My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 MAPLE ST EVERETT SELF STORAGE 2018-01-01 MF Import
>
Address Records
>
MAPLE ST
>
2727
>
EVERETT SELF STORAGE
>
2727 MAPLE ST EVERETT SELF STORAGE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2018 2:35:49 PM
Creation date
11/13/2018 2:32:11 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2727
Tenant Name
EVERETT SELF STORAGE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20. Fire flow requirements for this structure are 2,000 gpm. <br /> 21. An approved automatic suppression system sh all be provided as required by City <br /> Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for ar.; ..uch system must be submitted to the Suilding Department and the <br /> Everett Fire Lepartment for examination and approval. Such plans must include <br /> plans for the underground mains that will supply the sprinkler system. <br /> Aboveground sprinkler piping must be hydrostatically tested as established in <br /> NFPA Standard 13. Underground piping must be hydrostatically tested and <br /> flushed as established in NFPS Standard 24 for private fire mains. All such tests <br /> must be witnessed by a Fire Department inspector. Call 425-257-8123 to make <br /> an appointment for inspection. <br /> Contractors' materials and test certificates must be submitted to the Everett Fire <br /> Department prior to issuance of any Certificates of Occupancy. <br /> Call 425-257-8123 for more information. <br /> 22. An approved automatic fire detection system shall be provided as required by <br /> City Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. <br /> Plans for any such system must be submitted to the Fire Marshal for review and <br /> approval prior to installation. Submittal shall include cut sheets of all equipment <br /> intended for use. Appropriate trip tests, witnessed by a Fire Department <br /> Inspector, shall be performed, along with a certificate of completion, prior to final <br /> acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Standard 72. <br /> Fire alarm systems shall be installed under permit of the City Building <br /> Department. Electrical inspections and approval are requirad prior to calling for <br /> acceptance tests. Call 425-257-8810 for pormit information. <br /> 23. Standpipes shall be installed per Sections 9U4.5 and 904.6 of the UBC. , <br /> 24. A portable fire extinguisher with a minimum UL rating of 2A:10-B:C must be <br /> provided within 75 feet travel distance on each floor of all portions of each <br /> building during construction and prior to occupancy. <br /> 25. Fire lanes must be provided as required in Everett Municipal Code 46.44. Fire <br /> lanes must be ���entified by red curbs with white stenciling stating "NO PARKING <br /> - FIRE LAN�" and ��ertical signs stating "NO PARKING - FIRE LANE -TOW <br /> AWAY Z01JE:' Location must be approved by the Fire Marshai. I <br /> 26. The premiss� must be clearly identified by address at the street entry. Each ', <br /> buiiding must be clearly identified so as to be visible and legible from the access ;, <br /> road. Each suite must be cleariy identified so as to be visible and legible from <br /> the access road. I <br /> 27. When access to or within a structure or an area is unduly difficult because of <br /> secured openinys or where immediate access is necessary for life saving or fire- <br />