Laserfiche WebLink
� Table R402.1.1 Footnotes <br /> For 51: 1 foot :304.8 mm, ci : continuous insulation, int =intermediate framing. <br /> 'R-ValUeS are minimUms. U-fa[tor5 and SHGC are maximums. W hen insulation is installed in a cavity which is <br /> less than the label or design thickness of the insulation,the compressed R-value of the insulation from <br /> Appendix Table A101.4 shall not be less than the R-value specified in the table. <br /> °The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. <br /> Exception:Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 <br /> through 3 where the SHGCfor such skylights does not exceed 0.30. <br /> `"10/15/21.+TB" means R-10 continuous insulation on the eu[erior of the wall, or R-15 on the continuous <br /> insulation on the interior ofthe wall, or R-21 cavity insulation plus a thermal break between the slab and the <br /> basement wall atthe interior of the basementwall."10/15/21.+TB" shall be permitted to be met with R-13 <br /> cavity insulation onthe interior ofthe basement wall plus R-5 continuous insulation on the interior or <br /> exterior ofthe wall. "10/13" means R-10 continuous insulation on the interior or exterior ofthe home or R- <br /> 13 cavity insulation at the interior ofthe basement wall."TB" means thermal break between floor slab and <br /> basement wall. <br /> ° R-10 continuous insulation is required under heated slab ongrade floors.5ee R402.2.9.1. <br /> °There are no SHGC requirements inthe Marine Zone. <br /> �Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table <br /> R301.1. <br /> s Reserved. <br /> ° Firstvalue is cavity insulation, second is continuous insulation or insulated siding, so "13.+5" means R-13 <br /> cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent <br /> or less ofthe exterior, continuous insulation R-value shall be permitted to be reduced by no more than R-3 in <br /> the locations where structural sheathing is used to maintain a consistent total sheathing thickness. <br /> 'The second R-value applies when more than half the insulation is on the interior ofthe mass wall. <br /> ' For single rafter-orjoist-vaulted ceilings,the insulation may be reduced to R-38. <br /> k Int. (intermediate framing) denotes s[andard framing 16 inches on center with headers insulated with a <br /> minimum of R-10 insulation. <br /> � Log and solid timberwalls with a minimum average thickness of 3.5 inches are exempt from this insulation <br /> requirement. <br /> Table R402.1.3 Footnote <br /> ' Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as <br /> specified in Section R402.1.3. <br />