Laserfiche WebLink
DRAWING INDEX <br /> M0.01 GENERAL NOTES AND DRAWING INDEX M2.104 INPATIENT CARE UNIT - LEVEL 10 - SECTOR D - PLUMBING M4.51 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR A - HVAC M6.30 INVASIVE PROCEDURE - LEVEL 3 - FIRE PROTECTION <br /> M0.02 MECHANICAL LEGEND M2.106 INPATIENT CARE UNIT - LEVEL 10 - SECTOR F - PLUMBING M4.52 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR B - HVAC M6.40 MECHANICAL - LEVEL 4 - FIRE PROTECTION W P„, <br /> M0.03 EQUIPMENT SCHEDULES <br /> M2.101R ROOF LEVEL - SECTOR A - PLUMBING M4.53 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR C - HVAC M6.50 FUTURE INPATIENT CARE UNIT - LEVEL 5 - FIRE PROTECTION U LI <br /> M0.04 EQUIPMENT SCHEDULES M2.102R ROOF LEVEL - SECTOR B - PLUMBING M4.54 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR D - HVAC M6.60 INPATIENT CARE UNIT - LEVEL 6 - FIRE PROTECTION <br /> M0.05 EQUIPMENT SCHEDULES M2.103R ROOF LEVEL - SECTOR C - PLUMBING M4.56 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR F - HVAC M6.70 INPATIENT CARE UNIT - LEVEL 7 - FIRE PROTECTION Z 2 <br /> M0.06 EQUIPMENT SCHEDULES M2.104R ROOF LEVEL - SECTOR D - PLUMBING M4.61 INPATIENT CARE UNIT - LEVEL 6 - SECTOR A - HVAC M6.80 INPATIENT CARE UNIT - LEVEL 8 - FIRE PROTECTION W ."°"°°` <br /> ID <br /> M0.07 EQUIPMENT SCHEDULES M2.106R ROOF LEVEL - SECTOR F - PLUMBING M4.62 INPATIENT CARE UNIT - LEVEL 6 - SECTOR B - HVAC M6.90 FUTURE INPATIENT CARE UNIT- LEVEL 9 - FIRE PROTECTION 0 ,a) <br /> M0.08 EQUIPMENT SCHEDULES M2.102MR UPPER ELEVATOR MACHINE ROOM - SECTOR B - PLUMBING M4.63 INPATIENT CARE UNIT - LEVEL 6 - SECTOR C - HVAC M6.100 INPATIENT CARE UNIT - LEVEL 10 - FIRE PROTECTION <br /> M0.09 EQUIPMENT SCHEDULES M2.102UR UPPER ROOF LEVEL - SECTOR B - PLUMBING M4.64 INPATIENT CARE UNIT - LEVEL 6 - SECTOR D - HVAC M6.100R ROOF LEVEL - FIRE PROTECTION <br /> M0.10 EQUIPMENT SCHEDULES M3.01 B SUPPORT SERVICES - LEVEL B - SECTOR A - MEDICAL GAS PIPING M4.66 INPATIENT CARE UNIT - LEVEL 6 - SECTOR F - HVAC M7.01 MECHANICAL - LEVEL 4 - ISOMETRIC (FOR REFERENCE ONLY) 0 n3 <br /> M0.11 EQUIPMENT SCHEDULES M3.02B SUPPORT SERVICES - LEVEL B - SECTOR B - MEDICAL GAS PIPING M4.71 INPATIENT CARE UNIT - LEVEL 7 - SECTOR A - HVAC M7.02 MECHANICAL - LEVEL 4 - SECTIONS (FOR REFERENCE ONLY) 0 di <br /> t <br /> t' Ce 1.1> <br /> M0.12 EQUIPMENT SCHEDULES M3.04B SUPPORT SERVICES - LEVEL B - SECTOR D - MEDICAL GAS PIPING M4.72 INPATIENT CARE UNIT - LEVEL 7 - SECTOR B - HVAC M7.03 SECTIONS <br /> M0.13 EQUIPMENT SCHEDULES M3.05B SUPPORT SERVICES - LEVEL B - SECTOR E - MEDICAL GAS PIPING M4.73 INPATIENT CARE UNIT - LEVEL 7 - SECTOR C - HVAC M7.04 TYPICAL BATHROOMS - PARTIAL PLANS - PLUMBING <br /> 4 . <br /> M0.14 EQUIPMENT SCHEDULES M3.01 EMERGENCY SERVICES - LEVEL G - SECTOR A - MEDICAL GAS PIPING M4.74 INPATIENT CARE UNIT - LEVEL 7 - SECTOR D - HVAC M7.05 STAIR 1 SECTION AND PARTIAL PLANS <br /> M0.15 EQUIPMENT SCHEDULES <br /> M3.02 EMERGENCY SERVICES - LEVEL G - SECTOR B - MEDICAL GAS PIPING M4.76 INPATIENT CARE UNIT - LEVEL 7 - SECTOR F - HVAC M7.06 STAIR 2 SECTION AND PARTIAL PLANS <br /> M0.16 EQUIPMENT SCHEDULES M3.03 EMERGENCY SERVICES - LEVEL G - SECTOR C - MEDICAL GAS PIPING M4.81 INPATIENT CARE UNIT - LEVEL 8 - SECTOR A - HVAC M7.07 