My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7600 EVERGREEN WAY EVERETT CLINIC 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
7600
>
EVERETT CLINIC
>
7600 EVERGREEN WAY EVERETT CLINIC 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2018 3:28:06 PM
Creation date
10/17/2018 3:17:29 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7600
Tenant Name
EVERETT CLINIC
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
208
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dimensions have been added tn ihe p/an at Vestibu/es 131 <br />and 168. Vestibu/e 167 has been e/iminated and rep/aced <br />with /arge� Vestibu/e #168. See sheet A2.1. <br />6. The pull side dimension on door 138A should be shown as <br />minimum 18 inches, and the landing should be dimensioned as five <br />feet deep on the drawings, per ICC/ANSI A117.1 — 2003 section <br />404.2.3.1 (a). New detai/ IS/A5.1 contains rhis information, <br />7. The approach to the latch side of the toilet compartment door <br />should be shown as minimum 42 inch minimum width on the <br />drawings, per ICC/ANSI A117.1— 2003 section 604.8.3. <br />Dimensions ha ve been added to En/arged F/ovr P/an <br />Z/A2,1. <br />8. The flush control on the water closet should be shown on the wide <br />side of the accessible stall, per ICC/ANSI AS17.1— 2003 section <br />604.6. E/evation 1/A� 1 has been revised to show this <br />condition. <br />4. The length of the side horizontal grab bar in the accessible toilet <br />stall should be shown as minimum 4� inches on the drawings, per <br />ICC/ANSI A117.1— 2003 section 604.5.1. Dimensions have <br />been added to e%vations 1/A7,1 and 2/A7,1. <br />10. The drawings should indicate a note for in�ulation required at the <br />water supply and drain piFes under the lavatories, per ICC/ANSI <br />A117.1— 2003 section 606.6. This note is shown on detai/ <br />19/A6.i. <br />Energy <br />1. The insulation, glazing and R-value at new doors and exterior envelope <br />should be shown on the drawings to meet the minimum requirements <br />to comply with the 2009 Washington State Energy Code. R-va/ues <br />for exterior enve%pe infiJ/ a�e indicaied on detai/s 2/A5.1, <br />3/A5,1 and 11/A5.1. Donr 138A has been �evised to a new <br />door with a Max. U-factor 0,60 as �equired by the 2009 <br />Washington State Energy Lode. Refer to updated Door <br />Schedu/e on s/ieetA9.1. <br />Please notify us immediately if you require any additional information to review <br />and approve this permit applicacion. <br />��i <br />
The URL can be used to link to this page
Your browser does not support the video tag.