. KITCHEN EQUIPMENT CONNECTIONSCD
<br /> MARK 2 3 5 6 8 14 15 19 21 21 26 26 31 38 38 43 43 44 47 48 60 65 66A 4-
<br /> DESCRIPTION HAND SINK HAND POT FAUCET DISH COFFEE WALK-IN ESPRESSO HAND WALK-IN DIPPERWELL WALK-IN WALK-IN ICE FREEZER WASTE BLAST FAUCET SERVICE NOT USED PREP PREP FAUCET W „,..,
<br /> W EYEWASH SINK SINK PRE RINSE WASHER MAKER COIL MAKER SINK COIL _ COIL COIL MACHINE COIL SINK CHILL FRZR SINK TABLE TABLE
<br /> EQUIPMENT BRANCH SZ: CW: IN. 1/2 1/2 - 1/2 1/2 1/2 - 1/2 1/2 - 1/2 - - 1/2 - - - 1/2 1/2 1/2 - 1/2
<br /> U U
<br /> [1, 2] BRANCH SZ: HW: IN. 1/2 1/2 - 1/2 1/2 - - - 1/2 - - - - - - - - 1/2 1/2 1/2 - 1/2
<br /> Z 76:,
<br /> DIRECT WASTE: IN 1 1/2 1 1/2 - - - - - - 1 1/2 - - - - - - - - - 3 - - -
<br /> INDIRECT WASTE: IN - - (3) 1 1/2 _ - 3/4 - 3/4 3/4 - 3/4 3/4 3/4 3/4 3/4 3/4 1 1/2 3/4 - - 1 1/2 1 1/2 -
<br /> W .--
<br /> GAS: IN. - - - - - - - - - - - - - - - - - - - - - -_
<br /> 0 .va)
<br /> LOAD: MBH - - - - - - - - - - - - - - - - - - - - -
<br /> STEAM INLET: IN. -
<br /> STEAM COND: IN. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 0 r0
<br /> STEAM: PPH
<br /> EXH AIR: IN. - - - - - - - - - - - - - - - - - - - ( ' '
<br /> - - -
<br /> EXH AIR QTY: CFM - - - - - - - - - - - - - - _ - - - -
<br /> SUPPLY AIR: IN.
<br /> SUPP AIR QTY: CFMt' a) >
<br /> - - - - - - - - - - - - - - - - - - - -
<br /> NOTES [4] [4] [4] [4] [4] [6] [4] [4] /\ [6] [4] A [6] [6] [4] [6] [4] [6] [4] A [4] [6] [6]
<br /> MARK 68 69 70 71 72 73 74 75 78 90 94 104 105 106 107 108 111 224 129 132 133
<br /> PASTA COCOA
<br /> HAND SINK REACH
<br /> N PASTA
<br /> R HAND SINK AST
<br /> PRE FAU ET PREP DISPOSER
<br /> C
<br /> DESCRIPTION HAND SINK TILT TILT FLOOR TILT TILT KETTLE CONVECTION COMBINATION HAND SINK NOT USED
<br /> 4
<br /> ::::..::........:::...