STAIR 3 SECTION AND PARTIAL PLANS <br /> M0.17 EQUIPMENT SCHEDULES M3.04 EMERGENCY SERVICES - LEVEL G - SECTOR D - MEDICAL GAS PIPING M4.82 INPATIENT CARE UNIT - LEVEL 8 - SECTOR B - HVAC M7.08 STAIR 4 SECTION AND PARTIAL PLANS <br /> M0.18 EQUIPMENT SCHEDULES M3.05 EMERGENCY SERVICES - LEVEL G - SECTOR E - MEDICAL GAS PIPING M4.83 INPATIENT CARE UNIT - LEVEL 8 - SECTOR C - HVAC M7.09 STAIR 7 SECTION AND PARTIAL PLANS <br /> M0.19 EQUIPMENT SCHEDULES M3.06 EMERGENCY SERVICES - LEVEL G - SECTOR F - MEDICAL GAS PIPING M4.84 INPATIENT CARE UNIT - LEVEL 8 - SECTOR D - HVAC M7.10 EXISTING HOSPITAL - PARTIAL FIRST FLOOR PLANS - DEMOLITION EVERETT,WASHINGTON <br /> M0.20 EQUIPMENT SCHEDULES M3.12 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR B - MEDICAL GAS PIPING M4.86 INPATIENT CARE UNIT - LEVEL 8 - SECTOR F - HVAC AND MECHANICAL <br /> M8.01 DIAGRAMS - DOMESTIC HOT WATER HEATING SYSTEM AND DOMESTIC <br /> M0.21 EQUIPMENT SCHEDULES M3.13 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR C - MEDICAL GAS PIPING M4.91 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR A - HVAC WATER SERVICE GUNSO, <br /> M0.22 EQUIPMENT SCHEDULES M3.14 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR D - MEDICAL GAS PIPING M4.92 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR B - HVAC M8.02 DIAGRAMS - STEAM SYSTEM AND HOT WATER HEATING SYSTEM <,''''' <br /> 1 - SECTOR E - MEDICAL GAS PIPING M4.93 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR C - HVAC _ <br /> M0.23 EQUIPMENT SCHEDULES M3.15 DIAGNOSTIC IMAGING LEVEL M8.03 DIAGRAMS CHILLED WATER AND PROCESS CHILLED WATER PIPING �S zG F cn <br /> M0.24 EQUIPMENT SCHEDULES M3.16 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR F - MEDICAL GAS PIPING M4.94 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR D - HVAC M8.04 DIAGRAM - HEAT RECOVERY PIPING N <br /> M0.25 EQUIPMENT SCHEDULES M3.17 EXISTING HOSPITAL FLOOR PLANS - LEVELS B, 1 AND 2 - SECTOR G - MEDICAL GAS PIPING M4.96 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR F - HVAC M8.05 DIAGRAM - SYSTEM AIRFLOW �� C <br /> M0.26 EQUIPMENT SCHEDULES M3.17d EXISTING HOSPITAL FLOOR PLAN - LEVEL 1 - SECTOR G - MEDICAL GAS PIPING DEMOLITION M4.101 INPATIENT CARE UNIT - LEVEL 10 - SECTOR A - HVAC M8.06 DIAGRAM - SYSTEM AIRFLOW /7-EC��j, <br /> �/y <br /> M0.27 EQUIPMENT SCHEDULES M3.21 SURGERY - LEVEL 2 - SECTOR A - MEDICAL GAS PIPING M4.102 INPATIENT CARE UNIT - LEVEL 10 - SECTOR B - HVAC M8.07 DIAGRAM - PROCESS CHILLED WATER RISER <br /> M0.28 EQUIPMENT SCHEDULES M3.22 SURGERY - LEVEL 2 - SECTOR B - MEDICAL GAS PIPING M4.103 INPATIENT CARE UNIT - LEVEL 10 - SECTOR C - HVAC M8.08 DIAGRAM - DOMESTIC WATER RISER Architecture/Planning/Interior Design <br /> MO.29 EQUIPMENT SCHEDULES M3.23 SURGERY - LEVEL 2 - SECTOR C - MEDICAL GAS PIPING M4.104 INPATIENT CARE UNIT - LEVEL 10 - SECTOR D - HVAC Portland Seattle Los Angeles Washington DC <br /> M8.09 DIAGRAM - STEAM, CONDENSATE AND HOT WATER HEATING RISER <br /> M0.30 EQUIPMENT SCHEDULES M3.24 SURGERY - LEVEL 2 - SECTOR D - MEDICAL GAS PIPING M4.106 INPATIENT CARE UNIT - LEVEL 10 - SECTOR F - HVAC M8.10 DIAGRAM - CHILLED WATER RISER 925 Fourth Ave.,Suite 2400 <br /> /A\ M0.31 EQUIPMENT SCHEDULES M3.25 SURGERY - LEVEL 2 - SECTOR E - MEDICAL