Laserfiche WebLink
20C i <br /> / . <br /> D40 <br /> 4 <br /> S9.0 TYP' 2X10 _EDGER 'OP OUT <br /> /12 cv A OVE i <br /> S9.4I 6x6 POST&HO ABOVE ..- £ <br /> (3) 2x10 HDR r_J t I u u 5 c16SL FUR 'u u u u <br /> '�!• M®���-.rse. ~'®.-..rte- '�r ) e f <br /> 4: <br /> t6 -.erg.®- -. -.�®.- . .!.:f' <br /> 6X6--� - r 0 ►� 6X6 i <br /> o p <br /> c,II- 6X6 6X6 G`ABOVE ' 6 7 <br /> TRUSSES AT AlI o 59.0 59.0 `' ;` <br /> =i SEE ROOF 6 TYP. 24" O.C., TYP. > � 14, <br /> - <br /> t o FPMG. PLAN S9.0 I Q Q AT STEP <br /> GT ABOVE "� FOR WHICH w i g GT ABOVE - SEE �; <br /> SEE ROOF ci A'PLIES ' ®.T STEP EEII k, o'`V `,P>.„. c5 0 ROOF FRAMING `, <br /> FRMG. PLAN "I o 5 o x Co <br /> r, PLAN FOR WHICH <br /> FOR WHICH ® f X <br /> I " GT © _- 9 ' APPLIES <br /> APPLI S ' 1� ---- <br /> 1y. 1 - ADOLE N�,ri r§3 , t iI�,;' :z111,11111,11,110110 <br /> 3 .z <br /> MIDDLE FLOOR FRAMING '3e�#r4Pl fi SUtB <br /> likklond WeStnnat01 940 <br /> IT E3 B 8 E3 D MIDDLE LEVEL PLAN IT ELOWER FLOOR SHEAR [. ii2017 o <br /> 1 4"=1'-0" AT REAR POPOUT 1/4"=1'-0" AT REAR POPOUT kiNiCiiiiiNaftabi.04,11KOMomin <br /> SEE BLDG. PLAN WHERE OCCURS Ail SEE BLDG. PLAN WHERE OCCURS i ' V ` <br /> • 20Permit _ i s <br /> TJSB 18x7 D4 TJSB 12x7 ' <br /> 6x6 PORTAL PORTAL 5052 REGISTERED <br /> - '- '- i '- Y <br /> TTTT - - ARCHITECT <br /> 4 <br /> s0.0 TY. I Ex12 -B <br /> 12 20C I v, <br /> I D4 0 1 ROBERT E.WEIBLE <br /> 59.4 co GT {1BOVE - SEE <br /> co <br /> ROOF FRAMING PLAN 1 STATE OF WASHINGTON <br /> 2X10 _EDGER 4 FCR WHICH APPLIES 1 <br /> (3 2x 0 H11R 1 6X6 TRUSSES AT <br /> • 6X6 I4 --.y4 rj,, I ►�� (, 24" 0.C., TYP.�,i = _u _U _u 5YDc16_IEtSL HLDR -LJ , -L' -u <br /> 6 6X^ 1 AB�►VErd" � -...v�.�-� _--� -..� �;, <br /> o t'� �, <br /> _ E R i OF 6 TYP. t I 12.9 <br /> o G. "'LA S9.0 "$1 o .` I w <br /> GT ABOVE NI ,I' ICH Am TRUSSES AT ; il <br /> ' z 6 7 2x STRUC. o <br /> SEE ROOF N ci ."PLI1. S9.0 S9.0 w <br /> FRMG. PLAN T STEP �� FASCIA T, I -, _. <br /> I o 24 O.C., TYP. > AT STEP I X <br /> FOR WHICH 1 I w',I% ice- I I N <br /> APPLIES 59.0 I C° �t GT ABOVE - SEE ,,; <br /> ci) <br /> a> cv ROOF FRAMING 12 <br /> TYP. i � m o '• PLAN FOR WHICH S9.2 t.,.; <br /> cv GT ABOVE GT o+�x ' APPLIES <br /> TYP.Anh <br /> o SEE ROOF i �"A30 T N <br /> _ FRMG. PLAN "� Q w <br /> Mr o' 0 FOR WHICH I ,' 0 -F..,;:' <br /> N I APPLIES M t 0 <br /> �~ � o CMST12 11 i Q � <br /> DOUBLE CMST12 GT ABOVE CIHOLDO N- I x v <br /> 2x6 LEDGER cv STRAP-Lr-_'� <br /> ABObE <br /> AT LANDING, T� w <br /> STRAPS �� GT ABOVE Q `,� 4 <br />',' 1 CS1: W BLO�a % TYP. EA. END z I <br /> CO TIN OUS ,®`1 I CONT. 19' PSL 7x18 GT ABOVE ' <br /> 2x6 LEDGER TYP. ����-� <br /> -4X6 �`�) YP. 6x6 11.1 ®- I'• u DRU P BEAM -9.U5)U u O <br /> m �I ,u u u I' `.' <br /> n , r- -r 71 n ri ri ri ri 6 9-in n n °� _ <br /> CMST12 STRAP <br /> LANDING F.F. AT +8'-81/4"0.,w <br /> � :0 _�_ GLB 3�a'®115"®,SRO. BE__a -(_ _�, ,:,0 15 I 1I S9.2 S9.0; 3 HIPPED GARAGE y a <br /> -- r S9.2 ( ! (2)2 10 FBNIT3 ROOF FRAMING <br /> ABOVE MIDDLE FIN. FLR. N .1 S-AIR 'RMG. • 9 1 ,.