Laserfiche WebLink
Occupant Load Egress Cont.: <br />2"d Floor: <br />Ocupancy <br />Net sf <br />Occupant <br />Load <br />Factor <br />Occupant <br />Load <br />#or <br />exits/access <br />req'd <br />B (Office) <br />200 <br />100 <br />2 <br />1 <br />S-1 <br />3700 <br />300 <br />121 <br />1 <br />other* <br />500 <br />N/A <br />total <br />4400 <br />112 <br />Two stairs exist, leading to the 2"d Zit. <br />y <br />==�:�P=oPos'=dto'be <br />haDue to security concerns one o the <br />blocked at the top and bottom in order to <br />prevent retail customers from mistakenly thinking that more retail occu <br />upstairs. no , <br />approximately 48" <br />wide, has handrails on each side 34-38" above the nosing, stairway <br />headroom is greater than 6'8" <br />Accessible Parking <br />The tenant has requested parking striping be provided by the owner, in <br />order to provide designated parking and Barrier free parking (Van and <br />Car) spaces and accessible route to the main door. <br />The tenant is requesting two spaces or county requirement whichever is <br />less located as near the main entrance of the Thrift Store as possible. <br />The 1" space, Van accessible + Aisle meeting ANSI A117.1 <br />The 2"d space if required, Car accessible + Aisle, meeting ANSI A117.1 <br />Signage shall be provided Min 5 Feet above paving and on the paving. <br />Accessible Bathroom: <br />The existing 2 restrooms do not fully comply with ANSI A117.1 full <br />compliance and would exceed 20% of the value of the improvements <br />however every effort will be made to improve accessibility and remove <br />barriers. <br />