GAS PIPING M4.101R ROOF LEVEL - SECTOR A - HVAC Seattle,Washington 98104 <br /> M8.11 DIAGRAM - WASTE AND VENT PLUMBING RISER <br /> M0.32 EQUIPMENT SCHEDULES M3.26 SURGERY - LEVEL 2 - SECTOR F - MEDICAL GAS PIPING M4.102R ROOF LEVEL - SECTOR B - HVAC <br /> M8.12 DIAGRAM - WASTE AND VENT PLUMBING RISER (PH)206 623 9414 <br /> `*\ MO.33 EQUIPMENT SCHEDULES M3.27d EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - MEDICAL GAS PIPING DEMOLITION M4.103R ROOF LEVEL - SECTOR C - HVAC (FAX)206 623 7868 <br /> M8.13 DIAGRAM - WASTE AND VENT PLUMBING RISER <br /> M1.00 SITE PLAN M3.31 INVASIVE PROCEDURE - LEVEL 3 - SECTOR A - MEDICAL GAS PIPING M4.104R ROOF LEVEL - SECTOR D - HVAC M8.14 DIAGRAM - WASTE AND VENT PLUMBING RISER <br /> M2.01 F SUPPORT SERVICES - FOUNDATION - SECTOR A - PLUMBING M3.32 INVASIVE PROCEDURE - LEVEL 3 - SECTOR B - MEDICAL GAS PIPING M4.106R ROOF LEVEL - SECTOR F - HVAC M9.01 DETAILS Consultants <br /> M2.02F SUPPORT SERVICES - FOUNDATION - SECTOR B - PLUMBING M3.33 INVASIVE PROCEDURE - LEVEL 3 - SECTOR C - MEDICAL GAS PIPING M5.01 B SUPPORT SERVICES - LEVEL B - SECTOR A - HVAC PIPING M9.02 DETAILS LIFE SAFETY <br /> M2.03F SUPPORT SERVICES - FOUNDATION - SECTOR C - PLUMBING M3.34 INVASIVE PROCEDURE - LEVEL 3 - SECTOR D - MEDICAL GAS PIPING M5.02B SUPPORT SERVICES - LEVEL B - SECTOR B - HVAC PIPING ROLF JENSEN&ASSOCIATES <br /> M9.03 DETAILS 19125 North Creek Parkway Suite 120 <br /> M2.04F SUPPORT SERVICES - FOUNDATION - SECTOR D - PLUMBING M3.35 INVASIVE PROCEDURE - LEVEL 3 - SECTOR E - MEDICAL GAS PIPING M5.03B SUPPORT SERVICES - LEVEL B - SECTOR C - HVAC PIPING M9.04 DETAILS Bothell,Washington 98011 <br /> M2.05F SUPPORT SERVICES - FOUNDATION - SECTOR E - PLUMBING M3.36 INVASIVE PROCEDURE - LEVEL 3 - SECTOR F - MEDICAL GAS PIPING M5.04B SUPPORT SERVICES - LEVEL B - SECTOR D - HVAC PIPING M9.05 DETAILS CIVIL ENGINEER <br /> M2.06F SUPPORT SERVICES - FOUNDATION - SECTOR F - PLUMBING M3.41 MECHANICAL - LEVEL 4 - SECTOR A - MEDICAL GAS PIPING M5.05B SUPPORT SERVICES - LEVEL B - SECTOR E - HVAC PIPING M9.06 DETAILS - AIR HANDLERS Magnusson Klemencic Associates <br /> M2.01B SUPPORT SERVICES - LEVEL B - SECTOR A - PLUMBING M3.42 MECHANICAL - LEVEL 4 - SECTOR B - MEDICAL GAS PIPING M5.06B SUPPORT SERVICES - LEVEL B - SECTOR F - HVAC PIPING 1301 Fifth Avenue,Suite 3200 <br /> M9.07 DETAILS - AIR HANDLERS Seattle,Washington 98101-2699 <br /> M2.02B SUPPORT SERVICES - LEVEL B - SECTOR B - PLUMBING M3.43 MECHANICAL - LEVEL 4 - SECTOR C - MEDICAL GAS PIPING M5.01 EMERGENCY SERVICES - LEVEL G - SECTOR A - HVAC PIPING M9.08 DETAILS - AIR HANDLERS <br /> M2.03B SUPPORT SERVICES - LEVEL B - SECTOR C - PLUMBING M3.51 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR A - MEDICAL GAS PIPING M5.02 EMERGENCY SERVICES - LEVEL G - SECTOR B - HVAC PIPING LANDSCAPE ARCHITECT <br /> M10.01 DDC CONTROL DIAGRAMS Site Workshop <br /> M2.04B SUPPORT SERVICES - LEVEL B - SECTOR D - PLUMBING M3.52 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR B - MEDICAL GAS PIPING M5.03 EMERGENCY SERVICES - LEVEL G - SECTOR C - HVAC PIPING M10.02 DDC CONTROL DIAGRAMS 927 Post Alley <br /> M2.05B SUPPORT SERVICES - LEVEL B - SECTOR E - PLUMBING M3.53 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR C - MEDICAL