottsly. Exhatist fans,forced-air system Integrated forced-au ventilation systems shall distribute <br /> eeiow grada slab R-10 parlmatar ana undar antlra siab � fans,or su 1 fans shall be e ui ed�uith fan on as <br /> or � /'� heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the PP Y �1 pp <br /> Gomp Ilanca basad o. SBctlon R402.1.4: i�educa thB Total UA by S% outdoor air to each habitable space tln•ough the forced-air <br /> Solar Rating and Certific�tion Corporation(SRCC)Annual Performance ofOG-300 override controls. Controls shall be capable of system ducts. Integrated forced-air ventilation systems shall <br /> OPTION 3fi_ � Certified Solar Water Heating Systems operating the ventilation system without energizing have an outdoor an•inlet duct connecting a tei�ninal element <br /> HIGH EFFIGIENGY HVfaG EC�UIPM� lh�T: �r other energy=consuming appli�inces. A label shall be on the outside of flie building to the retum air plenurn of the <br /> Gas, propana or oIl-flrad furnaca wit`minim�m AFUE of GS%. �0;5 Electric heatpttmp waterheater with a minimucri EF of 2.0 and meeting the staridards of affixed to the controls that reads"Whole House � forced-air system,at a point within 4 feet upstream of the air <br /> To c��allfy to clalm thls cradlt, tha bulldlrsc� parmlt�,.��wings shall spaUfy th8 optlon batng (, NEEA'sNorthernClimateS ecificationsforHeatPum WaterHeaters o <br /> 98IBGtBGI and shal I spacify tha haating aqu! n�tylpe and the minlmum eq,uipmant afflUan y _ P P � Ventilation(see operati�i�insh-uctions)." � handler. T'he outdoor air inlet duct connection to the reY�un <br /> �j 5. Intennittent whole-house ventilation systems. air stream shall be located upstream of the forced-air system <br /> o�-rlot� �.�, Watzr heater heated by ground source heat pump meeting the reqttirements of Option IritertuiYtent whole-hottse ventilation s stems shall <br /> EF�IGIENT WA�'ER I-IEfaTING: 3C. Y blower and shall not be connected d'u•ectly into a fuinace <br /> Watar heating systam gha i i iny iv onB of tha following=,A � To qualify to claim this credit,the building permit drawings sha11 specify the option comply with the following: cabinet to prE:vent thermal shock to the heat exchanger. T'he <br /> o as, propana or ol I watafir� eitar rw�th a minlm�m EF of 0.62 '� being selected and shall s eci the water heater e ui ment t e and the minimum y p p g Y system will be equipped with a motorized damper connected <br /> � P fY 9 P YP 5.1, 'I`he shall be c,� able of o eratin internuttentl <br /> E leatrlc watar hB�qta��h a minlmum EF oF o.q3. equipment efficiency and,for solarwater heating systems,the calculation of the and continuously. to the automatic ventilation control as specified in Section <br /> and for both aa58s' <br /> � � minimumener��ysavings. <br /> a,i i showarhBa�t-ana kltahan slnk fa�aets Instal led in the house shall ratad at I.-IS GPM , � , „��,��,,,,DT��r r,,,,,nT���R,,,,��,. , �s � 5.2. They shall have controls capable of operating the M1507.3.2. `I11e required flow rate shall be verified by field <br /> or lass.�i�o£har lavatory fa�cats shall ba rated at I.O GPM or lass.