<br /> W EYEWASH KETTLE KETTLE TROUGH SKILLET SKILLET STAND OVEN _ OVEN W EYEWASH SINK RINSE W EYEWASH COOKER DISPENSER W EYEWASH REFRIG COOKER
<br /> EQUIPMENT BRANCH SZ: CW: IN. 1/2 1/2 1/2 - 1/2 1/2 - - (2) 3/4 1/2 1/2 - 1/2 1/2 1/2 1/2 1/2 1/2 - 1/2
<br /> [1, 2] BRANCH SZ: HW: IN. 1/2 1/2 1/2 - 1/2 1/2 - - - 1/2 1/2 - - 1/2 1/2 - - 1/2 - -
<br /> DIRECT WASTE: IN 1 1/2 - - 4 - - - - - 1 1/2 - - 2 - 1 1/2 - - 1 1/2 - -
<br /> INDIRECT WASTE: IN - - 1 1/4 - - - 1 1/4 - (2) 2 - - 1 1/2 - - - 1 1/4 - - 3/4 1 1/4 EVERETT,WASHINGTON
<br /> GAS: IN. - 3/4 3/4 A - 3/4 3/4 - (2) 3/4 (2) 1/2 - - - - - - 3/4 - - - 3/4
<br /> LOAD: MBH - 100 52 - 34 34 - _ (2) AT 50 95 - - - - - - 80 - - - 80 ,GU NS(l�
<br /> STEAM INLET: IN. - - - - - - - - - - - - - - - - - - <,,S1-:
<br /> STEAM COND: IN. - - - - - - - - - - - - - - - - - y
<br /> STEAM: PPH - - - - - - - - - - - - - - - - - - - -
<br /> -t:,LG r f
<br /> EXH AIR: IN. - - - - - - - - - - - - - - -
<br /> EXH AIR QTY: CFM �� �C
<br /> SUPPLY AIR: IN. - _ _ _ _ _ _ _ _ _ _ _ - - - - - - - �yJTEC�S
<br /> SUPP AIR QTY: CFM
<br /> NOTES [9] [6, 9] A [8] [9] [9] [6] [9] [6, 9] [6] [6, 9] [6] [6, 9]
<br /> MARK 134 137 213 163 177 187 194 210 216 217 219 220 221 222 225 226 227 228 230 231 238 240 241 Architecture/Planning/Interior Design
<br /> DESCRIPTION COUNTER GAS COCOA HAND FILLER HAND SINK FILLER HAND SINK BEVERAGE COFFEE SODA ICE CARBONAT. JUICE JUICE SODA ICE CARBONAT. COFFEE BEVERAGE ICE ICE WATER Portland Seattle Los Angeles Washington DC
<br /> HOT PLATE BROILER DISPENSER SINK FAUCET W EYEWASH _ FAUCET W EYEWASH TABLE MAKER DISPENSER MAKER DISPENSER DISPENSER DISPENSER MAKER MAKER TABLE MAKER BIN FILTER 925 Fourth Ave.,Suite 2400
<br /> EQUIPMENT BRANCH SZ: CW: IN. - - 1/2 1/2 - 1/2 - 1/2 - 1/2 - 1/2 1/2 1/2 1/2 - 1/2 1/2 1/2 - 1/2 - 1/2 Seattle,Washington 98104
<br /> [1, 2] BRANCH SZ: HW: IN. - - - 1/2 1/2 1/2 1/2 1/2 - - - - - - - - - - - - - -
<br /> DIRECT WASTE: IN - - - 1 1/2 - 1 1/2 - 11/2 - - - - - - - - - - - - - -
<br /> - - - - - - 1 - 3 4 3 4 3 4 - - 3 4 3 4 3/4 - 1 3/4 3/4 _ PH 206 623 9414
<br /> INDIRECT WASTE: IN 1 1 / / / / /
<br /> FAX)206 623 7868
<br /> GAS: IN. 3/4 3/4 - - - - - - - - - - - - - - - - - - - - -
<br /> LOAD: MBH 120 90 - - - - - - - - - - - - - - - - - - - - -
<br /> Consultants
<br /> STEAM INLET: IN.
