Laserfiche WebLink
' Prescriptive Energy Code Compliance for Climate Zones 6,5 and Marine 4 <br /> Project Information Contact/nformation <br /> Plan 2319 Nash and Associates Architects <br /> 425-828-4117 ext 105 <br /> This projectwill use the requirements of the Prescriptive Path below and incorporate the <br /> the minimum values listed. In addition,based on the size of the structure,the appropriate <br /> number of additional credits are checked as chosen by the permit applicant. <br /> Authorized Representative ___ _Date <br /> Climate Zone 5 8� Marine 4 6 <br /> R-Valuea U-Factora R-Valuee � U-Factora <br /> Fenestration U-Facto� n/a 0.30 n/a 0.30 <br /> Skylight U-Factor n/a 0.50 n/a 0.50 <br /> Glazed Fenestration SHGCb�e n/a n/a n/a n/a <br /> Ceiling 49� 0.026 49 0.026 <br /> Wood Frame Wall9�k�' 21 int 0.056 21+5ci 0.044 <br /> Mass Wall R-Value' 21/21h 0.056 21+5h 0.044 <br /> Floor 30° 0.029 309 0.029 <br /> Below Grade Wall°'k 10/15/21 int+TB 0.042 10/15/21 int+TB 0.042 <br /> Slabd R-Value 8� Depth 10, 2 ft n/a 10, 4 ft n/a <br /> "Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. <br /> Each dwelling unit in one and two-family dwellings and townhouses,as defined in Section 109.2 of the <br /> Intemational Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the <br /> following minimum number of credits: <br /> �1.Small Dwelling Unit: 0.5 points <br /> Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration <br /> area. Additions to existing building that are less than 750 square feet of heated floor area. <br /> �2.Medium Dwelling Unit: 1.5 points <br /> All dwelling units that are not included in#1 or#3, including additions over 750 square feet. <br /> ❑3. Large Dwelling Unit: 2.5 points <br /> Dwelling units exceeding 5000 square feet of conditioned floor area. <br /> Table R406.2 Summary <br /> O tion Description Credit s <br /> 1a EfficientBuildingEnvelopela 0.5 � <br /> 1 b Efficient Building Envelope 1 b 1.0 � <br /> 1 c Efficient Building Envelope 1 c 2.0 � <br /> 2a Air Leakage Control and Efficient Ventilation 2a 0.5 � <br /> 2b Air Leakage Control and Efficient Ventilation 2b 1.0 � <br /> 2c Air Leakage Control and Efficient Ventilation 2c 1.5 � <br /> 3a High Efficiency HVAC 3a 0.5 � <br /> 3b High Efficiency HVAC 3b 1.0 � <br /> 3c High Efficiency HVAC 3c 2.0 � <br /> 3d High Efficiency HVAC 3d 1.0 � <br /> 4 High Efficiency HVAC Distribution System 1.0 � <br /> 5a Efficient Water Heating 0.5 � <br /> 5b Efficient Water Heating 1.5 [,,] 1.5 <br /> 6 Renewable Electric Energy 0.5 "1200 kwh 0.0 <br /> Total Credits 1.50 <br /> *Please refer to Table R406.2 for complete option descriptions <br /> httq://www.ener�v.wsu.edu/Docume nts/2012%20Res%20Ener�v.pdf <br /> . <br />