Laserfiche WebLink
{� � <br /> / � <br /> Plan Check No. B60475 <br /> October 26, 1998 <br /> Page 2 of 2 <br /> 6. A detail for the lateral bracing with compression struu should be shown for the suspended <br /> ceiling. UBC Standazd 25-2, Table 25-A <br /> Accessibility <br /> 1. The 60" minimum diameter unobstructed floor space should be shown within the <br /> (employee's) toilet room per Section 1106.11.2. Note that the lockers appeaz to encroach into <br /> thatspace. <br /> 2. The 18" minimum side cleazance, for 60" perpendicular to the employee's bathroom from the <br /> pull side should be shown. Section 1106.103, item 1 <br /> Energy <br /> 1. The exhaust extension ducts should be shown on the plans (maximum of 10' in length) for <br /> each repair stall. The connected offices and restrooms should be supplied with conditioned air <br /> under positive pressure. Section 304.1, VIAQ <br /> 2. The walls between heated and unheated spaces should be shown as insulated (R-11 for gas) <br /> with a vapor barrier. Section 1130 <br /> Prepare a response letter showing where each item in this correction letter is addressed on the plan <br /> set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure that <br /> the proposed structure will be conswcted in compliance with all adopted codes. <br /> Sincerely, /� <br /> � ":� � <br /> y I.ee . .� <br /> Associate Engineer ' `"^� <br /> � <br /> �� �F <br /> �� , <br /> k�,_��, �.., , <br /> TL:jWnl�Pkk.211 xg ' .. <br /> r � <br /> !.: <br /> �:1 Z^ „' <br /> ni'.. <br />