<br /> STEAM COND: IN. - - - - - - - - - - - - - - - - - - - - - - - LIFE SAFETY
<br /> STEAM: PPH - - - - - - - - - - - - - - - - - - - - - - - ROLF JENSEN&ASSOCIATES
<br /> 19125 North Creek Parkway Suite 120
<br /> EXH AIR: IN. - - - - - - - - - - - - - - - - - - - - Bothell,Washington 98011
<br /> EXH AIR QTY: CFM - - - - - - - - - - - - - - - - - - - - -
<br /> SUPPLY AIR: IN. - - - - - - - - - - - - - - - - -
<br /> - - - - - - CIVIL ENGINEER
<br /> SUPP AIR QTY: CFM - - - - - - - - - - - - - - - - - - -
<br /> - - Magnusson Klemencic Associates
<br /> NOTES [9] [9] [6] [6] [61A [6] [6] [6] [6] [6] [6] [6] [6] [6] 1301 Fifth Avenue,Suite 3200
<br /> MARK 242 249 250 251 252 253 256 258 261 �'T\ 262 263 268 269 270 274 239 285 289 291 292 Seattle,Washington 98101-2699
<br /> DESCRIPTION FLOOR FLOOR HAND SINK FLOOR STEAM MOP HOSE FLOOR DISH DISH DISH 3 COMP PRE FAUCET HAND SINK REMOTE SOAK HOSE SOILED TROUGH LANDSCAPE ARCHITECT
<br /> TROUGH TROUGH W EYEWASH TROUGH WASHER SINK REEL TROUGH WASHER WASHER WASHER SINK RINSE W EYEWASH CONDENSER SINK REEL TABLE VEYOR Site Workshop
<br /> EQUIPMENT BRANCH SZ: CW: IN. - - 1/2 - - 1/2 1/2 - (2) 1/2 - - - 1/2 (2) 1/2 1/2 - - 1/2 1/2 1/2 927 Post Alley
<br /> [1, 2] BRANCH SZ: HW: IN. - - 1/2 - 1/2 1/2 1/2 - (2) 3/4 - - - 1/2 (2) 1/2 1/2 - - 1/2 - 1/2 Seattle,Washington 98101
<br /> DIRECT WASTE: IN 4 4 1 1/2 _ 4 - 3 - 4 - - - - - 1 1/2 - - - - 2
<br /> INDIRECT WASTE: IN - - - - - - - - 2 - - (3) 1 1/2 - - _ - _ _ 3/4 1 1/2 - - - STRUCTURAL ENGINEER
<br /> _ Magnusson Klemencic Associates
<br /> GAS: IN. - - - - - - - - - - - - - - - - 1301 Fifth Avenue,Suite 3200
<br /> LOAD: MBH - - - - - - - - - - - - - - - -
<br /> - - - - Seattle,Washington 98101-2699
<br /> STEAM INLET: IN. - - - - - - - - 2 AND 3/4 - - - - - - - - - - -
<br /> STEAM COND: IN. - - - - - - - - 1 AND 1/2 - - - - - - - - - - -
<br /> MECHANICAL ENGINEER
<br /> STEAM: PPH - - - - - - - - 400 - - - - - - - -
<br /> - - - CDi Engineers
<br /> 3 36th Ave.
<br /> e 200
<br /> EXH AIR: IN. - - - - - - - - - [5] 16 - - - - - - - - - LnOnwood,Washi gt on
<br /> t98036
<br /> Y
<br /> EXH AIR QTY: CFM - - - - - - - - - - 1,000 - - - - - - - - - -
<br /> SUPPLY AIR: IN. - - - - - - - - - - - - - - - -
<br /> - - - - ELECTRICAL ENGINEER
<br /> SUPP AIR QTY: CFM
<br /> _ _ _ _ _ _ _ _ SPARLING
