Laserfiche WebLink
not exceed 5000 square feet. In this case the occupancy does not exceed <br />5000 square feet. <br />The separation required by code between M and S-1 occupancies has <br />been provided per T508.4 it is existing and is proposed to remain <br />unchanged. <br />No high -piled storage is planned or provided. <br />Occupant Load, Egress <br />1st Floor: <br />Ocupancy <br />Net sf <br />Occupant <br />Load <br />Factor <br />Occupant <br />Load <br />#or <br />exits/access <br />req'd <br />M <br />4340 <br />40 <br />109 <br />2 <br />S-1 <br />1 9221 <br />3001 <br />31 <br />1 <br />other* <br />589 <br />N/A <br />total <br />5851 <br />112 <br />2 exits required '/2 Diagonal apart or more: 51 ft <br />Actual distance from Main exit to 2nd :67ft therefore OK. <br />Egress will be improved by addition "this door to remain unlocked when <br />occupied", exterior walking surface will be improved from 2nd exit, Pavers <br />or concrete sidewalks will be provided. Additional exit signs will be <br />installed to city standards. Please advises us: does the city request Green <br />or Red lettering? <br />The existing doors are store doors (glass) with double keyed deadbolts for <br />security purposes. The main floor storage door has panic hardware. <br />Aisle spacing at clothing racks and book cases <br />Both side 44" Min <br />One side 36"Min <br />