( <br /> 296 AT 16 O.C. ��S9.01 1 I` o <br /> ^ I LANDING F.F. AT+7-0" I I 1/4"=1'-0" a <br /> (2) 2X10 !, ABOVE LOWER F0 <br /> .F. j I I o 0 ih <br /> l <br /> LEDGER , 0)2x6 FB 9 I x I <br /> AT LANSING <br /> 2x6 AT 16" O.C. I:_i\ <br /> \ STAIR FRMG.(2)2x1FB3\ LSL 13/4x14 LEDGER r-f � _ s <br /> S9.0 <br /> to <br /> S co \STNR/; P6} _ ! � a <br /> STS IR \ A- , <br /> I v <br /> RAISED / r\• _ 1 L______L......, 06 <br /> 11 0 \ <br /> lii <br /> J J <br /> PLATE \ LII \ z P6r 1 j i� �� 0 1 <br /> / \ <br /> / \ a 4x4 W ECC44 r o co <br /> \ (2)(2x10 FB (2) 2X10 D' _ / I I = r <br /> LANDING/POWDER #, / \ -)/ LLI o <br /> AT +1-23/4 t°;- -�.- - - . _ \ _ ' N ® r- <br /> ABV. MIDDLE F.F. . GL 5%a x 12 NOR - j + 1® I p (L/ <br /> S t .:11....:::::.::::::::::::::::::'''.1'/ <br /> 6x6 _I <br /> 1'-' ca < <br /> o RAISED FLOOR S o CC66 Ill <br /> N',.:::° .: (DOT FILL) o •-ALIGN LNDEP • "j 2x STRUC. m� I <br />' RAISED FLOOR T ....•.�°_.°'. EDGE OF FASCIA <br /> SEE BELOW -tea- � I '-'-I I� (1)Ili <br /> (DOT FILL) ,°,x.:::::......,,,,... c5 WINDOW ABOVE 5' !� ® U <br /> SEE BELOW /''...:-::::::',..;::::.:',..-::::.- 9,` o :� 12 �' i x m B <br /> GT ABOVE .°. :::;;P2x10=906 - s S9.2 i I' ® !` Z } <br /> SEE ROOF 7 "'` . _--- en OD-1i ____i < o <br /> FRMG. PLAN s' r <br /> TR I I I <br /> , TRUSSES AT <br /> FOR WHICH '�°°e° ,°<• ,i o GT ABOVE POST UP m° • g r 24" 0.C., TYP. Il I I 6x10 FB Cl 0 <br /> 7, SEE I <br /> APPLIES �d a..°.,, °` FRMG.ROOF __J <br /> GT ABOVE] ez GT ABOVE c. _ -. p� I Z <br /> O��.°°.n°..m.° °�Y FOR WHICH I xr �, (SEE ROOF BA48 HANGER <br /> ti 6 6 POST UP - E <br /> �`. ' :,,,: • ,ki° _ ' FRMG. PLAN 1.. - - <br /> • 6X6 --,44;;.;,,,;,.;-.7,,,,, A APPLIES POST 6x6 GL 5%a x 10%z FB 1 <br /> FOR WHICH W/ECCQ I g .. _ <br /> {2) 2X10 HDR, I' ' ABOVE� I.f,p x�4��® - F 6X6') x10 HDR __ �F ��a� �� APPLIES, TYP. 5 6 � --J a H <br /> 2 _ <br /> 0 v' HDU14--i---'74-;: "**�• .. <� OTHER SIDE & - <br /> • - _ - - 13 ; o 1, I REAR END OF MGU5.25/SDS 4x4 W/ECC05-4 T <br /> 7 (3) 2x10 HDR S9.2 I 'I mI UNIT) 12 <br /> I 1--• <br /> o� r <br /> S9.2 2x STRUC. FASCIA -� L I RUSSES 24"0.0 'SI ,I ---- S9.2 <br /> 6x6 W/ECCQ (ri �I FACE-NAIL "1"i <br /> 5-6 -EL ---------_ >/ RAFTER TO C <br /> UPPER FLOOR FRAMING 2x ROOF FRAMING I 6x10 FBSIDE , <br /> AT 24UNIT E3A St E3C "O.C. ,�'� �; POP-OUT HIPPED PORCH <br /> MIDDLE FLOOR SHEAR BA610 HANGER UNIT 3ROOF FRAMING <br /> 1/4"=1'-0" ® ilall 6x6 W/ACE6 1/4"=1'-0" SEE