cu
<br /> la F.„
<br /> U L..)
<br /> Z
<br /> m
<br /> 9
<br /> W .-.........
<br /> SYMBOLS AND ABBREVIATIONS --„,
<br /> o ,,s...)
<br /> .4_
<br /> ,,, _.,
<br /> EXISTING NEW LIGHTING EXISTING NEW NURSE CALL SYSTEM EXISTING NEW
<br /> TELECOMMUNICATIONS SYSTEMS WORK DEFINITION
<br /> FLUORESCENT FIXTURE,DRAWN TO SCALE ON PLANS-LETTER IN FIXTURE o-, o--1 SINGLE BED STATION(PNC) V V TELECOMMUNICATIONS OUTLET x' ► FLAG NOTE <XIDENTIFICATION SYMBOL FOR EQUIPMENTt 0 ri,
<br /> ® INDICATES SWITCH LEG CONTROL NOTE WHERE NO QUANTITIES ADJACENT TO OUTLET INDICATES(3)RJ-45 JACKS WITH
<br /> CAT6 CABLES TO IDF VIA CABLE TRAY. /A\ REVISION SYMBOL """"""
<br /> ®-i ■--I TOILET EMERGENCY STATION(PNC) E5 ELECTRICAL DETAIL SYMBOL
<br /> 'o ' .--- . FLUORESCENT STRIP FIXTURE,DRAWN TO SCALE EXISTING WALLS ��
<br /> .—I .1-4 NURSE ASSIST BUTTON El ❑® FLUSH FLOOR OUTLET,TELECOMMUNICATIONS OUTLET AS ABOVE
<br /> { 0 0 CEILING MOUNTED DOWNUGHT FIXTURE � $ CORRIDOR UGHT-CEIUNG MOUNTED VX ®X TELECOMMUNICATIONS OUTLET AS ABOVE(X=#OF CAT6 CABLES) REMOVE EXISTING ELECTRICAL EQUIPMENT
<br /> • • PENDANT MOUNTED FIXTURE4: - w
<br /> W
<br /> -e; CORRIDOR LIGHT_CEIUNG MOUNTED V ®W TELECOMMUNICATIONS OUTLET-
<br /> WALLMOUNTED PHONE OUTLET AS ABOVE WITH(1)CAT6 CABLE
<br /> lQWALL MOUNTED FIXTURE Z AC AC ABBREVIATIONS
<br /> OH Q-I WALL MOUNTED FIXTURE EM al DUTY/STAFF STATION V V TELECOMMUNICATIONS OUTLET AS ABOVE((3)CAT6 CABLES),MOUNTED ABOVE COUNTER HEIGHT AC ABOVE COUNTER HEIGHT J-BOX JUNCTION BOX
<br /> CLG CLG AFF ABOVE FINISHED FLOOR LS LIFE SAFETY
<br /> 1] u RECESSED WALL MOUNTED FIXTURE ce EH CODE BLUE BUTTON(EMS) V V TELECOMMUNICATIONS OUTLET AS ABOVE((3)CAT6 CABLES),CEILING MOUNTED AG ABOVE GRADE MCC MOTOR CONTROL CENTER
<br /> dil m 'I m CEILING MOUNTED WALL WASHER EH ❑B-I BED COMMUNICATION INTERFACE VM ®M PATIENT MONITORING TELECOMMUNICATIONS OUTLET,(1)CAT6 CABLE. A,AMP AMPERE MDF MAIN DISTRIBUTION FRAME EVERETT,WASHNGTON
<br /> 5 AP ACCESS POINT-(FOR WIRELESS ANTENNA) MICRO,MW MICROWAVE
<br /> E-0 EQ RECESSED ACCENT LIGHTINGA❑ ❑A ANNUNCIATOR-DESK MOUNT D❑ F❑ TELECOMMUNICATIONS OUTLET FOR CAMERA TYPES:F,PTZ,AND C. (1)CAT6 CABLE ATS AUTOMATIC TRANSFER SWITCH MM MULTI-MODE Gu NS
<br /> ACCESSIBLE
<br /> UNDERCOUNTER TASK LIGHT MOUNTED BOX.COORDINATE FOR CAMFROM IDE W18.COILED SLACK LEFT N OF COILED SLACKLING WITH DIVI2B. IN SURFACE A/V AUDIO/VISUAL MID MOUNTED A-2 <�
<br /> MISCELLANEOUSAWG AMERICAN WIRE GAUGE N NEUTRAL
<br /> ®It iI I FIXTURE SUPPLIED FROM EMERGENCY CIRCUIT IT4 I REFER TO DESCRIPTION LISTED UNDER RECEPTACLES LEFT SIDE OF THIS SHEET.
