} <br /> 7. WA State Energy Code requires the following: <br /> a. Below grade walls insulated to R-21 on interior or R-10 on exterior. <br /> b. R-15 insulation in 2x4 framing cavities of walls exposed during construction in <br /> existing living space. <br /> c. All new windows (including doors with more than 50% glazing)to be U-0.34 or <br /> less. <br /> d. R-10 rigid insulation at perimeter or slab-on-grade with R-10 thermal break. <br /> Show requirements on plans and sections/details. <br /> 8. Specify safety glass at hazardous locations as defined in Section R308.4 IRC. Show on <br /> plans. <br /> 9. Provide section at living room/deck showing how existing structure is supported to the <br /> foundation and that it is capable of supporting the additional weight of this proposed <br /> deck. (Also show in plan view how main floor is supported.) <br /> 10. Post/beam and post/footing connections call out an"EPC66" and"ABA66",respectively, <br /> but a 4x4 post is specified. Please correct. <br /> 11. Provide complete legal description on site plan and include all proposed"deck structures" <br /> in lot coverage. <br /> 12. The proposed deck on the site plan is considerably smaller than the proposed deck in the <br /> construction plans. Please correct plans and/or site plan to show the same structures. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> Jeff Heilman <br /> Development Technician <br /> 425-257-8976 <br /> Email:jheilman@ci.everett.wa.us <br /> r <br /> S:\1Common\ClericalUHeilman\CW1202-002(5929 Dexter Ave).doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.