ELEV. IF/WHERE APPLIES 0. <br /> (2)2x10 FB '� 'I ® ® ® a$ <br /> TOP AT+11'-0" (3)2x + %4" PL WD I MIDDLE FLOOR FRAMING MEMa,) 0. <br /> 1UNDER (2)2x10 L____.. UNITE3ii LOWER FLOOR SHEAR > <br /> PLATE +9'-0"-I• <br /> I <br /> RAISED PLATE ,,T n r3 - .2 0 <br /> +10'-23/4" , I (2)2x10 FB <br /> - <br /> o; TOP AT+10'-1" ' I- t - Cr) C '�'r <br /> FLOOR FRAMING NOTES 2': - 14.75 _ " <br /> .I, �- STEP __ _ (3)2x + �/4" PLYWD. N <br /> TOP OF JSTS N,z,, ,�_ ' I UNDER (2)2x10 0mow 3 <br /> SF STRUCTURAL FASCIA (5/4 x 8) FRAMING DIRECTION AT+11'-0" ^_� <br /> ,§ 2x10 AT 16"OC it 1 <br /> EDGE OF 2x10 1 I <br /> ` 1 14" LEDGER: SUBFLOOR I ( 14.75" <br /> FB FLUSH BEAM ,.,k," . TJI RIM-JOIST BENEATH i , STEP <br /> • EDGE OF 2x10 �. - 1 » I \ 15Cisi) ,.., 0 <br /> SUBFLOOR ;\, ,I TOP AT+11-0 1 r 14" JI RIM JOIST SHEAR WALL NOTES W Z <br /> HDR HEADER a EXTENT OF FRAMING BENEATH • �_ '- > <br /> \I �I UPPER FLOOR WALLS TOP OF JSTS I :< .,. F::m:Y: W L <br /> GT GIRDER TRUSS \1 �- I I AT+10'-1" r _1 - <- ,.. "Roo- <br /> I <br /> ;S, I't 14.75" I 14" T11 1 ; MIND'E FLOOR WALLS SHEAR WALL TYPE <br /> ill 0) <br /> GLB GLU-LAMINATED BEAM (SEE SHEET S1.0 (SEC. 06185) I STEP 13 I A 16"00 I,i 0 SEE S1.2 FOR NAILING SHEAR WALL WITH FORCE •C <br /> FOR CAMBER INFO.) f\ c 59.2 I TRANSFER AROUND WINDOW <br /> FLOOR JOISTS ARE TYPICALLY RAISED PLATE �, 'I t .�f 114.75" SEE 8/S1.3 0 <br /> 2x10 AT 16" 0.0. +10'-23/4" a I i PLATE +8'-1"--1-, ,- 1 I STEP 0 <br /> ® (2) 2x STUDS UNO BY X9, WHERE X=NUMBER OF STUDS U.N.O \\.��'� ry-.`��_ y�� PLATE AT 14" LEDGER: __ - I -HDXX HOEDOWN TYPE - SEE S1.3 FOR SCHEDULE W. <br /> 8 I +9'-0" TA RIM-JOIST1 I Fl "r"' <br /> / <br /> HANGERS INDICATED ARE SIMPSON STRONG-TIE S9.2 TOP AT+10'-1" i _ 1 L. THE WOOD SHEATHING DIAPHRAGM SHALL BE APPLIED <br /> 7 1 TO SAME SIDE OF STUD WALL AS SHEAR WALL TAG <br /> RAISED PLATE <br /> FLOOR SHEATHING SHALL BE AS INDICATED ON SHEET S1.0. T S9.2 PLATE +8'-1" AND SHALL CONTINUE ABOVE AND BENEATH OPENINGS. <br /> +10'-23/4" 12 <br /> ALL BEAMS AND HEADERS SHALL BE SUPPORTED ON DOUBLE VENT DUCTING S9.2 SOME SHEAR WALLS REQUIRE 3x PLATES AT THE <br /> STUDS UNLESS NOTED OTHERWISE. PROVIDE 3 BUNDLED STUDS FOUNDATION OR AT ABUTTING PANELS. SEE - Job No.: 13-47 <br /> UNDER BEAMS GREATER THAN 6" WIDE AND 2 BUNDLED STUDS SHEARWALL TABLE SHEET S1.2. U <br /> UNDER BEAMS LESS THAN 6" WIDE. FACE NAIL BUNDLED STUDS RAISED UPPER FLOOR RAISED MIDDLE FLOOR , Sheet No.: <br /> TOGETHER WITH (2) 16d AT 12" O.C. TYPICAL. SEE SHEET S1.2 FOR TYPICAL SHEARWALL DETAILS <br /> ® FRAMING PLAN ' , FRAMING PLAN 2 <br /> SEE SHEETS S9.0 & S9.1 FOR TYPICAL WOOD FRAMING DETAILS. 1/4"=1'-0" TECH ROOM 1/4"=1'-0" POWDER ROOM AND STAIR LANDING '` <br /> Sheet Order: A B U F R E S D <br />