<br /> MG.I MEDICAL GAS ALARM PANEL BLDG BUILDING NIC NOT IN CONTRACT ,zG F,....,
<br /> ® ® EXIT SIGN-DIRECTIONAL ARROWS AS INDICATED,SHADED SIDES ILLUMINATED I WAP I E. WIRELESS ACCESS POINT-(1)CAT6 CABLE BMS BUILDING MANAGEMENT SYSTEM NORM NORMAL
<br /> 4Pb 19' EMERGENCY BATTERY PACK I GRAP I GRAP GENERATOR REMOTE ALARM PANEL BOC BOTTOM OF CONDUIT OPOI OWNER PROVIDED OWNER INSTALLED
<br /> Eiji,u y 4,.... I CABLE TRAYBOT BOTTOM OF TRAY OPT OPTIONAL 1 ,,
<br /> o-® 0-. LIGHTING STANDARD-FIXTURE(S),POLE&BASE PUBLIC ADDRESS SYSTEM
<br /> ? `< ? 1 ' I! CABLE RUNWAY TYPE CABLE TRAY CAN COMMUNITY ACCESS TELEVISION PB PULLBOX '`JT ECUS
<br /> ® ® SITE UGHTING BOLLARD ®, 01 SPEAKER-FLUSH CEIUNG MOUNTED.NUMBER=ZONE C,CO CONDUIT,CONDUIT ONLY PNL PANEL
<br /> SPEAKER CABLE SHALL BE IN STEEL RACEWAYS WHERE IT IS ROUTED THROUGH AREA OF RESCUE INTERCOM SYSTEMS CB CIRCUIT BREAKER POS POINT OF SALE
<br /> e OR ® LIGHT FIXTURE TYPE-SEE FIXTURE SCHEDULE INACCESSIBLE CEILINGS BUT MAY BE OPEN CABLING IN ALL OTHER AREAS. Archkectire/Planning/tn.,Design
<br /> AOR AOR CCN CLOSET CIRCUIT TELEVISION PR PAIR Portland Seattle Los Angeles Washington DC
<br /> SWITCH-SINGLE POLE SUBSCRIPTS a,b,etc.,DENOTES CIRCUIT CONTROLLED
<br /> ®-i O-1 SPEAKER-AS ABOVE EXCEPT SURFACE MOUNTED V ® AREA OF RESCUE-STATION CKT CIRCUIT PTS PNEUMATIC TUBE SYSTEM
<br /> 3 3 AOR-A AOR-A 925 Fourth Ave.,Suite 2400
<br /> f t 3 WAY SWITCH Elivc; VOLUME CONTROLLER WALL MOUNTED AT+54"AFF.NUMBER=ZONE V V AREA
<br /> TO SHEET ANNUNCIATORNROOM
<br /> R S SWITCHBOARD OF EXISTING HOSPITAL CLG CEIUNG PTZ PAN-TILT-ZOOM
<br /> (REFERCM CEIUNG MOUNTED R,RO RACEWAY,RACEWAY ONLY Seattle,Washington 98104
<br /> 44
<br /> 4 WAY SWITCH OM ® CEILING MOUNTED MICROPHONE COMM COMMUNICATIONS RECEPT RECEPTACLE (PH)206 623 9414
<br /> K CR,CRIT CRITICAL REF REFRIGERATOR (FAX)206 623 7868
<br /> SWITCH-KEY OPERATED ACCESS CONTROL AND CCTV SYSTEMS CTB COMMUNICATIONS TERMINAL BOARD SLV SLEEVE
<br /> ,P $P SINGLE MODE
<br /> SWITCH-WITH PILOT LIGHT INTERCOM SYSTEMS ❑os os❑ consultants
<br /> th MAGNETIC DOOR SWITCH CU COPPER SM
<br /> CUP CENTRAL UTILITY PLANT SPECS SPECIFICATIONS
<br /> [1) DIMMER W> WD MASTER STATION-*WALL MOUNTED) Eil Ei2 SECURITY CONTROL PANEL
<br /> L� DDC DIRECT DIGITAL CONTROLS SW SWITCH LIFE SAFETY
<br /> $ i�
