My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 N BROADWAY EVCC 2018-01-01 MF Import
>
Address Records
>
N BROADWAY
>
1010
>
EVCC
>
1010 N BROADWAY EVCC 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2018 8:55:30 AM
Creation date
12/4/2018 8:55:07 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
EVCC
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
283
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED LIBERTY HALL,EVERETT COMMUNITY COLLEGE Everett,Washington <br /> deposits within Zones II through IV, and/or (3) a 2-foot gravel pad following ground improvement <br /> using GeoPiersTM within Zones III and IV. <br /> The allowable bearing pressures presented in each section below apply to the total dead and <br /> long-term live loads and may be increased up to one-third for short-term live loads such as wind or <br /> seismic forces. <br /> The ddsign frost depth for the Puget Sound area is 12 inches; therefore, we recommend that <br /> exterior footings for the building be founded at least 18 inches below lowest adjacent finished <br /> grade. Interior footings should be founded at least 12 inches below bottom of slab or adjacent <br /> finished grade. For shallow foundation support, we recommend widths of at least 24 and <br /> 36 inches, respectively, for continuous wall and isolated column footings supporting the proposed <br /> building. <br /> Foundation Design-Zone I <br /> For foundations bearing on competent undisturbed dense to very dense glacial soils within Zone I, <br /> .the foundations may be designed using an allowable soil bearing pressure of 6,000 pounds per <br /> square foot(psf)for isolated spread footings and continuous footings. The depth to dense glacial <br /> soils is summarized in Table 1. If existing fill,compressible silt or clay,or unsuitable native soil are <br /> observed at the foundation bearing elevation for footings designed for 6,000 psf bearing pressure, <br /> we recommend that the contractor remove the material and backfill with lean concrete or control <br /> density fill (CDF) having a design strength of at least 200 pounds per square inch (psi). If the <br /> foundations within Zone I are designed for 4,000 psf or lower,the overexcavation (if required) may <br /> be backfilled with properly compacted imported gravel borrow. <br /> Partial Overexcavation and Replacement-Zones II through IV <br /> Supporting the building on shallow spread footings will require removing the upper portion of <br /> undocumented fill and compressible silt/clay soils from below the footings within Zones II through <br /> IV and replacing these materials with properly compacted imported structural fill. This method of <br /> partial overexcavation and replacement with structural fill will mitigate the risk associated with <br /> excessive settlement under the building. <br /> We recommend that the building foundations be overexcavated in Zones II through IV as described <br /> in Table 3 below and shown in Figure 3. The lightly loaded perimeter footings should be <br /> overexcavated by at least 11 feet. The concrete slabs-on-grade should also be supported on at <br /> least a 1.5 foot thick pad of structural fill below the capillary break layer. The overexcavated zones <br /> below the building foundations should be backfilled with imported structural fill such as Gravel <br /> Borrow per WSDOT Standard Specification 9-03.14. Removal of the existing fill and silt/clay soils <br /> should extend beyond the edges of the building foundations a distance equal to the depth of the <br /> excavation below planned foundations. The overexcavation can be neat-cut below the footing if <br /> lean concrete or CDF is used as backfill. <br /> Page 12 I June 10,2010 I GeoEngineers,Inc. <br /> File No.5836.010.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.