GAS PIPING M5.04 EMERGENCY SERVICES - LEVEL G - SECTOR D - HVAC PIPING Seattle,Washington 98101 <br /> M10.03 DDC POINTS LIST <br /> M2.06B SUPPORT SERVICES - LEVEL B - SECTOR F - PLUMBING M3.61 INPATIENT CARE UNIT - LEVEL 6 - SECTOR A - MEDICAL GAS PIPING M5.05 EMERGENCY SERVICES - LEVEL G - SECTOR E - HVAC PIPING M10.04 DDC POINTS LIST STRUCTURAL ENGINEER <br /> M2.07B SUPPORT SERVICES - LEVEL B - SECTOR H - PLUMBING M3.62 INPATIENT CARE UNIT - LEVEL 6 - SECTOR B - MEDICAL GAS PIPING M5.06 EMERGENCY SERVICES - LEVEL G - SECTOR F - HVAC PIPING M10.05 DDC SEQUENCE OF OPERATION (AIR-SIDE) Magnusson Klemencic Associates <br /> 1301 Fifth Avenue,Suite 3200 <br /> M2.01 EMERGENCY SERVICES - LEVEL G - SECTOR A - PLUMBING M3.63 INPATIENT CARE UNIT - LEVEL 6 - SECTOR C - MEDICAL GAS PIPING M5.11 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR A - HVAC PIPING 410.6 D.0 Eo E CE OF OPERATION (WET-SIDE) Seattle,Washington 98101-2699 <br /> M2.02 EMERGENCY SERVICES - LEVEL G - SECTOR B - PLUMBING M3.64 INPATIENT CARE UNIT - LEVEL 6 - SECTOR D - MEDICAL GAS PIPING M5.12 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR B - HVAC PIPING 5 <br /> M10.07 SPECIFICATIONS MECHANICAL ENGINEER <br /> M2.03 EMERGENCY SERVICES - LEVEL G - SECTOR C - PLUMBING M3.66 INPATIENT CARE UNIT - LEVEL 6 - SECTOR F - MEDICAL GAS PIPING M5.13 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR C - HVAC PIPING <br /> CDi Engineers <br /> SERVICES LEVEL G - SECTOR D - PLUMBING M3.71 . <br /> M2.04 EMERGENCY - INPATIENT CARE UNIT - LEVEL 7 - SECTOR A - MEDICAL GAS PIPING M514 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR D - HVAC PIPING 19203 36th Ave.W,Suite 200 <br /> ;, Lynnwood,Washington 98036 <br /> h� <br /> - M2.05 EMERGENCY SERVICES - LEVEL G - SECTOR E - PLUMBING M3.72 INPATIENT CARE UNIT - LEVEL 7 - SECTOR B - MEDICAL GAS PIPING M5.15 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR E - HVAC PIPING <br /> , M2.06 EMERGENCY SERVICES - LEVEL G - SECTOR F - PLUMBING M3.73 INPATIENT CARE UNIT - LEVEL 7 - SECTOR C - MEDICAL GAS PIPING M5.16 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR F - HVAC PIPING ELECTRICAL ENGINEER <br /> SPARLING- SECTOR A - HVAC PIPING 2 <br /> M2.11 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR A - PLUMBING M3.74 INPATIENT CARE UNIT - LEVEL 7 - SECTOR D - MEDICAL GAS PIPING M5.21 SURGERY - LEVEL 720 Olive Way,Suite 1400 <br /> M2.12 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR B - PLUMBING M3.76 INPATIENT CARE UNIT - LEVEL 7 - SECTOR F - MEDICAL GAS PIPING M5.22 SURGERY - LEVEL 2 - SECTOR B - HVAC PIPING Seattle,Washington 98101-1853 <br /> M2.13 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR C - PLUMBING M3.81 INPATIENT CARE UNIT - LEVEL 8 - SECTOR A - MEDICAL GAS PIPING M5.23 SURGERY - LEVEL 2 - SECTOR C - HVAC PIPING GENERAL CONTRACTOR <br /> M2.14 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR D - PLUMBING M3.82 INPATIENT CARE UNIT - LEVEL 8 - SECTOR B - MEDICAL GAS PIPING M5.24 SURGERY - LEVEL 2 - SECTOR D - HVAC PIPING M.A.Mortenson Company <br /> 14719 N.E.29th Place <br /> M2.15 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR E - PLUMBING M3.83 INPATIENT CARE UNIT - LEVEL 8 - SECTOR C - MEDICAL GAS PIPING M5.25 SURGERY - LEVEL 2 - SECTOR E - HVAC PIPING Bellevue,Washington 98007 <br /> M2.16 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR F - PLUMBING M3.84 INPATIENT CARE UNIT - LEVEL 8 - SECTOR D - MEDICAL GAS PIPING M5.26 SURGERY - LEVEL 2 - SECTOR F - HVAC PIPING <br /> M2.17 EXISTING HOSPITAL FLOOR PLAN - LEVEL 1 - SECTOR G - PLUMBING M3.86 INPATIENT CARE UNIT - LEVEL 8 - SECTOR F - MEDICAL GAS PIPING M5.27 EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - HVAC PIPING <br /> Revisions <br /> M2.17d EXISTING HOSPITAL FLOOR PLAN - LEVEL 1 - SECTOR G - PLUMBING DEMOLITION M3.91 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR A - MEDICAL GAS PIPING M5.27d EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - HVAC PIPING DEMOLITION <br /> M2.21 SURGERY - LEVEL 2 - SECTOR A - PLUMBING M3.92 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR B - MEDICAL GAS PIPING M5.31 INVASIVE PROCEDURE - LEVEL 3 - SECTOR A - HVAC PIPING <br /> M2.22 SURGERY - LEVEL 2 - SECTOR B - PLUMBING M3.93 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR C - MEDICAL GAS PIPING M5.32 INVASIVE PROCEDURE - LEVEL 3 - SECTOR B - HVAC PIPING DOCUMENT RELEASE 09 11/03/08 <br /> M2.23 SURGERY - LEVEL 2 - SECTOR C - PLUMBING M3.101 INPATIENT CARE UNIT - LEVEL 10 - SECTOR A - MEDICAL GAS PIPING M5.33 INVASIVE PROCEDURE - LEVEL 3 - SECTOR C - HVAC PIPING DOCUMENT RELEASE 11 02/09/09 <br /> M2.24 SURGERY - LEVEL 2 - SECTOR D - PLUMBING M3.102 INPATIENT CARE UNIT - LEVEL 10 - SECTOR B - MEDICAL GAS PIPING M5.34 INVASIVE PROCEDURE - LEVEL 3 - SECTOR D - HVAC PIPING DOCUMENT RELEASE 13 03/09/09 <br /> M2.25 SURGERY - LEVEL 2 - SECTOR E - PLUMBING M3.103 INPATIENT CARE UNIT - LEVEL 10 - SECTOR C - MEDICAL GAS PIPING M5.35 INVASIVE PROCEDURE - LEVEL 3 - SECTOR E - HVAC PIPING A WORK CHANGE PROPOSAL 025.1 12/18/09 <br /> M2.26 SURGERY - LEVEL 2 - SECTOR F - PLUMBING M3.104 INPATIENT CARE UNIT - LEVEL 10 - SECTOR D - MEDICAL GAS PIPING M5.36 INVASIVE PROCEDURE - LEVEL 3 - SECTOR F - HVAC PIPING GENERAL NOTES <br /> WORK CHANGE PROPOSAL 025.2 1/04/10 <br /> M2.27 EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - PLUMBING M3.106 INPATIENT CARE UNIT - LEVEL 10 - SECTOR F - MEDICAL GAS PIPING M5.41 MECHANICAL - LEVEL 4 - SECTOR A - HVAC PIPING A WORK CHANGE PROPOSAL 025.3 1/11/10 <br /> M2.27d EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - PLUMBING DEMOLITION M4.01 B SUPPORT SERVICES - LEVEL B - SECTOR A - HVAC M5.42 MECHANICAL LEVEL 4 SECTOR B HVAC PIPING <br /> M2.31 INVASIVE PROCEDURE - LEVEL 3 - SECTOR A - PLUMBING M4.02B SUPPORT SERVICES - LEVEL B - SECTOR B - HVAC M5.43 MECHANICAL - LEVEL 4 - SECTOR C - HVAC PIPING <br /> DIAGRAMS, AND AS DESCRIBED IN SPECIFICATIONS. A WORK CHANGE PROPOSAL 025.4 2/01/10 <br /> M2.32 INVASIVE PROCEDURE - LEVEL 3 - SECTOR B - PLUMBING M4.03B SUPPORT SERVICES - LEVEL B - SECTOR C - HVAC M5.44 MECHANICAL - LEVEL 4 - SECTOR D - HVAC PIPING 2. INSTALL ALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE ABOVE. A WORK CHANGE PROPOSAL 145 06/02/14 <br /> M2.33 INVASIVE PROCEDURE - LEVEL 3 - SECTOR C - PLUMBING M4.048 SUPPORT SERVICES - LEVEL B - SECTOR D - HVAC M5.45 MECHANICAL - LEVEL 4 - SECTOR E - HVAC PIPING 3. THE MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE AND DO NOT ATTEMPT <br /> TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL AND STRUCTURAL <br /> M2.34 INVASIVE PROCEDURE - LEVEL 3 - SECTOR D - PLUMBING M4.05B SUPPORT SERVICES - LEVEL B - SECTOR E - HVAC M5.46 MECHANICAL - LEVEL 4 - SECTOR F - HVAC PIPING DRAWINGS FOR CONSTRUCTION DETAILS. <br /> M2.35 INVASIVE PROCEDURE - LEVEL 3 - SECTOR E - PLUMBING M4.06B SUPPORT SERVICES - LEVEL B - SECTOR F - HVAC M5.51 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR A - HVAC PIPING 4. ITEMS NOTED "TYPICAL" OR "TYP" ON ANY SHEET APPLY TO THAT PARTICULAR SHEET. <br /> M2.36 INVASIVE PROCEDURE - LEVEL 3 - SECTOR F - PLUMBING M4.01 EMERGENCY SERVICES - LEVEL G - SECTOR A - HVAC M5.52 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR B - HVAC PIPING 5. COORDINATE WITH SPECIFICATIONS. IN CASE OF CONFLICT BETWEEN SPECIFI- <br /> M2.41 MECHANICAL - LEVEL 4 - SECTOR A - PLUMBING M4.02 EMERGENCY SERVICES - LEVEL G - SECTOR B - HVAC M5.53 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR C - HVAC PIPING CATIONS AND DRAWINGS THE MORE STRINGENT SHALL APPLY. <br /> M2.42 MECHANICAL - LEVEL 4 - SECTOR B - PLUMBING M4.03 EMERGENCY SERVICES - LEVEL G - SECTOR C - HVAC M5.56 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR F - HVAC PIPING 6. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES <br /> M2.43 MECHANICAL - LEVEL 4 - SECTOR C - PLUMBING M4.04 EMERGENCY SERVICES - LEVEL G - SECTOR D - HVAC M5.61 INPATIENT CARE UNIT - LEVEL 6 - SECTOR A - HVAC PIPING FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS CLOSEOUT PRINTING 04/01/12 <br /> M2.44 MECHANICAL - LEVEL 4 - SECTOR D - PLUMBING M4.05 EMERGENCY SERVICES - LEVEL G - SECTOR E - HVAC M5.62 INPATIENT CARE UNIT - LEVEL 6 - SECTOR B - HVAC PIPING REQUIRED. <br /> M2.45 MECHANICAL - LEVEL 4 - SECTOR E - PLUMBING M4.06 EMERGENCY SERVICES - LEVEL G - SECTOR F - HVAC M5.63 INPATIENT CARE UNIT - LEVEL 6 - SECTOR C - HVAC PIPING 7. COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES TO INSURE <br /> PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF THIS Drawing Title <br /> M2.46 MECHANICAL - LEVEL 4 - SECTOR F - PLUMBING M4.11 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR A - HVAC M5.64 INPATIENT CARE UNIT - LEVEL 6 - SECTOR D - HVAC PIPING CONTRACTOR. PROVIDE COORDINATED SHOP DRAWINGS PRIOR TO FABRICATION <br /> M2.51 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR A - PLUMBING M4.12 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR B - HVAC M5.66 INPATIENT CARE UNIT - LEVEL 6 - SECTOR F - HVAC PIPING AND INSTALLATION. GENERAL NOTES AND <br /> M2.52 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR B - PLUMBING M4.13 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR C - HVAC M5.71 INPATIENT CARE UNIT - LEVEL 7 - SECTOR A - HVAC PIPING 8. