My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 7TH FLOOR 2018-01-01 MF Import
>
Address Records
>
PACIFIC AVE
>
916
>
7TH FLOOR
>
916 PACIFIC AVE 7TH FLOOR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2018 9:53:18 AM
Creation date
12/11/2018 2:19:51 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
7TH FLOOR
Notes
SLEEP LAB / MIDWIFERY
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Raymond Cre�and, Adniinistrator <br /> Prog�am, Plans 3 Specifications <br /> CCRS /90369-1546-003 <br /> /90317-1546-004 <br /> April 26, 1990 <br /> Pepe 3 <br /> 21. Please describe how pre-nature infants will be accomn�odated. MAC 248-18- <br /> 615(3) <br /> 22. Please indicate function and fixture requir�eiaents for handwash and <br /> qorminp erea. MAC 248-18-615(d) <br /> MECHANICAL CONSULTANT'S REVIEM <br /> Claude V. LaNs, P,E. 753-3489 <br /> t�ECNANICAL ITFIAS: <br /> 1. Provide nitrous oxide end Naste yas evacuation outlets in C-section 741 <br /> the sa�e as is required for a delivery rooa. NAC 248-18-719 Table 719-2. <br /> 2. Please correct floor plan backyround on shcet M-3 to apree with arehitec- <br /> tural floor plan on sheet A-1. Include service sinks in rooms 744 and <br /> 758e as shoNn on sheet A-1. <br /> 3. Sinks in nursery 742 a�ust be equipped Nith knee or foot controlled <br /> faucets, or equivalent. WAC 248-18-616(6)(a) <br /> 4. Verify thet pipiny and medical yes outlet bozes in 2-ho�r fire Nall do <br /> not violate 1988 UBC section 4306(e). <br /> 5. Mhere is note 11 referrcd to by sysbol on floor plen shorm on sheet M-3? <br /> 6. Please ve�lfy that the ne►v fuel otl storaye tank detail on sheet M-2 <br /> •eets EPA rcquirea�ents: <br /> 7. Provide hu�idity control for C-section 747 and nursery 742. NAC 248-718- <br /> )19(2)(p)(1)(B) and (2)(p)(ii) <br /> 8. Indicate a�ount of atr supplied to roons by existiny induction units. If <br /> total exceeds 190 CFM per roa� ezhaust or pressure reifefs mey De <br /> required to yet rid of excess pressuro. <br /> 9. Provide coa�bination fin da�npers and motorized saake da�npers at all duct <br /> 3e5etrations of 2-hour con�part�nentation Nall. 1988 NFPA 101 section 6- <br /> 10. fire deapers are required in 24 x 12 duct at wall between nunery 742 and <br /> corridor 738, in 12 x 8 du�t in wal? between office 700 and corridor 762, <br /> and in 14 x 8 duct in wall betNeen nursery 742 and nurse station 7422. <br /> 1988 UBC section 4306 <br />
The URL can be used to link to this page
Your browser does not support the video tag.