My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3120 MCDOUGALL AVE COMMERCIAL OFFICE FOR ROBERTS 2018-01-01 MF Import
>
Address Records
>
MCDOUGALL AVE
>
3120
>
COMMERCIAL OFFICE FOR ROBERTS
>
3120 MCDOUGALL AVE COMMERCIAL OFFICE FOR ROBERTS 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2018 9:15:11 AM
Creation date
11/14/2018 8:54:06 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
3120
Tenant Name
COMMERCIAL OFFICE FOR ROBERTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br />� <br />✓7. The west stairway is required to be enclosed as specified in Section 1009. Openings into the <br />enclosure must be ono-hour rated and the ceiling separating the mechanical equipment must <br />have 5/8"gwb un both sides of framing. <br />�8. Walls and ceilings of corridors (lobby 102 & lobby 202) are required to be of 1 hour fire- <br />resistive construc6on. Secdon 1005.7. An archite�tural secdon through the comdor is <br />necessary to determine how this is accomplished. The walls and doors of toilet rooms, offices <br />and conference rcams must be one-hour rdted with 20 min. doors. The closet in lobby 202 is <br />not allowed. <br />�9. Interior openings inro corridors are required to be protected as set forth in Sec6on 1005.8. <br />Self-closing or automatic closing twenty-minute rat�i door assemblies properly gasketed <br />should be provided. Other openings are limited to 3/4-HR rated fixed glazing and shall not <br />ezcced 25 Yb of the azea of the common wall. <br />t�0. The mech/jan. room 216 cannot open into the stair enclosure. Sec. 1009.3. <br />✓ 11. Twenty minute rated doors are allowed 1296 sq. inches of wire glazecl opening mazimum. <br />Door type B appears to exceed this requirement. Sec. 713.7. <br />�2. Stairs must have sloped, closed risers per sec. 1106.9. <br />✓13. Provide hanging and seismic restraint details for light covers shown on detail 9/A-6. <br />� 14. Provide span raGng information fo�� corrugated panels proposed for the entry canopy. <br />V 15. Provide seismic restraint details for suspended ceiling areas. <br />Y 16. Provide engineering c,alculations for rookeries over 4'-0" high. <br />�17. Provide guardrails adjacent to walking surfaces if grade is more than 30 inches below. <br />�18. Provide U=.90 max. window glazing. <br />[/ 19. Provide U=.60 max. for exterior doors (unglazed). <br />�20. Below grade walls must be insulated to R-11 minimum (slab insulation need not eztend <br />horizontally as shown). <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.