<br /> 8 3, 5-7, 10 ,1 1] [5] [7] [7] [6] 2 TYP [6] 2 TYP 720 Olive Way,Suite 1400
<br /> NOTES [8] [8] [8] [ ] [ Seattle,Washington 98101-1853
<br /> NOTES:
<br /> 1. EQUIPMENT FURNISHED BY KITCHEN CONTRACTOR. 5. REFER TO KITCHEN EQUIPMENT DRAWINGS. 9. PROVIDE GAS COCK AND UNION SHUT-OFF VALVE. INSTALL GAS QUICK DISCONNECT KIT. GENERAL CONTRACTOR
<br /> 2. SEE KITCHEN DRAWINGS FOR ROUGH-IN LOCATIONS AND ELEVATIONS. 6. PIPE INDIRECT WASTE TO FLOOR SINK WITH AIR GAP. 10. PIPE 3/4" HW RELIEF VALVE TO FLOOR SINK. MEDICAL AND LAB GAS OUTLETS M.A.Mortensen Company
<br /> 3. INSTALL AND CONNECT EQUIPMENT SUPPLIED STEAM TRAPS. PROVIDE 1/2" 7. 140 DEGREE HOT WATER USED. 11. INSTALL FOUR 3/4" CONDENSATE BUCKET TRAPS PROVIDED WITH DISHWASHER. PIPE TO MARK 02 MA MV V-SLIDES WAGD N2 N2[10] N20 CO2 L02 LA LV REMARKS 14719 N.E.29th Place
<br /> CW TO AFTER DRAIN COOLER AND PIPE DRAIN TO FLOOR SINK AS REQUIRED. 8. PROVIDED BY KITCHEN CONTRACTOR, INSTALLED BY PLUMBING CONTRACTOR. CP-4. A 2 2 2 2 WALL Bellevue,Washington 98007
<br /> 4. EQUIPMENT LOCATED IN THE ESPRESSO AREA. SEE A2.11 AND M2.11. B 2 2 4 4 WALL
<br /> C 2 2 4 - BOOM
<br /> Revisions
<br /> EQUIPMENT CONNECTION AA 0 0 0 D 1 1 1 1 WALL E 1 1 1 WALL
<br /> MARK 3693-003 3704-009 3753-024 3835-002 3990-001 4386-001 4561-015 4671-002 4673-017 4682-021 4695-006 4817-001 4916-005 4942-062 4947-003 F 2 - 1 1 WALL DOCUMENT RELEASE 09 11/03/08
<br /> DESCRIPTION DIALYSIS DISH CLOTHES STEAM MULTI- ENDOSCOPE ULTRASONIC CART WASHER WASHER WATER ICE ICE REFRIG DISPENSER G 2 - 2 2 WALL
<br /> UNIT WASHER DRYER GUN LOADER STERILIZER CLEANER WASHER CLOTHES DISINFECT PURIFIER MACHINE MACHINE JUICE H A 2 2 3 3 + WALL DOCUMENT RELEASE 11 02/09/09
<br /> BRANCH SIZE/ CW: IN - - -- 3/4 1/2 - - 2/(1) 3/4/(1/2) 1/2 3/4 1/2 1/2 1/2 1/2 J 4 4 8 - COLUMN DOCUMENT RELEASE 13 03/09/09
<br /> (CONN SIZE) HW: IN - 1/2 - - - 1/2 1/2 2/(1) 3/4/(1/2) 1/2 - - - - - J1 2 2 4 - COLUMN
<br /> DI: IN 1/2 - - - - - - - - - - - - - - K 2 1 2 2 WALL n DOCUMENT RELEASE 21 09/14/09
<br /> RO: IN - - - - - - - - - - - - - - - L 2 2 2 - 1 1 1 ANESTH BOOM A DOCUMENT RELEASE 22 09/28/09
<br /> DIRECT WASTE: IN - - - - - 2 - - - - - - - - - M 1 1 / \ 2 - 1 1 1 EQUIP BOOM
<br /> INDIRECT DRAIN: IN 3/4 1 1/ 3 2 2 ( ) 3/
<br /> - - - - 4 2 4 3/4 3 4 - - N 1 1 4 - 1 2 PERFUSION BOOM A WORK CHANGE PROPOSAL 15 11/09/09
