My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8609 EVERGREEN WAY COMMUNITY HEALTH CENTER 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
8609
>
COMMUNITY HEALTH CENTER
>
8609 EVERGREEN WAY COMMUNITY HEALTH CENTER 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2018 11:59:31 AM
Creation date
10/25/2018 11:57:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8609
Tenant Name
COMMUNITY HEALTH CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7. I�irc Alarm Svstcm - An appro��c� automatic lirc dctccti�m s�'stcro sht�ll bc pro��i�lr�l ,is <br /> rcyuired by City Ordinance No. 1)02-92, Chapter 16.7G, uf q�c Everett Nlunicipal Code. <br /> Plans for such system shell be submitted to the Fire Marshai for revie�v and approval prior <br /> to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropria[e trip tests, �vitnessed by a Fire Dcpartment inspector, shall bc performed, along <br /> �viih a certificate of completion, prior to final acceptance of the system. Fire alarm <br /> sysicros shall he installed according to NPPA Standard 72. I�istallation oP fire alarm <br /> components, including basic �r•iring, may not commence before plans are �PP�'��'«� �'1' <br /> thc Firc Department Plnn Reviewer. Pire alarm Jra�vings must hc profcssionall�� <br /> reudcrcd, in sufficient detail, and must he internally consistcnt. Riser diagrams must match <br /> installation plans and load calculations. Components must be listed and approved for usc <br /> togclher. Changes to plans must include new drawings and calculations and nmst he <br /> approved by the Fire DeparUnent Plan Rcviewer prior to installation. Fire alarm <br /> insiallation is subject to fielJ inspection by a Fire Department Inspector. An approved set <br /> of plans and �2e Building Department electrical permit must be present for any installation <br /> inspection. Fire alarm systems shall be installed under permit of the Ciry oF Gverett <br /> 13uilding Department. Glectrical inspections and approval are required prior to calling for <br /> ;icceptanee tests. Call (425) 257-8810 for permit information. The absenee of «•nrkin�; <br /> phonc lines for lhc nlarm syslent will be cause for pustponin� Tirc dcpartmcnl <br /> iuspectiou and testing nnd shnll result i�i denial of occup�uc�. <br /> R I�irc Su�ression fSprinkler) Svstem - An approveJ automatic �u�,prc�si��n sy�tcin sh:ill hr <br /> pro��ided as req�ired by City Ordinance No. 1902-92, Chapter 16.7G, of the Evercu <br /> �tunicipal Code. The system must include a mechnnicol water gong bell. Plans for an} <br /> such system shall be submitted to the Building Department for examination and approval. <br /> Sucli plans shall include plans for the underground mains that will supply the sprinkler <br /> sysicm. The type of sprinklcr to be installed �vill be determined by the Building Official. <br /> 1( may be an NFPA 13, NFPA 13R, or NFPA 13D system depending upon several factors. <br /> Spriuklcr inslnllation shall not begin witiiout m� approved and stumped set oP pinns <br /> from the Building Department. The Fire Derarunent will also review the plans and shall <br /> I ield inspect Ure installation based only on approved plans that must be on site. Changes to <br /> plans must be approveJ by both the Building and Fire Departments. AbovegrounQ <br /> sprinkler piping shall be hydrostatically tested as established in NFPA Standard 13. <br /> Underground piping shatl be hydrostatically tested and flusheJ as established in NFPr\ <br /> Standard 24 for private fire mains. IBelow-arow�d aipine must Ue instnlled b� <br /> �V��shineton State Patrol Licensed UnderBround Snrinkler line certified "U" installers. <br /> For further information, contact lhe Stnte Fire Marslinl's Of6ce at (3G0) 570-3134 or <br /> contact the Gverett Fire Department at (425) 257-R125.) All such tests shall br <br /> witnessed by a Fire Department inspector. Call (425) 257-8124 to make an appointmcm <br /> for inspection. Contractors' materials and test certiticates shall be submitted to the Everett <br /> Pire Department priur n� issu;uicr uf :mti Certific;ues �,f Occup:�nc� . Call I-G'-i) ?i7-S12� <br /> for more informati�m. <br /> 9. ('unstruction and dcnwlitiun u( huil�ings shull hc in cnm��li:mcc ���ith dic prc��isions ui thc <br /> ZOU3 Inlcm�rti�ie.il I�ire Codc. ('h,iptcr ld. <br /> ��- ------- _. ___--- <br />
The URL can be used to link to this page
Your browser does not support the video tag.