My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3120 MCDOUGALL AVE COMMERCIAL OFFICE FOR ROBERTS 2018-01-01 MF Import
>
Address Records
>
MCDOUGALL AVE
>
3120
>
COMMERCIAL OFFICE FOR ROBERTS
>
3120 MCDOUGALL AVE COMMERCIAL OFFICE FOR ROBERTS 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2018 9:15:11 AM
Creation date
11/14/2018 8:54:06 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
3120
Tenant Name
COMMERCIAL OFFICE FOR ROBERTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�k <br />• See note on architecturalsheet SP-1. <br />17. Provide guardrails adjacent to waiking surfaces if grade is more than 30 inches <br />below. <br />• See note on architectural sheet SP-1. <br />18. Provide U=.90 max. window glazing. <br />• Glazing specified does not exceed .90 "U" value. <br />19. Provide U=.60 max. for exterior doors lunglazedi. <br />• Exterior doors do not exceed the .60 "U" value for an unglazed door. <br />20. Below grade walis must be insulated to R-11 minimum (slab insulation need <br />not extend horizontally as shown►. <br />• See architectural sheets A-1 and A-?.. <br />21. Provide bracing for soffit walls. <br />• See architecturalsheet A-5. <br />22. Accessible doors shall have maneuvering clearances per Section 1106.10.3. <br />This item applies to door No's 110, 111, 210, 211, 101 & 102C. <br />• See architecturalsheets A-1, A-2 and A-5. <br />23. On any floor where water fountains are provided, at least 50 percent, but in <br />no case less than on e shall comply with Section 1106.13. Section 1105.4.1. <br />At least once water fountain shall ��e mounted at the standard height (40"- <br />44"). <br />• See architecturalsheet A-5. <br />24. Controls, operating mechanisms and hardware shall be accessible in <br />accordance with Section 1106.3. <br />• See interior eievations on A-5. Compliance with section 1106.3 is <br />indicated in the finish hardware and electrical specifications. <br />25. Alarm system shall inciude both audible and visual alarms and shall be located <br />per Section 1105.4.9. <br />• See response to comment �t1. <br />26. One in every eight accessibie parking stalls, but not less than one parking stall, <br />shall comply with the van parkirg space requirements in Section 1107.1.5. <br />• See architectura� sheet SP-1 and civii sheet 1. <br />27. Accessible parking stalls are required per Table No. 11-F and Section <br />1107.1.1. <br />
The URL can be used to link to this page
Your browser does not support the video tag.