<br /> / /
<br /> STEAM: IN - - - 3/4 - - - 2/(1 1/2) - - - - - - - P 1 1 1 1 WALL A WORK CHANGE PROPOSAL 23 12/15/09
<br /> STEAM: PPH - - - 65 - - - 1400 - - - - - - - Q 2 2 WALL
<br /> R 1 WALL A WORK CHANGE PROPOSAL 27.6 03/08/09
<br /> CONDENSATE. IN 1 //\ �
<br /> CA: IN - - - - - - - 1/(1/2) - 1/2 - - - - - S 1 1 /9\ ,HOSE DROPS \ WORK CHANGE PROPOSAL 27.5 03/08/10
<br /> VAC: IN - - - - - - - - - - - - - - - T 1 1 WALL WORK CHANGE PROPOSAL 23.5 03/09/10
<br /> EXHAUST VENT: IN - - 4 - - - - - A - - - - - - U 1 1 1 WALL
<br /> A A A EXHAUST AIR: CFM - - - - - - �
<br /> - - _ - V 1 1 1 FLOOR PEDESTAL, 12 /7\ AN WORK CHANGE PROPOSAL 27.7R1 06/10/10
<br /> NOTES
<br /> 0 0 W 3 1 1 2 EQUIP BOOM /8\ /9\ RFI 2386 07/14/10
<br /> MARK 5241-044 4678-016 4678-017 5369-001 5898-006 5974-006 STERIS 11 6156-004 6480-005 6508-005 6610-003 C121658 C115318 C106207 C105648 X 4 1 1 2 EQUIP BOOM
<br /> DESCRIPTION WASHER WASHER WASHER STERILIZER COFFEE SINK CONVEYOR WATER STEAM At MORGUE NEPTUNE STEAM STEAM AIR WATER Z 2 1 ANESTH BOOM
<br /> DISINFECTOR DISINFECTOR DISINFECTOR COMPACTOR MAKER 2 COMP PURIFIER STERILIZER COOLER DOCK STERILIZER STERILIZER GUN GUN AA 4 1 1 1 ANESTH BOOM CLOSEOUT PRINTING 04/01/12
<br /> BRANCH SIZE/ CW: IN 1/(1/2) (3 1/(3) 1/2 3 1/(3) 1/2 1/2 1/2 1/(1/2) 3/4 1 - 1/2 1/(3/4) 1 - - AB 1 1 2 1 HOSE DROPS A
<br /> (CONN SIZE) HW: IN 1/(1/2) (2) 1/(2) 1/2 (2) 1/(2) 1/2 - - 1/(1/2) - - - 1/2 - - - 1/2 AC 1 1 2 1 1 EQUIP BOOMDI: IN n
<br /> NOTES: //\ I9\ 4
<br /> R0: IN 1/(1/2) 1/(1/2) 1/(1/2) - - 1/2 - - - - - _ _ _ 1. MEDICAL GAS OUTLETS AND INLETS SHALL BE FURNISHED AND INSTALLED BY PLUMBING CONTRACTOR. Drawing Title
<br /> DIRECT WASTE: IN - - - - - (2) 2 - - - _ _ _ _ _ 2. MEDICAL GAS OUTLETS AS PART OF THE HEADWALL UNIT, CEILING MOUNTED COLUMN, OR CEILING MOUNTED BOOM SHALL BE FURNISHED BY GENERAL
<br /> 1 1 3 2 3 1 1 2 2 - - 1 1 2 3 4 1 1 2 3 4 1 2 2 - _ CONTRACTOR AND INSTALLED BY PLUMBING CONTRACTOR. MULTIPLE CONNECTIONS REQUIRED SHALL BE SPLIT OFF SINGLE LINE SHOWN ON PLANS TO UNIT. EQUIPMENT SCHEDULES
<br /> INDIRECT DRAIN. IN 2 (3) 2/(3) /2( ) /( ) / / / / / /
<br /> STEAM: IN 1/(1/2) (2) 1/(2) 1/2 (2) 1/(2) 1/2 1 - - /2\ - 1/2 - - 1 1/2/(3/4) 1 1/2/(1) - _ 3. PLUMBING CONTRACTOR SHALL COORDINATE PIPE CONNECTIONS WITH SHOP DRAWINGS OF SPECIALTY EQUIPMENT.