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING DRAWING INDEX <br /> CONSTRUCTION. <br /> M2.53 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR C - PLUMBING M4.14 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR D - HVAC M5.72 INPATIENT CARE UNIT - LEVEL 7 - SECTOR B - HVAC PIPING <br /> M2.54 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR D - PLUMBING M4.15 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR E - HVAC M5.73 INPATIENT CARE UNIT - LEVEL 7 - SECTOR C - HVAC PIPING 9. VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY WORK ON AN EXISTING <br /> MECHANICAL SYSTEM. <br /> M2.55 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR E - PLUMBING M4.16 DIAGNOSTIC IMAGING - LEVEL 1 - SECTOR F - HVAC M5.74 INPATIENT CARE UNIT - LEVEL 7 - SECTOR D - HVAC PIPING <br /> 10. ALL DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DIMENSION <br /> M2.56 FUTURE INPATIENT CARE UNIT - LEVEL 5 - SECTOR F - PLUMBING M4.17 EXISTING HOSPITAL FLOOR PLAN - LEVEL 1 - SECTOR G - HVAC M5.76 INPATIENT CARE UNIT - LEVEL 7 - SECTOR F - HVAC PIPING FOR INSULATION TO OBTAIN "TOTAL" DUCT SIZE. <br /> M2.61 INPATIENT CARE UNIT - LEVEL 6 - SECTOR A - PLUMBING M4.17d EXISTING HOSPITAL FLOOR PLAN - LEVEL 1 - SECTOR G - HVAC DEMOLITION M5.81 INPATIENT CARE UNIT - LEVEL 8 - SECTOR A - HVAC PIPING 11. INSTALL COMBINATION FIRE/SMOKE DAMPERS AT ALL LOCATIONS WHERE DUCTS <br /> M2.62 INPATIENT CARE UNIT - LEVEL 6 - SECTOR B - PLUMBING M4.21 SURGERY - LEVEL 2 - SECTOR A - HVAC M5.82 INPATIENT CARE UNIT - LEVEL 8 - SECTOR B - HVAC PIPING PENETRATE FIRE RATED WALLS. DAMPER FIRE RATING SHALL BE 1-1/2 HOUR <br /> - - - PLUMBINGSURGERY - LEVEL 2 - SECTOR B - HVAC M5.83 INPATIENT CARE UNIT - LEVEL 8 - SECTOR C - HVAC PIPING UNLESS NOTED OTHERWISE. COORDINATE DAMPER ACCESS WITH GENERAL ` " "' <br /> M2.63 INPATIENT CARE UNIT LEVEL 6 SECTOR C M4.22 s <br /> CONTRACTOR AND ELECTRICAL CONNECTIONS WITH ELECTRICAL CONTRACTOR. * �` r <br /> M2.64 INPATIENT CARE UNIT - LEVEL 6 - SECTOR D - PLUMBING M4.23 SURGERY - LEVEL 2 - SECTOR C - HVAC M5.84 INPATIENT CARE UNIT - LEVEL 8 - SECTOR D - HVAC PIPING A FOR ' ,,, '" <br /> 12. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS ," <br /> M2.66 INPATIENT CARE UNIT - LEVEL 6 - SECTOR F - PLUMBING M4.24 SURGERY - LEVEL 2 - SECTOR D - HVAC M5.86 INPATIENT CARE UNIT -'LEVEL 8 - SECTOR F - HVAC PIPING EXACT LOCATION OF ALL DIFFUSERS AND GRILLES. r441.4 et,,,,4 <br /> ' <br /> M2.71 INPATIENT CARE UNIT - LEVEL 7 - SECTOR A - PLUMBING M4.25 SURGERY - LEVEL 2 - SECTOR E - HVAC M5.91 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR A - HVAC PIPING 13. MAXIMUM FLEXIBLE DUCT LENGTH SHALL BE 6'-0" WITH 0.5 x DUCT DIAMETER 0,41- <br /> `' '` :%`. ' <br /> M2.72 INPATIENT CARE UNIT - LEVEL 7 - SECTOR B - PLUMBING M4.26 SURGERY - LEVEL 2 - SECTOR F - HVAC M5.93 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR C - HVAC PIPING OFFSET, UNLESS NOTED OTHERWISE. °©N'L,, <br /> M2.73 INPATIENT CARE UNIT - LEVEL 7 - SECTOR C - PLUMBING M4.27 EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - HVAC M5.96 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR F - HVAC PIPING 14. PROVIDE CONCEALED DAMPER REGULATORS FOR ALL VOLUME DAMPERS OVER <br /> M2.74 INPATIENT CARE UNIT - LEVEL 7 - SECTOR D - PLUMBING M4.27d EXISTING HOSPITAL FLOOR PLAN - LEVEL 2 - SECTOR G - HVAC DEMOLITION M5.101 INPATIENT CARE UNIT - LEVEL 10 - SECTOR A - HVAC PIPING INACCESSIBLE CEILINGS AND SOFFITS. REFER TO ARCHITECTURAL DRAWINGS <br /> FOR CEILING TYPES. COORDINATE JACK LOCATION WITH ARCHITECT.. <br /> M2.76 INPATIENT CARE UNIT - LEVEL 7 - SECTOR F - PLUMBING M4.31 INVASIVE PROCEDURE - LEVEL 3 - SECTOR A - HVAC M5.102 INPATIENT CARE UNIT - LEVEL 10 - SECTOR B - HVAC