My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7407 EVERGREEN WAY BOSTON CHICKEN 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
7407
>
BOSTON CHICKEN
>
7407 EVERGREEN WAY BOSTON CHICKEN 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2018 11:42:32 AM
Creation date
10/17/2018 11:40:55 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7407
Tenant Name
BOSTON CHICKEN
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
mP�GHA (���Z <br />f <br />O n = <br />1a <br />Pg <br />`��Nc �cM�4 <br />Gordon Witcher <br />City of Everett <br />Building Department <br />3200 Cedar Sveet <br />Everett, WA 98201 <br />CIVIL ENGINEERING, LANO PLANNING. SURVEYING, EI:VIRONMENiA� SERVICES <br />November 16, 1994 <br />D ���Od� O <br />NQV 171991 <br />...._ ......................................................... <br />CITY 0� EVERETT <br />�I({. PMfMt ODU11te► <br />RE: Proposed Boston Chicken Located at 7407 Evergreen Way, Everett, Washington <br />Our Job No. 5184 <br />Dear Gordon: <br />Enclosed are two sets of revised civil engineering plans for the above-referenced project. The enclosed <br />plans have been revised in accordance with redline comments (which are also enclosed) received from your <br />office. These revisions include the follawing: <br />L A handrail has been added along lhe biofiltraGon swale to offer addiUonal protecfion for <br />pedestrians walking along Ihe existing sidewalk on Evergreen Way. <br />2. We have provided a detail on Sheet C6 for the handicap ramp located near the southwest <br />building corner. <br />3. We have added two signs near the handicap parking sta1L This information is actually <br />detailed on the Architectural Site Plan SP1. However, appropriate referencing of the signs <br />is included on the grading and storm drainage plan. <br />4. A detail has been added to Sheet C6 illustradng the plant material specified within the <br />proposed biofiltraaon swale. <br />5. The propc,sed water meter has been revised from a 1�h-inch water meter to a 2-inch meter. <br />6. The concrete retaining wall specified along the east property boundary will be constructed <br />during il�e earlier stages of conswcuon before ihe site has been cleared of all asphalt and <br />vegetaUon. The scope of work and disturbance of property necessary to install the wall <br />will be minor in nature. We do not foresee adverse impacts wi�h respect to erosion or <br />disturbance to �he adjacent property. Once the retaining wall has been constructed, other <br />portions of ihe site would be exposed and prepared for furthe.r eartlnvork. Consequently, <br />the concrete retaining wall would provide a barrie� between tl�e adjacent properties and the <br />on-site construcdon acfivity. Hence, addiuonal erosion control along the east property <br />boundary would not be necessary. <br />7. Computations for the sizing of the orifce wilhin Ilie restrictor plate are attached. These <br />computations were in the original submittal of tl�e storm drainage report. <br />18215 72ND AVENUE SOUTH KENT, JJA98032 (206) 251-6222 (206) 251-0782 FAX <br />
The URL can be used to link to this page
Your browser does not support the video tag.