<br /> STEAM: PPH 300 300 300 - - - - 116 - - 310 300 - -
<br /> 4. THE MINIMUM SIZE FOR HORIZONTAL MEDICAL VACUUM PIPING SHALL BE 1", MINIMUM SIZE FOR VERTICAL MEDICAL VACUUM PIPING SHALL BE 3/4" WORK CHANGE PROPOSAL 42.2 07/16/10
<br /> CONDENSATE: IN 1/2 2 1/2 2 1/2 1 1/2 4 - - - - - 1 1 - _ UNLESS NOTED OTHERWISE. A NOT USED
<br /> CA: IN 1/2 1/2 1/2 - - - 1/2 - - - - 1/2 1/2 1/2 _ 5. THE MINIMUM SIZE FOR MEDICAL AIR AND OXYGEN PIPING SHALL BE 1/2" UNLESS NOTED OTHERWISE. WORK CHANGE PROPOSAL 27.10 08/06/10
<br /> VAC: IN - - - - - - - - _ _ _ _ _ _ 6. PIPING TO OUTLETS IN ADJACENT ROOMS SHALL BE SERVED BY SINGLE PIPING RUNOUTS FROM THE HORIZONTAL BRANCH MAINS.
<br /> 7. MEDICAL GAS OUTLETS SHALL BE MOUNTED AT HEIGHTS AS SI- W/�\N ON ARCHITECTURAL INTERIOR ELEVATIONS. A WORK CHANGE PROPOSAL 87.1 R1 3/10/11
<br /> EXHAUST VENT: IN - - - - - - - - - - - - - -
<br /> EXHAUST AIR: CFM - - - - - - _ _ _ _ _ _ _ _ 8. PROVIDE QUICK CONNECT OUTLET FOR HPA. A WORK CHANGE PROPOSAL 87.1 R5 07/08/11
<br /> NOTES I [3, 7] [6] [5] [8] 9. PROVIDE PRV FOR LA IN STAINLESS STEEL WALL CABINET.
<br /> MARK 4242-006 10. NITROGEN SUPPLIED TO BOOM THRU PRESSURE REDUCING VALVE. MEDICAL AIR COMPRESSOR ,.
<br /> Q 11. PROVIDE NON-FERROUS OUTLETS IN MRI ROOMS. MARK MAC-1 (04471
<br /> 0 As,I, ,
<br /> DESCRIPTION REFRIDGE 12. COORDINATE WITH ELECTRICAL FOR OUTLETS AND LOCATIONS. o ,�#,,,
<br /> ED AIR CALLOUT ON VENDOR SHOP DRAWINGS. LOCATION LEVEL 4 1 ., a13. N2 IS USED FOR COMPRESS g TYPE SCROLL 410,BRANCH SIZE/ CW: IN 1 2/ LAB AIR COMPRESSOR/LAB AIR DRYER � fr tital-
<br /> (CONN SIZE) HW: IN - CAPACITY PK DEMAND. SCFM 50.4 'I' .