<br /> MOMENTARY CONTACT LOW VOLTAGE SWITCH S> sD SLAVE STATION cR EI CARD READER DED DEDICATED SWBD SWITCHBOARD ROLF JENSEN&ASSOCIATES
<br /> DL DOUBLE LUGS TBB TELECOMMUNICATIONS BONDING BACKBONE 19125 North Creek Parkway Ste 120
<br /> ® O RELAY-NEC CLASS II ®I Q, FLUSH CEILING INTERCOM STATION DOOR N0. ACCESS CONTROLLED DOOR TAG WITH DOOR AND CARD READER LOCATION Bothel,Washington 98011
<br /> DW DISHWASHER TELE TELEPHONE
<br /> ❑T 0 LOW VOLTAGE TRANSFORMER CIRCUITS CONTROLLED DOOR LOCATION
<br /> EQ EQUIPMENT TELECOM TELECOMMUNICATIONS CIVIL ENGINEER
<br /> 0 0 DURESS BUTTON-CONNECT TO ACCESS CONTROL SYSTEM ETC ELAPSED TIME CLOCK TGB TELECOMMUNICATIONS GROUNDING BUSBAR Magnusson Klemencic Associates
<br /> os os OCCUPANCY SENSOR \* .* RACEWAY CONCEALED IN CEIUNG OR WALL.HASH MARKS INDICATE NUMBER OF WIRES.112
<br /> e AWG WIRE UNLESS OTHERWISE NOTED.THREE WIRES IF NO HASH MARK SHOWN.LONG HASH Seattle,Washington 98101-2699
<br /> SWITCH-OCCUPANCY SENSOR MARK DENOTES NEUTRAL.—,INDICATES GROUND WIRE.EXPOSED RACEWAY IS ALLOWED ❑ 0 EWC ELECTRIC WATER COOLER TGMB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
<br /> DOOR RELEASE PUSHBUTTON FA FIRE ALARM TOC TOP OF CONDUIT 1301 Fifth Avenue,Suite 3200
<br /> ONLY WHERE NOTED.
<br /> FB FLOOR BOX TV TELEVISION LANDSCAPE ARCHITECT
<br /> Pc Pc SWITCH-PHOTO CELL CCTV CCTV CLOSED CIRCUIT N MONITOR PROVIDED BY OTHERS.INCLUDE OUTLET BOX WITH 1"RO TO FBOIC FURNISHED BY OTHERS,INSTALLED BY CONTRACTOR TYP TYPICAL
<br /> 4A EXISTING RACEWAY(IF HASH MARKS ARE SHOWN,PULL NEW CONDUCTORS) Tv1;1 ABOVE ACCESSIBLE CEIUNG. Site Workshop
<br /> Fl FILM ILLUMINATOR LION UNLESS OTHERWISE NOTED 927 Post Aley
<br /> RECEPTACLES - - - - RACEWAY BELOW SLAB OR UNDERGROUND FLR FLOOR UTP UNSHIELDED TWISTED PAIR Seattle,Washington 98101
<br /> CCN CAMERA-TYPES F AND PTZ-OUTLET BOX AT CAMERA LOCATON WITH 1"R AND
<br /> SINGLE RECEPTACLE 120V RACEWAY UP C= D❑ CATEGORY 6 PATCH CABLE TO NEAREST LOCATION ABOVE ACCESSIBLE CEIUNG.PROVIDE FO FIBER OPTICAL V VOLT OR VOICE-COMM
<br /> POWER CABLING PER DIVISION 28 PLANS AND SPECS.SEE DIVISION 27 FOR SURFACE STRUCTURAL ENGINEER
<br /> DUPLEX RECEPTACLE 120V MOUNTED CAT 6 BOX AND CABLING TO IDF.COORDINATE WITH DIVISION 27 FOR SURFACED FT FEED TRHU LUGS VCM VERTICAL CABLE MANAGER
<br /> RACEWAY DOWN MOUNTED BOX LOCATION. Magnusson Klemencic Associates
