Laserfiche WebLink
Wrltten d(tnenslons ori thts drawing sFial) have precedence over *I ^ G ^*I ^G ^ G <br /> scaled dlmenstons. Gontactor shtrll verify aH dlmension�., I V�1JH �11 VD �1J�OG I�1T�J <br /> condlt(ons,etc.,pertalning to the work before proceeding. <br /> The Dwner muet be notiflec! pf any variations from the *I a ^ *I G <br /> dfinensions andlar concittlons shown on the�e drawings. Any G�I V�I`�1L I VOT�J: <br /> such varlatton sha(I be resolved tx� the Owner prlor to <br /> proceeding with the work,or the Gc�ntractor shall accept �� <br /> f�ll respea�slblllty for the cos't to rectlfy 5ame. �. f��� constructlon per applic�able GOG�eS Qf1G� ordinances. <br /> �(,��f�" 2012 I RG, I BG.-2012 !^lA5HIN6TON STATE ENER6Y GODE <br /> ROO�IN6 A�tATERIAL J 2. �erif all dimen�ion� on ob site. Brin discre ancles <br /> FINISH PER ELE�/ATIOP�i y � g f <br /> ON 7/16" OB5 50LID GDX 24-0 PLYWOOD to the attention of Owner and/or Designer. <br /> 5f-IEATHII�(G;8d � 6"O.G. EDGE -- <br /> 8d � 12" O.G. �IELD 3. Owner will verify window sizes and manufacturer(s) �lth <br /> ("t/16" 05B AGX PLYWD � E�/E5) �X ��43 framer before 5tart of c.onstructlon. <br /> 24" GlhRDBOf�R.D BA��LE MIN. IS# UNDERLAYMENT = <br /> ALLOW FOR I" AIR SPAGE �1,41L 6" ED6E, 12" �IELD � � 4. One window per bedroorn shall meet egress code. <br /> MIN. EXT�ND 12" ABO�/E YJITN 8d NAILS, U.N.O. HANDR�IL: fi- � <br /> INSULATION. GRI�' I/4" - 2" � <br /> PRO,JEGTIOh� �ROM 5. 5k�light glazing per 2012 IBG. <br /> \ WALL NO LE55 NOSII�C-� <br /> THAN Ii2". ----- 6. Truss manufacturer shall supp�y shop drawinc�� to Owner — <br /> �/'`" ._.a� Z and framer to review and approve before fabrlcation. � <br /> ..--y'fl � _ r #2 <br /> SpL11� �H�1�TNI1�� ' � � �1. Owner will verify electrical and heat layout5 w�th � ���I������ <br /> taR GDX P�YWD. - ( I installer before installation. {=__ � <br /> v�+��r� �x��s�p r c'� � � ���� <br /> 8. Under all arallel bearin walls, u5e double 015t5 or as <br /> TD lN�f�TNER c � I I P 9 � <br /> � noted on plan. Double �joist (or� extra TJII under call non- <br /> ( � ( bearin arallel walls. �n�� �?i;td�1`: ..�t`t a <br /> OPEN RAIL. I � � I 9 P �a'�'�,�a ��" ird��.as�:���, ;;P1 � <br /> T�p ��--• �'IGK�TS SH,�L�LEB��� ( � � � ` � �i. T_II rodu�ts to be instakled er manufacturer'� �'"` <br /> IX �ASGIA �I2, �m LE55 T+-+AN 4'" GLEAR � � i I � � i � �c installaEion guide and approved reports. <br /> W/ METAL - � � i � � � � � E� H,qNGER IO.AII metal connec.tions to treated wood shrafl be at a � `� <br /> 6UTTER � APPROVED TRU55E5 BEARIN6 � � ( r ,� f,/'� minimum; trip le zinc ZMAX (6185 per ASTi�i A653); Hot Dlp <br /> MANU�AGTURER'S SEAL. m � � � � / 6alvanze (ASTM A123 for connectors and A5TM153 for <br /> ; 5EE ROO� FRAMIN6 �'LAi�I _� ( � .