<br /> 20375
<br /> MARK LAC-1 SYSTEM: SCFM 201.6 ��joL.��'
<br /> DI: IN - MEDICAL AND LAB VACUUM PUMPS
<br /> RO: IN - LOCATION LEVEL 4 PRESSURE 100
<br /> DIRECT WASTE: IN - TYPE SCROLL MARK MVP-1 LVP-1 RECEIVER CAPACITY: GAL 240
<br /> INDIRECT DRAIN: IN
<br /> T` CAPACITY PK DEMAND: SCFM 25.2 LOCATION LEVEL 4 LEVEL 4 ELECTRICAL MOTOR HP (5) 15
<br /> STEAM: IN - SYSTEM: SCFM 25.2 TYPE CLAW CLAW MOTOR RPM 3,570, Date: NOVEMBER 03,2008
<br /> STEAM: PPHP
<br /> - CAPACITY FLOW: SCFM AT 19" 120 23 / /
<br /> RESSURE 50VOLT PHASE 460 3
<br /> CONDENSATE: IN - RPM 3,450 SYSTEM: SCFM AT 19" 360 23
<br /> UNIT WEIGHT WEIGHT: LBS 5,000 Job No: 580613.01
<br /> CA: IN
<br /> RECEIVER CAPACITY: GAL 80 RECEIVER CAPACITY: GAL 240 120 MAKE MANUFACTURER BEACON MEDAES Drawn By: CDi
<br /> -
<br /> VAC: IN - ELECTRICAL MOTOR HP (2) 7-1/2 ELECTRICAL MOTOR HP (4) 15 (2) 3 MODEL LPS-15P-SD240 Checked By: FJ
<br /> EXHAUST VENT: IN -
<br /> MOTOR RPM 3,450 VOLT/PHASE 460/3 460/3 NOTES [1, 2, 3, 4]
<br /> EXHAUST AIR: CFM - VOLT/PHASE 460/3 RPM 3,600 3,600 NOTES:
<br /> NOTES
<br /> UNIT WEIGHT WEIGHT: LBS 1,500 OPERATING WEIGHT WEIGHT: LBS 5,400 1,300 1. PENTAPLEX SYSTEM, CONTROL PANEL, NFPA 99 COMPLIANT, INTAKE MUFFLER. Drawing No.
<br /> NOTES: MAKE MANUFACTURER BECON MEDAES BASIS OF DESIGN MANUFACTURER BEACON MEDAES BEACON MEDAES 2. DESICCANT DRYERS, PREFILTERS, AFTER-FILTERS, REGULATORS,
<br /> 1. EQUIPMENT FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR EQUIPMENT DESCRIPTION. MODEL LPS-7D-SD80 MODEL LPV-15Q-H240-Q-V LTV-3D-H120 RELIEF VALVES, DEW POINT HYGROMETER, CO MONITOR, TEST PORTS,
<br /> 2. MOUNT WATER FILTER ASSEMBLY AND CONNECT TO WATER SUPPLY. NOTES [1] NOTES [1, 2, 3] [2, 3, 4] PREPACKAGED, SIZED FOR PENTAPLEX SYSTEM. NFPA 99 COMPLIANT.
<br /> 3. PIPE TO NEAREST FLOOR SINK. NOTES: NOTES: 3. MECHANICAL TO RUN ALL LOW VOLTAGE ALARM WIRING TO MASTER ALARM PANELS.
<br /> 4. PIPE TO FLOOR SINK. 1. DUPLEX UNIT WITH STARTERS, CONTROL PANEL, ALTERNATOR REFRIGERATED 1. QUADPLEX SYSTEM WITH CONTROL PANEL, NFPA COMPLIANT, EXHAUST MUFFER. 4. OPERATES ON EMERGENCY POWER. M 0•06
<br /> 5. PROIVDE HOSE CONNECTION TO STANDPIPE. DRYER AND AUTOMATIC DRAINS. PROVIDE CLASS 4 COALESCING AND 2. MECHANICAL TO RUN ALL LOW VOLTAGE ALARM WIRING TO MASTER ALARM PANELS.
<br /> 6. PROIVDE CONDENSATE DRAINS FROM EVAPORATOR COILS TO FLOOR SINK. PARTICULATE FILTERS. PROVIDE PRESSURE REDUCING STATION WITH AIR 3. OPERATES ON EMERGENCY POWER.
<br /> 7. CONNECT TO NEAREST AIR SUPPLY AT WASHER, TYPICAL EACH CONVEYOR. COMPRESSOR. 4. DUPLEX SYSTEM WITH CONTROL PANEL. SHEET ISSUED FOR REFEFEI\JcE
<br /> 8. RELOCATED EXISTING STEAM STERILIZER.
<br /> 2 1700 13th St-PGMC 2"a Floor Surgery-B1406-017
<br />
|