<br /> 0 411 G,GND GROUND VoIP VOICE OVER INTERNET PROTOCAL 1301 Fifth Avenue,Suite 3200
<br /> DUPLEX RECEPTACLE 120V,EMERGENCY CIRCUIT RACEWAY STUB-OUT WITH BUSHING FDD FD❑ FIXED CAMERA GD GARBAGE DISPOSAL VP VANDALPROOF Seattle,Washington 98101-2699
<br /> - dAC OAC DUPLEX RECEPTACLE 120V,MOUNTED 8"ABOVE COUNTER BACKSPLASH _ - GFCI GROUND FAULT CIRCUIT INTERRUPTER W WIRE,WIDTH,WALL OR WATT
<br /> - HOME RUN TO PANEL OR LOCATION NOTED PTZ, PT PAN-TILT-ZOOM CAMERA HCM HORIZONTAL CABLE MANAGER WAP WIRELESS ACCESS POINT MECHANICAL ENGINEER
<br /> HP HORSEPOWER WC WARMING CABINET CDi Engineers
<br /> ii% 4 DOUBLE DUPLEX RECEPTACLE 120V CIRCUIT CONTINUATION P P PROVISIONS FOR FUTURE CCN CAMERA-OUTLET BOX AT CAMERA LOCATION WITH 1"5 IDF INTERMEDIATE DISTRIBUTION FRAME WP WEATHERPROOF 4200 194th Street S.W,Suite200
<br /> lir ''� TO NEAREST LOCATION ABOVE ACCESSIBLE CEILING.
<br /> Lynnwood,Washington 98036 E
<br /> TWIST LOCK RECEPTACLE 120V JP JP JUNCTION BOX-POWER D❑ IH INSTA-HOT WATER DISPENSER XFMR TRANSFORMER hF
<br /> OPERATIONAL CCN CAMERA PROVIDED BY OTHERS.INCLUDE OUTLET BOX WITH 1"RO TO IRS INTERNAL RE-RADIATING SYSTEM 0 PHASE ELECTRICAL ENGINEER
<br /> °AC OAC DUPLEX RECEPTACLE 120V,EMERGENCY CIRCUIT,MOUNTED 8"ABOVE COUNTER BACKSPLASH ® �c JUNCTION BOX-LIGHTING OP OP SPARLING
<br /> DD D❑ ABOVE ACCESSIBLE CEILING.
<br /> 1,1P t
<br /> D D DOUBLE DUPLEX RECEPTACLE 120V,EMERGENCY CIRCUIT ® 0 JUNCTION BOX-COMMUNICATIONS 720 Olive Way,Suite 1400
<br /> (IP qp DUPLEX RECEPTACLE 120V,DEDICATED CIRCUIT C C CISCO OPERATIONAL CCN CAMERA.PROVIDED BY OTHERS.INCLUDE OUTLET BOX WITH 1" Seattle,Washington 98101-1853
<br /> JA JA JUNCTION BOX-AUDIO/VIDEO DD D❑ RO TO ABOVE ACCESSIBLE CEILING.
<br /> $ RECEPTACLE 208V OR 240V,SINGLE PHASE P B P B PULL BOX 5 OUTLET MOUNTING HEIGHTS GENERAL CONTRACTOR
<br /> 1111110 IL_ll_ll_ll MULTI-OUTLET ASSEMBLY M.A.Mortenson Company
<br /> SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR ON THE ARCHITECTURAL 14719 N.E.29th Place
<br /> O ® RECEPTACLE 480V,THREE PHASE DRAWINGS.IF SPECIAL OUTLET HEIGHTS ARE NOT SHOWN OR REQUIRED,THEN LOCATE OUTLETS AS Bellevue,Washington 98007
<br /> FIRE ALARM SYSTEM DOOR BUZZER SYSTEM NOTED BELOW.OUTLET HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE OF
<br /> Q ® RECEPTACLE 208V,THREE PHASE THE OUTLET UNLESS OTHERWISE NOTED.