� <br /> -ro c�u �sg to �ia�m this aradlt, the bvI ldlrig parmlt drawings sha i i spaufy the ap,=lon baing exhaust fans,forced-air system fans,or supply fans testing with a flow hood or a flow measuring station. <br /> sa�y�ad and shau spacify tha watar haatar aq.uipmant typa and tha minlm�m aq,�ment without energizing other energy-consuming M1507.3.5.2 Ventilation duet insulation. All supply ducts <br /> a�fEr"�iB�ny and shal I spaufy tha maximum flow ratas for a u showarhaads, kit�han srnk � ti> appliances. in the conditioned space shall be insulated to a minimum of <br /> cavcats, and othar lavator•y fa�aets. • <br /> � 5.3. T1�e ventilation rate shall be adjusted according to R-4. <br /> _---------- ' the exception in Section 403.8.51. M1507.3.5.3 Outdoor air inlets. .Inlets shall be screened or <br /> 5.4. T11e system shall b e designed s o that i t can operate otherwise protected from enh•y by leaves or other material. <br /> I �I p� �I � automatically based on the'type of control timer Outdoor aii•inlets shall be located so as not to take air from <br /> 1� � ���� I�l� ���C� � ����I�l��: <br /> installed. the fbllowing areas: <br /> 5EG710N 404 - ELEGTRIGAL POW�R d LIGH7ING 5Y5'TEMS 5.�. T'he intermittent mechanical ventilation systein 1. Closer than 10 feet from an appliance vent outlet, <br /> shall operate at least one hour out of every four. unless such vent outlet is 3 feet above the outdoor air <br /> 404.1 Interlor Llghting: A mintmum of "15 percent oP all <br /> luminarles shall be hlgh effleaey luminafrea 5.6. 'I`tie system shall have a mai�ual control and �n et. <br /> automatic control,such as a 24-hour clock tuner. Z. Where it will p ick up objectionable odors,fumes or <br /> ����I���I��I : flammable vapors. <br /> ��� 5.7. At the time of f'inal inspection,the�automatic <br /> 3. A hazardous or unsanitary location. <br /> control shall be set to operate the whole-house fa�i 4, A room or space havuig any fuel-buiivng appliances <br /> MI507.3 INTERMITTENTLY oPERATIN6 Y�NTILATION 5Y5TEM5. acco[ding to the schedille LlGed to calcillate the <br /> therein. <br /> THE DELIVERED VENTILATION RATE FOR IN7�RMI7TENTLY wholz-housef�an sizi�Ig. <br /> OPERATING VENTILATION 5Y5TEM5 SHALL SE THE 5. Closer than 10 feet from a vent apening of a <br /> GOMBINATION OF ITS DELIVERED GAPAGIY FROM TABLE 5,g. A label Silall 17e affltied t0 tile COritC01 tilat Te�idS p1ulilhiRg d1'a1R8ge SyStelll L1II18SS t�18 Verit Operilrig 1S <br /> MI5o7.3.3 (U,AND ITS VENTILATIoN EFFEGTIVENESS AND DAILY ALL HOT WATER PIPES IN UNHEATED SPAGES MUST ��VJI?ole Nouse Ventilation(see operating at least 3 feet abovethe air inlet. <br /> FRAGTIONAL oPERATIoN TIME FROM TASLE MI50'1.3.3(2) g� INSULATED WITW R--4 INSULATION PER 2012 WSEG SEG403.4.2 - instr«ctions)." 6. Atcic,crawl spaces,or garages. <br /> GOh1TIh10USLY Of'ERATING WHOLE HOUSE - <br /> FAhl TO BE LOGATED I N LAUh1DRY ROOM <br /> WITH FRESH AIR PRO�/IDED BY WINDOW ll'I1907.3.2.1 Oper�tin;insYpvetions. Installers shall provi e <br /> f'ORTS Ihl ALL Of'ERABLE 1^11h1DOW5 <br /> the nlanufactiner's inst�illation,o��erati�l�instructions,anc � <br /> �I� I �I� I I ����I��I : whole-house ventilation system oper�tion description. <br /> I�l �� I�l <br /> I�'I1�07.3.3 IVlechanie�l veiatilation rate. T17e whole-iouse <br /> P�RFORM BUILDING AIR LEAKAGE T�ST ('BLOW�R DOOR T�ST) mechanical ventilation system shall provide outdoor air to each <br /> IN AGGORDANGE 70 WSEG habitable space at a cont'uiuous rate of not less tl�an that <br /> PROVIDE DUGT SEALING AFFIDAVIT (IF APPLIGABLE) determined in accordance with Table NI15073.3(1). <br /> E�.�eption: T11e whole-liouse meclianical ventilation system <br /> is permitted to operate iuteimittently where the system has <br /> controls 1_1_lat enable operation for not less than 25 percent of <br /> each 4-hour segment and the veiitilation rate prescriL�e,d in <br /> Table NI1507.3.3(1)is multiplied by the factor determuied'ui <br /> accordance with Table M1507.3.3(2)• <br /> SEA�TLE �ACI�'IC ��I�NES, IIVCr C��Y�I��T � 20�� <br />