• See drawing revisions on cover sheet. <br />7. The west stairway is equired to be enclosed as specified in Section 1009. <br />Openings into the enc�osure must be one-hour rated and the ceiling separating <br />the mechanical equipment must have 5/8" gwb on both sides of framing. <br />• See architecturalsheets A-4 and A-5. <br />8. Walls and ceilings of corridors (lobby 102 & lobby 202) are required to be of 1 <br />hour fire-resistiv:� �onstruction. Section 1005.7. An architectural section <br />through the cor� ',r is necessary to determine how this is accomplished. The <br />walls and doors c� toilet rooms, offices and conference rooms must be one- <br />hour rated with 20 min. doors. The closet in lobby 202 is not allowed. <br />• See architecturalsheets A-2, A-4 and A-5. <br />9. Interior openings into corridors are required to be protected as set forth in <br />Section 1005.8. Self-closing or automatic closing twenty-minute rated door <br />assembiies properly gasketed should be provided. Other openings are limited <br />to 3/4-HR rated fixed giazing and shall not exceed 25% of the area of the <br />common wall. <br />• See architectural sheet A-4 for rated doors. Door hardware shall comply <br />with section 1005.8 as indicated in the specifications. <br />1�J. The mech/jan. room 216 can not open into the stair enciosure. Sec. 1009.3. <br />• See architectural sheets A• 1 and A-2. <br />11. Twenty minute rated doors are allowed 1296 sq. inches of wire glazed <br />opening maximum. Door type B appears to exceed this requirement. Sec. <br />713.7. <br />• See architectural sheet A-4 and attached fire rated glazing specification. <br />12. Stairs must have sloped, closed risers per sec. 1106.9. <br />• See architectural sheet A-6. <br />13. Provide hanging and seismic restraint details for light covers shown on detail <br />9/A-6. <br />• See architectural sheet A-6. <br />14. Provide span rating information tor corrugated panels proposed for the entry <br />canopy. <br />• See attached informational sheet. <br />15. Provide seismic restrairit details for suspended ceiling areas. <br />• See architecturai sheet A-5. <br />16. Provide engineering calculations for rockeries over 4'-0" high. <br />