PIPING Date: NOVEMBER 03,2008 <br /> 15. PROVIDE TRANSITIONS AS REQUIRED TO CONNECT DUCTWORK TO AIR TERMINAL <br /> M2.81 INPATIENT CARE UNIT - LEVEL 8 - SECTOR A - PLUMBING M4.32 INVASIVE PROCEDURE - LEVEL 3 - SECTOR B - HVAC M5.103 INPATIENT CARE UNIT - LEVEL 10 - SECTOR C - HVAC PIPING UNITS, FANS AND OTHER MECHANICAL EQUIPMENT. Job No: S80613.01 <br /> M2.82 INPATIENT CARE UNIT - LEVEL 8 - SECTOR B - PLUMBING M4.33 INVASIVE PROCEDURE - LEVEL 3 - SECTOR C - HVAC M5.104 INPATIENT CARE UNIT - LEVEL 10 - SECTOR D - HVAC PIPING 16. PROVIDE DIFFUSER AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL Drawn By: CDi <br /> M2.83 INPATIENT CARE UNIT - LEVEL 8 - SECTOR C - PLUMBING M4.34 INVASIVE PROCEDURE - LEVEL 3 - SECTOR D - HVAC M5.106 INPATIENT CARE UNIT - LEVEL 10 - SECTOR F - HVAC PIPING CEILING TYPE. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR Checked By: FJ <br /> M2.84 INPATIENT CARE UNIT - LEVEL 8 - SECTOR D - PLUMBING M4.35 INVASIVE PROCEDURE - LEVEL 3 - SECTOR E - HVAC M5.101 R ROOF LEVEL - SECTOR A - HVAC PIPING CEILING TYPE. <br /> M2.86 INPATIENT CARE UNIT - LEVEL 8 - SECTOR F - PLUMBING M4.36 INVASIVE PROCEDURE - LEVEL 3 - SECTOR F - HVAC M5.102R ROOF LEVEL - SECTOR B - HVAC PIPING 17. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM Drawing No. <br /> TEMPERATURE SENSORS WITH ARCHITECT PRIOR TO INSTALLATION. <br /> M2.91 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR A - PLUMBING M4.37 EXISTING HOSPITAL FLOOR PLAN - LEVEL 3 - NEW BRIDGE - MECHANICAL M5.103R ROOF LEVEL - SECTOR C - HVAC PIPING <br /> 18. PROVIDE A VOLUME DAMPER FOR EACH SUPPLY, RETURN AND EXHAUST <br /> M2.92 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR B - PLUMBING M4.41 MECHANICAL - LEVEL 4 - SECTOR A - HVAC M5.104R ROOF LEVEL - SECTOR D - HVAC PIPING OPENING AND IN BRANCHES WHERE THREE OR MORE OPENINGS ARE ASSOCIATED <br /> M2.93 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR C - PLUMBING M4.42 MECHANICAL - LEVEL 4 - SECTOR B - HVAC M5.106R ROOF LEVEL - SECTOR F - HVAC PIPING WITH THE BRANCH AND ELSEWHERE AS NOTED ON THE DRAWINGS OR <br /> M2.94 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR D - PLUMBING M4.42M MECHANICAL - LEVEL 4 - MEZZANINE - SECTOR B - HVAC M6.00B SUPPORT SERVICES - LEVEL B - FIRE PROTECTION SPECIFICATIONS. <br /> M2.96 FUTURE INPATIENT CARE UNIT - LEVEL 9 - SECTOR F - PLUMBING M4.43 MECHANICAL - LEVEL 4 - SECTOR C - HVAC M6.00 EMERGENCY SERVICES - LEVEL G - FIRE PROTECTION 19. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL PLUMBING MO.O1 <br /> FIXTURES WITH CASEWORK AND ARCHITECTURAL DRAWINGS. <br /> M2.101 INPATIENT CARE UNIT - LEVEL 10 - SECTOR A - PLUMBING M4.44 MECHANICAL - LEVEL 4 - SECTOR D - HVAC M6.10 DIAGNOSTIC IMAGING - LEVEL 1 - FIRE PROTECTION <br /> 20. PROVIDE VENTS FROM ALL GAS PRESSURE REGULATORS TO A SAFE LOCATION <br /> M2.102 INPATIENT CARE UNIT - LEVEL 10 - SECTOR B - PLUMBING M4.45 MECHANICAL - LEVEL 4 - SECTOR E - HVAC M6.17 EXISTING HOSPITAL FLOOR PLANS - LEVELS 1 AND 2 - SECTOR G -FIRE PROTECTION OUTSIDE THE BUILDING. <br /> M2.103 INPATIENT CARE UNIT - LEVEL 10 - SECTOR C - PLUMBING M4.46 MECHANICAL - LEVEL 4 - SECTOR F - HVAC M6.20 SURGERY - LEVEL 2 - FIRE PROTECTION 1700 13th St-PGMC 2'Floor Surgery-B1406-017 <br />