Laserfiche WebLink
.. , �• <br /> � � <br /> �� � � od �� �,�, <br /> 21 Sept 1998 SEP 211�8 B�oce E BlacAme�,PIA <br /> ,�1 Dols 5 0rx4ie.AI4 <br /> CITY O��VERETT' e����� c�a�,mo�,AiA <br /> Cclln R. one�,AIA <br /> Mr.Tony Lee Permit Services " `'�`'K'"�.n'" <br /> Associate Engineer "`°�"� r`'`N°" "'� <br /> City of Everett, Public Wo�ks B`•�'�„A N,��� ,p�, <br /> \15II�;im M.Pploh��G AIA <br /> 3200 Cedar Street A � �_ 's�� �� 4�A <br /> Everett,WA 98201 �,.,,,_,v� s� �. n�n <br /> RE: Everett Self Storage,2727 Maple Street, Plan Check No. B 59621 <br /> Response to Cortection requested, Letter dated 9/4/98 <br /> Dear Mr. Lee, <br /> This letter is a point by point response to your letter dated 9/4/98 and dxumentation of our <br /> discussion on 9/9/98 conceming your letter. Thank you for expediting your review comments. <br /> Attached are two complete new sets of drawings reflecting the corrections requested. <br /> NON STRUCTURAL <br /> General <br /> 1. We concur when using Area Separation Walls(ASV1�the yards for this building <br /> would be based o�only two side separation and a 1.Sx allowable factor for the area <br /> increase. In order comply with the maximum 54,000 sq. ft. maximum we have move <br /> the ASW to grid line J. This revision allows for less than 54,000 sq. ft.on the east <br /> building the larger of the two. See the revised floor plans and the revised allowable <br /> area calculation on A-0.1. <br /> 2. Mechanical rooms, elevators, and stairs were not used in the revised area <br /> calculations on sheet A-0.1. <br /> 3. Per our discussion on 9/9198 you agreed this parapet wall is not required,due to <br /> exception#4 in UBC section 709.4.1,which allows for no parapet wall if the roof is <br /> comptetely of non combustible construction,as is our roof assembly. <br /> 4. A UL listed smoke detector will be placed at each elevator door that when activated <br /> w�ll prevent the door from opening and recall the elevator to the respective loading <br /> dock floor. (First floor on the west building, Basement level on the east floor. See <br /> flcor plan notes. <br /> Occupancy , <br /> 1. The office is a B occupany, the cover sheet has been revised. <br /> 2. As you have noted, the office occupancy is less than 25%of the storage o�:cupancy, <br /> theretor we will not provide an occupancy separation. See the floor plan revisions. <br /> 3. Per our discussion on 9/9198, our mini storage use does not hmclion like a <br /> conventional warehouse occupancy. The maximum number of employezs will not <br /> exceed 4 and the customers that visit the site do not arrive in significant numbers �" �� ^ <br /> . :..�,.,�,��.1;�t����: <br /> simultaneously to warrant separate sex washrooms. As I noted, I have been involved <br /> in the design of many multi-story mini storage facilities and have never been subject aaoi s,.�a nM�� <br /> to this interpretation. A uni-sex toilet is consistentwith the code requirements in sw�e,aos <br /> ���,wa�n����o� <br /> Section 2902.3 paragraph 1 for B and S occupancies with less than 4 empioyees. veiz� �a3z <br /> IEl 206-h11�A52P <br /> FAti 70tr441-791' <br />