My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2929 PINE ST COCOON HOUSE 2018-01-02 MF Import
>
Address Records
>
PINE ST
>
2929
>
COCOON HOUSE
>
2929 PINE ST COCOON HOUSE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 8:46:55 AM
Creation date
12/20/2018 10:34:18 AM
Metadata
Fields
Template:
Address Document
Street Name
PINE ST
Street Number
2929
Tenant Name
COCOON HOUSE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A sprinkler system complying with UBC Standard 38-1 and/or <br />NFPA Standard 13 must be provided. <br />Plans for any such system must be submitted to the Building <br />Department and the Everett Fire Department for examination <br />and approval. Such plans must include plans for the <br />underground mains that will supply the sprinkler system. <br />As of January, 1991, sprinkler system permits are issued by <br />the Building Department. Plan review fees are assessed by <br />the Building Department. No fee is assessed by the Fire <br />Department. <br />Above ground sprinkler piping must be hydrostatically tested <br />as established in NFPA Standard 13. Underground piping must <br />be hydrostatically tested and flushed as established in NFPS <br />Standard 24 for private fire mains. All such tests must be <br />witnessed by a Fire Department inspector. Call 259-8710 to <br />make an appointment for inspection. <br />Contractors' materials and test certificates must be <br />submitted to the Everett Fire Department prior to issuance <br />of any Certificates of Occupancy. <br />Call 259-8726 for more information. <br />6. An approved automatic fire detection system must be provided <br />as required by Chapter 16.76 of the Everett Municipal Code. <br />Plans for such system must be submitted to the Fire Marshal <br />for review and approval prior to installation. Submittal <br />shall include cut sheets of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department <br />inspector, must be performed prior to final acceptance of <br />the system. <br />Fire alarm systems must be installed under permit of the <br />City of Everett Building Department. Electrical inspections <br />and approval are required prior to calling for acceptance <br />tests. Call 259-8810 for permit information. <br />7. A portable fire extinguisher with a minimum UL rating of 2A <br />must be provided within 75 feet travel distance on each <br />floor of all portions of each building during construction. <br />8. The premises must be clearly identified by address at the <br />street entry. Each building must be clearly identified so <br />as to be visible and legible from the access road. Each <br />unit must be clearly identified so as to be visible and <br />legible from the access road. <br />
The URL can be used to link to this page
Your browser does not support the video tag.