Laserfiche WebLink
o r���o�� D <br /> �' , <br /> SNOHOMISH DEC Y 2 2014 <br /> HE �LTH DISTRICT PUBLIC WORKS <br /> WWW.SNOHD.ORG Environmental Health Division <br /> December 16, 2074 ' , � <br /> 11;', �a -a3 <br /> Domenic Baker <br /> 14718 58'"Ave S <br /> Tukwila, WA 98i68 <br /> Subject: Proposed Remodel of Wienerschitzel, 5905 Everareen Way, Everett <br /> Dear Mr. Baker: <br /> Your plans have been received; however, the plans cannot be approved as submitted. The following information <br /> is needed �7f10f�^ fU!tilerplan revie:v: <br /> 1. It is unclear from the plans submittzd whzther or not thz thr=_=-compartme�t sink has integral drainbcards at <br /> each end. Three-compartment sinks must have integral drainboards at ezch end. This must be shown on the <br /> floor plan. <br /> 2. No separation is indicat=d beh,veen the food preparation sink(Item;15) and the three-compartment sink (Item <br /> �25) A horizontal separation of at 1=ast 16 inches or a pony wall, from the floor to at least 16 inches above the <br /> sink basin, is required between the food preparation sink and the three-compartment sink. The type of separation <br /> used must be shown on the floor plan. The oniy acceptable option to the pony wall, other than the 16 inch <br /> horizontal separation, is the use of a partition of at least 1%inch in thickness(similar to lhe partitions in restroom <br /> stallc) trom the floor to at least �6 inches above the sink basin of a material that is wateroroof. If this option is <br /> used, it must also be shown on the fioor plan along with an accurate description of the material to used and <br /> method used for installing and securing lhe this partilion. <br /> 3. No separation is indicated between the handwash sink (Item �24) and the three-compartment sink (Item #25). <br /> A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required behveen the <br /> handwash sink and the three-compartment sink. This must be shown on the floor plan. <br /> 4. No separation is indicated on the fioor plan behveen the handwash sink Qtem#24) and the grill (Item#8). A <br /> horizontal separation of at le2st 16 inches or a vertical partition 16 inches in height is required beriveen the <br /> handwash sink item and grill item. This must be shown on the floor plan. <br /> 5. Due to Items»5 and n6 above, splashguards�viil likely be installed on both sides of the handwash sink. When <br /> splashguards (equipment, partitions and/or walls) are provided on both sides cf a handwash sink, the disiance <br /> between the splashguards must be at least 18 inches apart(shoulder widlh) to allow proper access to the <br /> handwash sink. This must be shown on the floor plan. <br /> 6. No manufacturer name was submired for the non-heat treated ice cream machine dual hopper(Item#13). The <br /> manufacturer name for this equipment must be submitted <br /> 7. No manufacturer name and model number v+as submitted for the food preparetior sink (Item#15) and the reach- <br /> in freezer Qtem m17). The manufacWrer names and model numbers £or this equipment must be submitted. <br /> 8. Food service establishments wanting to continue operation during a remodel m��st submil written <br /> documentation stating the procedures that will be used to ensure food sa(ety during the remodel. The <br /> documentation must include the following: <br /> a) Where and how handwash facilities will be set up. <br /> b) What methods will be used for maintaining proper temperatures of all potentially hazardous foods. <br /> c) Where produce will be prepared. <br /> d) Where dishv+ashing will occur. <br /> e) What procedures will be followed if interruptions in water, power or sewaae disposal occur. <br /> � What type of dust barriers will be used and where will they be used. <br /> g) A floor plan of any temporary f�od oreparation areas. <br /> i <br /> 30?0 Rucker Avenue, Suite 104 � Evereit. WA 98201-3900 � tel: 425.339.5250 � fax: 425.339.5254 � <br /> � <br />