�' <br /> i � � � fa�teners and anchors. <br /> ' —�OR 5�'AG1N6 " '� I I � <br /> � � ' ,Jf�� II. All bathroom fans, kitchen hood, and dr�er ducts shall be ,� <br /> INSULATE PER WSEG ��� � exhc�u�ted through the attic to the roof or through the � <br /> 2X BI RD BLK'G. W/ <br /> 2" SGREENED VENT �l°X 10" �NGHOR BOLT f�U 3"X3"X � floor ���tem to an outslde wall. All wail duc,ts shall � � <br /> s ,� /` (� terminate cat least 36° from a window opening. <br /> HOLES WITH I/4" �1." PLATE WA5HER5 � 48" o.c. t�U �' � �' <br /> GORR�'S10N RE515TANT �' � I �I �� ���� LE55 THAN 4f'�" f NO MORE THAN 12" 2X�f STC�F' -- �+ �✓-2x12 � � cn <br /> METAL MESH GO�/ERIN6 �ROM EA. END 51LL GORNER, .IOINT, STRIN6ER5 � � f l `� <br /> , END, O�'ENIN6 ETG. 7" M�N. � ( ) ��� S <br /> �� ��- �IRE BLOGK ALL VERTIGAL EMBEDMENT �NTO GONG. EXGEPT � 2-2X +-kEAD�R--� � GLIMATIG AND GEOGRAPHIG v � � � <br /> OPENII�l65 IN V�lALLS AT SH�AR 4^�I,hLLS - 5EE 5HE,4R WALL � DE51GN GRITERIA: O � <br /> PLATES AND �LOORS --NAILIN6 SGHEDULE. <br /> 2x P.T. 51LL-� ��-Q��` `��E�Tm�~~� �---2X4 BLOGKIN6 � � H <br /> � , (�IRESTOP) � TEF2MITE: 5LI6HT T� h�tODERRTE <br /> � - DEGAY: 5LI6HT TO MODERATE � � � <br /> z � WINTER DE51GN TEMP: I�t° °� r l "' � <br /> ' � �� � -#4 f�EBAR � 16" O.G. HORIZONTAL �---�IREBI_OGKS SJ IGESHIELL� R�QIlIRED: NO � v <br /> � - �I REBLOGK. STAI R5: <br /> � �NGINEERED �015T5, S�ZE AND � � . � FLOOD HF�ZARDS: 2003 Iqq2 �IRM C/� '�, <br /> ONGE I N TO�' � BOTTOM � � ,q <br /> 5�'AGING PER �LAN OR 2X J015T5 � O� RUN BETWEEN STRIN6ER5 � <br /> �I N. �LR. � � � �� � ALON6 RUi� BETWEEN 5TUD5 � � M AN AN UTAL EMP • 50 r� � <br /> -- #4 REBAR � 48 O,G. V�RTIGALa � <br /> USABLE 5�'AGE UNDER 5T,41R5 <br /> �+ TO B� ( HR �IRE GONSTRUGTION � ,':; <br /> �, S/&" TY�'E `X' 6.W.B. (TWO LAYERS _WW� <br /> Tpp p�., ' ° �F� M��• AT STAIR GEILING) � DESIGN DATA: <br /> e _ GLR. TY�'. <br /> i _.__ _._..___ _.� <br /> #4 REBAR ROOF LOADS: �L 25�/5F (5hlOW) <br /> �� „ <br /> (2) 2x TO�' �'LATE, �A�' GORNERS, � � �AR D1._ 15#/5F <br /> 0��5ET EN� .JOINTS �Y 48° TOTAL 40#/5F <br /> '� ALL �OOTIi*1G5 TO BEAR ON `^'�TA I R NO�E�"J: <br /> }3EARIP�d6 SoIL I I �� FLOOR LOAI�S: LL_ 4Q#I5F �� <br /> �" GY�'SUM 1^�ALLBOARD, TY�'. STJ�I� � ��T�I Ir `� TY�I G�Jr �I�ER HEIC-�HT = �1-�/4 M�X. <br /> 7�'b" 05B. OF2. �'LYWD. SHEATHIN6. � t^V iaVA �/APOR BARRIER � WALLS � TREf�D DEPTH = IO�� MII�I. p�- �O#/5F � <br /> NAIL 6" ED6E, 12" �IELD WITH �d ; AND G�1LIN65 <br /> NAILS UNLE55 NOTED OTHERvv15E i , �I �GALE: l�I.T.S. TO1�AL 50#/5F � <br /> � �T�. �L/V I�tL/�T I V 1�i ����( � DEGK LOADS: ����#/5F � <br /> �� SGAL�: ht.T.�. P�fiZ IRG R403.1,3 � R4C?3.1.3J TOTt�L �10#/5F � <br /> ' 1� I Y I I`l�� /"'l��/"'l 501L : !�C)O P5F MINIMUM � <br /> 2x 5TUD5 � I6° O.G. TY�',---- � � <br /> � <br /> �IRE BLOGK ALL �/ERTIGAL GONGRETE: 2500 P51 AFTER 28 DAYS � <br /> OPENIN65 IN WALLS AT {5%2 SAGK MIX) <br /> �'LATES AND �LOORS <br /> --3000 F51 FOR EXTERIOR FOUNDATION <br /> ` WAL1�_5, PORGHES, STEP�, AND OR <br /> C�ARAGE SLAB{�- AIR ENTRAI�iMEN`f" � <br /> 15 BETWEEN 5--19`0 (TABL� 402.2 IRG) <br /> i �"X 10" ANGHOR BOLT WJ 3"X3"X �" � / � � <br /> 51DIN6, 5EE �'LAN �OR TY�'E � �'LATE WASHEF�S � 48" c�.c.. NO LE55 ` � J <br /> THAN 4�° 8 NO MOR� THAN 12" MA50NRY : PER 2012 IBG � <br /> FROM EA. END 51LL GORNER, ..lOINT, � ^ ���� STE�L. : �'ER 2012 IBG (6RADE 40) � <br /> ENT7, O�'EWI�t6 ETG. �7" MIN. <br /> EMBEDMEt�T INTO GONG. EXGE�'T � E �-� <br /> SHEAR WALLS - 5�� SHEAR WALL WOOD : PER 2012 IBG <br /> NAILIN6 SGHEDULE. � NAILIN6 : PER 2�12 IRG NAILIN6 �'ER TABLE <br /> ; R602.3(I), R�S02.10 <br /> TOP �L.AN6E J015T WIND: &5 MPH <br /> ' HAN6ER �'ER t'LAN ' <br /> 5E15MIG: 5EE �ALGUL��`ION PAGKET <br /> 2x BOTTOM �'LAT�—� �i�" T#6 �'LYINODD SIJB-�LOOR <br /> 2x �'.T. 51LL_ C6LUED � N,hIL�D) NAIL 6" ED6E, -_INSULATE �'ER WSEG., <br /> WEATH�RINC� POT��iTIAL: MODEf�TE <br /> � 12" �IELD W/ lOd NAILS. , 5�"JLID BLOGKING � date: O"t OI O <br /> �I N. FLR. BR6. WALL ABO�/E TYP. ; permtt. <br /> \ � _ � ! FR05T LINE: 12° revlslc�ns: <br /> - �` __ � _ __- -- ___ .__-___ 4�� GONG�. SLAB i <br /> — _.. - -- - _ _._. _ _ — _ ____ , E.F.P.: 45 P5F <br /> 4"� D.�. TIC�NTLIN�, PC?�1TIV� � t� � �a o � 4" BEAM: DOU6LA5 FIR #2 <br /> 1�Rt�,IN TC� �TORM SYST�M I�°. �' ��I �` � If 6�� BEAM: fv = 85 <br /> �IN. �RAL�� TC� 5L�?P� � � �. ;" _ ___ _� _. _..— ',Q' -��I a � a. � � <br /> AW.BSY FRC�M BUILDIN� _ - �— — � — ( E�='1,600,000 <br /> = �_ �— 4 � � 4" P05T: DOU6LA5 FIR �� <br /> I � �i � F�i �-���' <br /> EN6INE�RED J015T5, 51ZE AND � � �" f'05T: fv � 85 <br /> 4-g'I �f��. Gi��1�1�5��G� 5�'AGING F'�R �'LAN, a fb = 8`f� P51 <br /> � = 1,300,000 <br /> `�!�!� I I—I � I� � �NBALANGED r i � A # <br /> ' I I�j ' I�� � �� (TALLER W,hLLS PER PLr�N) 5E� �OUT�IDATION F'LAN � .�O 5T5 R FTERS HEM �(R 2 <br /> �� � I-� k �—� Q �OR BEAM 51Z� � 2x4 6U55ET EA. 51DE � 5TUD5: fv = �7� <br /> � � P05T 51ZE / SPAGIN6 � E = I,�00;00 Ghec.ke�'by: RO <br /> • �I ( ��— � j REBAR t'LAGEMENT <br /> � � � j�I "51M�'S0N" A35 OR 51MILIAR <br /> � �_I � --SEE DETAIL #2 ABO�/E qp# �ELT �o��r To coN�. 6LU-LAM BEAMS: �HEET <br /> � _....�' , I—f I � 4 � fv = 165 psi <br /> � � -� � — � fb = 2,400 psi (reduc.ed by size <br /> a aQ �. <br /> � � � <br /> � -� � '-= v � }- b N[IL. PC�LY VAPG�i�. 8t�1�.RI�R � � "' � factor, GF�KI) <br /> � � �� < ° � � �� ��',�— ° �' �, �° � � = i��oo,000 psi <br /> � __ ``�-__�__-- _ <br /> ___ — <br /> � _ �{ d NOTE: <br /> � � ALI� REINFc�F2GEMEhJT VARIATIONS FROM Tf-IE ABOVE <br /> � MUSr B� TI�I� Ihl PLI��� LUMBER GRADES YVILL BE <br /> �t�� �Ol1ND,4Tl�t� INSPEGITON <br /> NOT�I� ON THE F�LANS. <br /> 5EE �OUNDATION PLAN - 5�� �OUNDATION PL.AN <br /> �OR �T6. 1 �DN. 51ZE �OR �'P� 51ZE <br /> I. 5U8FLOOR: <br /> ALL �OOTINC�S TO BEAR ON ALL �OOTIN65 TO BEr4R ON �T`�6 PLYt^IOOD OR 05B APA RATED <br /> BEARING 501L BEARIN6 501L STURD-I-FLOOR 16" O.G., 3/4" <br /> INALL � F:OOF SH�ATHIN6: <br /> APA R,�TE� SHEATIN6 24/I6 �t/I��° <br /> FOOTIN6 FOR : <br /> � T`r'"�I ��1.. ��1.�. S��T I c�l�� �" WALL - 1181'XBELOI�I o6RADE <br /> �I �GP�L.E: t�l,T.S. <br /> #4 STUB STEEL - 48" o.c. VERT. <br /> Ui�1L��`�� NOTED O`�-E-IERWI�E <br />