<br /> ❑F 0 MANUAL STATION 0 0 PUSH BUTTON RECEPTACLES 18 INCHES(460mm)VERTICALLY MOUNTED
<br /> Revisions
<br /> COMBINATION RECEPTACLE 120/208V,120/240V,SINGLE PHASE
<br /> ,A 4, 4-
<br /> � 90 RECEPTACLE 208V,THREE PHASE(TWIST LOCK) ® ® SMOKE DETECTOR(D INDICATES INSTALLATION IN DUCT) 0 CI TRANSFORMER LIGHT SWITCHES 48 INCHES(1200mm)VERTICALLY MOUNTED
<br /> ' - RECEPTACLE 120/208V,SINGLE PHASE,TWIST-LOCK
<br /> ® ® HEAT DETECTOR(D INDICATES INSTALLATION IN DUCT) CE CO BUZZER AND VISUAL INDICATOR CLOCK OUTLET 80 INCHES(2030mm) DOCUMENT RELEASE 09 11/03/08
<br /> NE III FLUSH FLOOR OUTLET(DEVICES AS INDICATED) Ov 0 SPRINKLER VALVE POSITION MONITOR CONNECTION
<br /> CLOCK SYSTEM PANELBOARDS 72 INCHES(1830mm)TO TOP OF PANELBOARD DOCUMENT RELEASE 11 02/09/09
<br /> COMBINATION OUTLET-DOUBLE DUPLEX RECEPTACLE 120V,DISTRIBUTED TV CONNECTOR Fs Fs O ELAPSED TIME CLOCK
<br /> SPRINKLER FLOW SWITCH CONNECTION TELECOMMUNICATIONS OUTLET 18 INCHES(460mm)VERTICALLY MOUNTED DOCUMENT RELEASE 13 03/09/09
<br /> O
<br /> 061 Eal WITH COAX CABLE TO IDF AND RJ45 JACK WITH(1)CAT 6 TO IDE VIA CABLE TRAY.REFER DR16/ADDENDUM 3 04/06/09
<br /> TO DETAIL 3/E9.04. TS TS SPRINKLER TAMPER SWITCH ETC TELECOMMUNICATIONS OUTLET-WALL PHONE 48 INCHES(1370mm)VERTICALLY MOUNTED
<br /> � ® ELAPSED TIME CONTROLLER,+48 AFF UNLESS OTHERWISE NOTED A DOC.RELEASE 21 09/14/09
<br /> Sd S DUPLEX RECEPTACLE-SAFETY TYPE Q 0 FIRE ALARM SPEAKER-FLUSH CEILING MOUNTED AREA OF RESCUE-WALL STATION 48 INCHES(1370mm)VERTICALLY MOUNTED
<br /> DUPLEX RECEPTACLE-GROUND FAULT CIRCUIT INTERRUPTER TYPE W F
<br /> %El
<br /> FIRE ALARM SPEAKER-WALL MOUNTED A WORK PROPOSAL 103 05/26/11
<br /> G G ELECTRICAL RISER NURSE CALL DEVICE 48 INCHES(460mm)VERTICALLY MOUNTED
<br /> • CEILING DROP CORD �,, � FIRE ALARM SPEAKER&STROBE FIRE ALARM PULL STATION 48 INCHES(1200mm) CLOSEOUT DRAWINGS 04/02/12
<br /> --�`-,,L �'`.,P` FUSED SWITCH FIRE ALARM AUDIBLE NOTIFICATION BOTTOM EDGE SHALL BE AT 80 INCHES(2030mm)
<br /> F FIRE ALARM HORN/STROBE — �� CIRCUIT BREAKER DEVICES AFF OR 6 INCHES(150mm)BELOW CEILING HEIGHT,
<br /> EQUIPMENT
<br /> G G PANEL-208 VOLT SYSTEM WHICHEVER IS LOWER.
