Laserfiche WebLink
r ' � <br /> � � SNOHOMISH <br /> HEALTH DISTRICT <br /> WVJW.SNOHD.ORG Environmental Health Division <br /> December 19, 2014 <br /> Frank Karreman <br /> 231 Gowen Place NW <br /> Bainbridge Island WA 98110 <br /> Subject: Proposed Jersey Mike's Subs, 4817 Evergreen Way, Everett <br /> Dear t�lr. Karreman: <br /> Your plans have been reviewed with the Rules and Requiations of the State Board of Health, and with <br /> the policies of the Snohomish Health District. Wi;h the addition of th= following conditions, the plans <br /> are approved. <br /> 1. The conditional approval of the plans for Jersey Mike's Subs was based upon the plans <br /> submitted November 19, 2014, the menu submitted November 20, 2014, and HACCP submitted <br /> December 11, 2014. Any changes to the pians submitted November 19, 2014, the menu submitted <br /> Novem6er 20, 2014 and HACCP submitted December 11, 2014 wiil void this approval. <br /> 2. The Health District operating permit application process must be completed prior to opening for <br /> business. This facility will be classified as a high risk food establishment wilh 51-150 seats. <br /> 3. Three-compartment sinks must be NSF or equivalent Iisted v✓ith integral drainboards at both ends. The <br /> basins of the ihree-compartment sink must be large enough to fit the largest item needing to be �vashed. <br /> 4. An indirect waste drain (an air gap) is required for the food preparation sink, three-compartment sink, ice <br /> machine, pop dispenser, walk-in refrigeration, and any equipment in which food is placed. Please note <br /> that a direct drain to a grease trap is ne:considered an indirect drain even if the grease trap is indirectly <br /> drained. <br /> 5. A reduced pres����e backFlow prevention device is required at the end of the copper water pipe serving <br /> the pop dispensing system prior to the carbonation device. No copper or brass pipe/fittings or other <br /> potentially corrodible material is allowed after the reduced pressure backflow prevention device. <br /> 6. Each food preparation sink must be NSF or equivalent listed with at least one integral drainboard. <br /> 7. Only one food preparation sink is indicated on the floor plan. Because of this only vegetable preparation <br /> will be allowed at this sink. No rinsiny or thawing under running waler of raw meat, poultry, andlor <br /> seafood will be allowed without the installation of an additional and separate food preparation sink. If <br /> installed, the location of any additional food preparation sink must be approved prior to installation. Tf•�e <br /> sink must be NSF listed or equivalent and have at least on integral drainboard. <br /> 8. A horizontal separation oF at least 16 inches or a vertical partition 16 inches in height is required <br /> behveen the handwash sink and ali food preparation areas. <br /> 9. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required <br /> between the workroom handwash sink, item #13, and the stainless steel work table, item #30A. <br /> 10. When splashguards (partitions and/or walis) are provided on both sides of a handwash sink the distance <br /> between the splashguards must be at least 18 inches apart (shoulder width) to aliow proper access to <br /> ihe handwash sink. <br /> 11. Water heaters must be of su�cient size to provide hot wa?er to dishwasher andlor scullery sinks and at <br /> the same time provide hot water to afl handwash sinks. <br /> ����1 U�� �/� <br /> 3020 Rucker Ave��ue, Suite 104 � Evereft, wA 98201-3900 � tel: 425.339.5250 � fox: 425.339.5254 <br />