My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3120 MCDOUGALL AVE COMMERCIAL OFFICE FOR ROBERTS 2018-01-01 MF Import
>
Address Records
>
MCDOUGALL AVE
>
3120
>
COMMERCIAL OFFICE FOR ROBERTS
>
3120 MCDOUGALL AVE COMMERCIAL OFFICE FOR ROBERTS 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2018 9:15:11 AM
Creation date
11/14/2018 8:54:06 AM
Metadata
Fields
Template:
Address Document
Street Name
MCDOUGALL AVE
Street Number
3120
Tenant Name
COMMERCIAL OFFICE FOR ROBERTS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• See drawing revisions on cover sheet. <br />7. The west stairway is equired to be enclosed as specified in Section 1009. <br />Openings into the enc�osure must be one-hour rated and the ceiling separating <br />the mechanical equipment must have 5/8" gwb on both sides of framing. <br />• See architecturalsheets A-4 and A-5. <br />8. Walls and ceilings of corridors (lobby 102 & lobby 202) are required to be of 1 <br />hour fire-resistiv:� �onstruction. Section 1005.7. An architectural section <br />through the cor� ',r is necessary to determine how this is accomplished. The <br />walls and doors c� toilet rooms, offices and conference rooms must be one- <br />hour rated with 20 min. doors. The closet in lobby 202 is not allowed. <br />• See architecturalsheets A-2, A-4 and A-5. <br />9. Interior openings into corridors are required to be protected as set forth in <br />Section 1005.8. Self-closing or automatic closing twenty-minute rated door <br />assembiies properly gasketed should be provided. Other openings are limited <br />to 3/4-HR rated fixed giazing and shall not exceed 25% of the area of the <br />common wall. <br />• See architectural sheet A-4 for rated doors. Door hardware shall comply <br />with section 1005.8 as indicated in the specifications. <br />1�J. The mech/jan. room 216 can not open into the stair enciosure. Sec. 1009.3. <br />• See architectural sheets A• 1 and A-2. <br />11. Twenty minute rated doors are allowed 1296 sq. inches of wire glazed <br />opening maximum. Door type B appears to exceed this requirement. Sec. <br />713.7. <br />• See architectural sheet A-4 and attached fire rated glazing specification. <br />12. Stairs must have sloped, closed risers per sec. 1106.9. <br />• See architectural sheet A-6. <br />13. Provide hanging and seismic restraint details for light covers shown on detail <br />9/A-6. <br />• See architectural sheet A-6. <br />14. Provide span rating information tor corrugated panels proposed for the entry <br />canopy. <br />• See attached informational sheet. <br />15. Provide seismic restrairit details for suspended ceiling areas. <br />• See architecturai sheet A-5. <br />16. Provide engineering calculations for rockeries over 4'-0" high. <br />
The URL can be used to link to this page
Your browser does not support the video tag.