Laserfiche WebLink
Subject: Proposed Jersey Mike's Subs, 4817 Evergreen Way, EvereK <br /> Decemb2r 19, 2014 <br /> Page 2 <br /> 12. Hot water must be available to all handwash sinks v�ithin 15 seconds. The hot water for the facility must <br /> not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. <br /> This is reqwred so that proper testing of the 15-second time requirement for hot water availability c2n be <br /> completed. <br /> 13. All food service equipment, both new and used, must be listed by the National Sanitation Foundalion <br /> (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of holding food at <br /> temperature of 41°F or below. <br /> 14. Used equipment is subject to onsite inspection to determine acceptabiliry for use in the proposed food <br /> service establishment. Used equipment must be ciean, in proper operating condition, and in good repair. <br /> Used refrigeration must be capabte of holding at a temperature of 41°f or belov+. <br /> '15. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food <br /> preparation counters and tabies. A 15-inch high backsplash of plastic laminate, fiberglass-reinforced <br /> plastic or equal is acceptabie. A backsplash higher than 16 inches is reauired on the wall behind counter <br /> top equipment taller than 16 inches. Wall protection behind mop sinks must cover the entire splash <br /> zone. Plastic coated hardboard is not acceptable. <br /> 16. All floors in the kitchen, food preparation, food service, food storaqe, and dis`�washing areas must be <br /> surfaced v�ilh a durable, nonabsorbent, easily cleanable m2teriai. Expansion joii�ts, seams, saw cuts and <br /> the like in concrete iloors in all areas, including customer seating areas, must be falled and sealed so as <br /> to provide a smooth and cleanable sur�ace. <br /> 17. The ceiiing above the food preparation arzas must be non-perforated, nonabsorbznt, smooth and easily <br /> cleanable. <br /> 18. Cabinet shelving must be nonabsorbant, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 19. All light fixtures in food preparation and slorage areas must be provided with cov�rs and shatterproof <br /> bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. <br /> 20. Plumbing must meet state and local codes. <br /> 21. It cannot be determined from the floor plan or informalion submitted whether or not a chemical <br /> dispensing system will be instalied at the rr.�p sink. Please note that the use of screw-on type 'wye' <br /> adaptors at the mop sink faucet for use with chemical dispensing systems is prohibited. Additionaily <br /> chemical dispensers cannot be connected to the mop sink (aucet. The chemical dispenser must have a <br /> separate water connection. A 'sidekick' adaptor at the mop sink faucet is acceptable. <br /> 22. The ventilation system shall be instailed and operated to meet applicable building, mechanical, and fire <br /> codes. <br /> 23. Froper and adequate sneeze protection must be provided at the front service line. The sneeze guard <br /> must comply v+ith NSF or equivalent standards. The sneeze protection must intercept the direct line <br /> between the customer s mouth and the food preparation area. On average the vertical distance from the <br /> customers mouth to the floor is 4 feet six inches to 5 feet. Additional details are included on the <br /> enclosed iniormation sheets. <br /> A preoperational inspection is required prior to operating permit issuance and approval to open <br /> for business. At the time of inspection the conslrucfion of the food service establishment must be <br /> complete and all equipment must be in place and in proper operating condition. Incomplete construction <br /> or equipment operation �,vill result in a $168.00 re-inspection fee. Contact the Food Program office a <br /> i.— <br /> :2l3 <br />