<br /> D F❑ FIRE ALARM HORN GF GF CIRCUIT BREAKER-GROUND FAULT PROTECTION 5
<br /> ////// PANEL-480 VOLT SYSTEM VISUAL ALARM LIGHT-WALL MOUNTED 4,---_,_ -<-S" DRAWOUT CIRCUIT BREAKER FIRE ALARM VISUAL AND COMBINATION BOTTOM EDGE SHALL BE AT 80 INCHES(2030mm)
<br /> FRCP FIRE ALARM CONTROL PANEL AUDIBLE/VISUAL NOTIFICATION DEVICES AFF OR 6 INCHES(150mm)BELOW CEILING HEIGHT,
<br /> ®� ®� EQUIPMENT CONNECTION,E=EMERGENCY POWER s2 DRAWOUT POWER CIRCUIT BREAKER-ANSI DEVICE 52 WHICHEVER IS LOWER
<br /> /d MOTOR CONNECTION SINGLE PHASE M❑ ❑M SMOKE DOOR RELEASE MECHANISM-(WALL MOUNTED MAGNETIC TYPE) • —_V_ CABLE TO BUS CONNECTION FIRE ALARM CONTROL PANEL 72 INCHES(1830mm)
<br /> /d MOTOR CONNECTION 3 PHASE O D SMOKE DOOR RELEASE MECHANISM-(COMBINATION DOOR CLOSER/HOLDER TYPE) —(-\__,— _C\j— FUSE OR CURRENT LIMITER CARD READERS 48 INCHES(1200MM)VERTICALLY MOUNTED
<br /> <I>`` POWER BUSWAY
<br /> FARA I FIRE ALARM REMOTE ANNUNCIATOR(FARA)
<br /> '�-� - — GROUND CONNECTION
<br /> 8 I II TRANSFORMER I FAGA I I FIRE ALARM GRAPHIC ANNUNCIATOR
<br /> XXX XXX
<br /> IDENTIFICATION SYMBOL FOR FEEDER SIZES Drawing Tide
<br /> Q Q SMOKE DAMPER CONNECTION
<br /> ® Q 1 F 1111—ROLLING DOOR RELEASE MECHANISM TRANSFORMER SYMBOLS AND
<br /> CONTROL ABBREVIATIONS
<br /> cM El FIRE ALARM CONTROL MODULE1:EEiTRANSFER SWITCH
<br /> D' EP FUSED SWITCH(FUSE RATING INDICATED) —0
<br /> MM MM FIRE ALARM MONITOR MODULE
<br /> LT ❑i DISCONNECT SWITCH OM O WATT-HOUR METER
<br /> [ a MANUAL STARTER O Nj AMMETER
<br /> Eli (' cg. COMBINATION MOTOR STARTER DISCONNECT SWITCH OV O VOLTMETER
<br /> Q
<br /> 0 ® ENCLOSED CIRCUIT BREAKER OG G ENGINE-GENERATOR
<br /> m ® O RELAY-CONTROL TYPE GI GI GROUND FAULT INDICATION ALARM
<br /> PUSH BUTTON CONTROL STATION pM I !I CUSTOMER OWNED POWER METER
<br /> o_ ElN It FP MULTI-FUNCTION PROTECTIVE DEVICE
<br /> H H AUTO DOOR PUSHPLATE
<br /> o
<br /> r, XXX > ( XXX > AVAILABLE SHORT CIRCUIT CURRENT
<br /> N
<br /> ‘CCI
<br /> 0
<br /> M
<br /> Date: NOVEMBER 03,2008
<br /> Q Job No: 580613.02
<br /> Drawn By: NUG
<br /> C9
<br /> o Checked By: MDI
<br /> 0
<br /> 0
<br /> 0
<br /> w
<br /> =I Drawing No.
<br /> 0
<br /> J
<br /> m
<br /> LL
<br /> Q E0.00
<br /> 1L
<br /> 0
<br /> FOR REFERENCE ONLY
<br /> Q
<br /> U
<br /> 1700 13'St-PGMC 2r'd Floor Surgery-B1406-017