My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3232 OAKES AVE BAKER LEWIS SCHWISOW LAW 2018-01-01 MF Import
>
Address Records
>
OAKES AVE
>
3232
>
BAKER LEWIS SCHWISOW LAW
>
3232 OAKES AVE BAKER LEWIS SCHWISOW LAW 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2018 10:52:32 AM
Creation date
12/6/2018 10:35:18 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3232
Tenant Name
BAKER LEWIS SCHWISOW LAW
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a. Previous correction: A rated shaft enclosure is required at the stainvay connecting the <br /> three stories in the change of occupancy from a single family residence to a commercial <br /> structure, per IFC section 4603.3.2. Opening protectives, horizontal and verti�al fire- <br /> reted tested assemblies, hourly separation required, continuity, termination of the <br /> enclosure at top and bottom should be shown on the drawings, per IBC chapter 7. <br /> ��4, Exit door 03 from the stair enclosure is required to have a clear width of 32 inclies, per IBC <br /> section 1008.1.1. <br /> a. Previous correction: The minimum size all nevJ or relocated doors should be shown on <br /> the schedule as minimum 2'-10"wide, 6'-8" high, per IBC section 1008.1.1. <br /> � 5. A landing is required on either side of the doors into the exit stairs, per IBC section 1008.1.5. <br /> Construction <br /> 1. Rated assemblies at the stairs (reference detail 3 on sheet A3) should be shown and targeted <br /> � as details on the drawings, in addition to referencing the reted assembly number. <br /> , 2, Doors in rated enclosures should be shown as rated, per IBC table 7?5.4. <br /> 3. Please specify hardware for poor 06 which does not require tight grasping, tight pinching, or <br /> - twisting, per IBC section 1008.9.1. <br /> a. Previous correction: The hardware set for the accessible entrance door should be shown <br /> on tl�� drewings, per IBC section 1008.9.1 <br /> _ 2. Is there a door planned for Bath 106 in the basement? The existing door is shown as removed. <br /> 3. Previous correction: Handrails should be detailed in section, per IBC section 1012. <br /> 4. Stoves and other fi�ures should be shown in the existing kitchen. <br /> Accessibility <br /> 1. The dimensions of the van accessib�e parking stall and access aisle do not correspond to the <br /> drawing of the stall and access aisle. Please clarify on the drawing that the overall dimension of <br /> the parking area is 16'-0" or greater, and that t(ie dimensions of the van accessible parking <br /> space and access aisle meet the minimum requirements, per IBC section 3411.4.2 (4). <br /> 2. The location of the van accessible signage should be shown on the drawings, per IBC section <br /> 3411.4.2 (3). <br /> 3. The length of the van accessible stall is not dimensioned on the drew�ings. By scale, the length <br /> of the van accessible parking space does not appear to cemply with the requirements of City of <br /> Everett Design and Construction Standard Drawing 3346. Please verify with the civil consultant. <br /> 4. Please provide a section through the threshold connecting the basement hall with the exterior <br /> access aisle. A Floor or landing should be shown at the same elevation on either side of the <br /> door, per IBC section 1008,1.5. <br /> a. Previous correction: An ac.cessible building entrance should be shown on the drawings, <br /> per IBC section 3411.4.2 (i). <br /> 5. The drewings should indicate the marking of the access aisle for the van accessible space. <br />
The URL can be used to link to this page
Your browser does not support the video tag.